{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T02:56:10Z","timestamp":1761101770226},"reference-count":20,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T00:00:00Z","timestamp":1151452800000},"content-version":"vor","delay-in-days":2279,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2000,4]]},"abstract":"<jats:p>Safety and tolerability of a one\u2010step tilt table test with high dose (5 \u03bcg\/min) isoproterenol (ISO) without intermediate stages were evaluated in a symptomatic population of 300 patients referred for clinical syncope, near syncope, or dizziness. ISO has been used as a provocative test but remains controversial. A population of 118 male and 182 female patients with a mean age of 45 (range 5\u201390) years underwent 300 tests. Heart rate and blood pressure were monitored continuously. A positive test was one in which clinical symptoms were reproduced or hemodynamic criteria met. Patients were initially supine for 5 minutes followed by head upright tilt (HUT) to an angle of 80\u00b1 for 10 minutes. Negative tests were repeated with an infusion of ISO at a rate of 5 \u03bcg\/min, HUT was positive in 133 (44.3%) of 300 tests. With a 10\u2010minute HUT alone, only 17 (5.7%) of 300 of tests were positive. Of the initial negative tests, 273 of 283 were tested with ISO. With ISO, 116(42.5%) of 273 were positive. ISO in high dose (5 \u03bcg\/min) was used in 264 of 273 patients, while low dose (1.0\u20132.5 \u03bcg\/min) was used in 9 of 273 under special circumstances. High dose ISO was tolerated in 164 (62.1 %) of 264 patients, reduced in 87 (33%) of 264, and discontinued in 11 (4.2 %) of 264. Reasons for reduction included tachycardia (40 patients), nausea (31 patients), chest pain (2 patients), arrhythmia (5 patients), or other (9 patients). Adverse effects resolved within 1 minute of dose reduction. This one\u2010step high dose ISO protocol reproduced neurocardiogenic syncope in symptomatic patients who tested negative without ISO and was safe, tolerated, and expeditious.<\/jats:p>","DOI":"10.1111\/j.1540-8159.2000.tb00824.x","type":"journal-article","created":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T15:28:41Z","timestamp":1151508521000},"page":"441-445","source":"Crossref","is-referenced-by-count":4,"title":["Safety and Tolerability of an Aggressive Tilt Table Test Protocol in the Evaluation of Patients with Suspected Neurocardiogenic Syncope"],"prefix":"10.1111","volume":"23","author":[{"given":"STEPHEN C.","family":"VLAY","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CRAIG","family":"BRODSKY","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LINDA C.","family":"VLAY","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,28]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb04074.x"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(91)90714-K"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198902093200603"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.eurheartj.a059906"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-116-5-358"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)90790-6"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-5415.1992.tb01801.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(93)90029-9"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90824-K"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)90542-K"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-8703(07)80027-5"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-118-12-199306150-00005"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.92.1.54"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(99)80079-4"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb03921.x"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(96)00236-7"},{"key":"e_1_2_1_18_2","first-page":"77","volume-title":"A Practical Approach to Cardiac Arrhythmias","author":"Vlay SC.","year":"1996"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb03904.x"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.93.5.973"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb03565.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2000.tb00824.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2000.tb00824.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T10:26:20Z","timestamp":1698575180000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2000.tb00824.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,4]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2000,4]]}},"alternative-id":["10.1111\/j.1540-8159.2000.tb00824.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2000.tb00824.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,4]]}}}