{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T06:40:57Z","timestamp":1698734457775},"reference-count":19,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T00:00:00Z","timestamp":1151452800000},"content-version":"vor","delay-in-days":2279,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2000,4]]},"abstract":"<jats:p>Adequate atrial lead performance consists of stable sensing and pacing properties. To evaluate whether the CPI 4269 bipolar lead, covered with mannitol (Sweet Tip), in the atrial position encounters these properties, we performed a prospective study of this lead. After complete dissolution of the mannitol helix, mapping of the atrium to obtain the highest electrogram and lowest threshold was followed by screw\u2010in into the endocardium. Intraoperative measurements were performed and long\u2010term follow\u2010up was scheduled every 6 to 12 months to measure threshold and perform an intracardial electro\u2010gram. Between February 1993 and December 1996, a total number of 73 leads in the atrial position in a consecutive series of patients was implanted. Implantation was performed in 28 patients receiving an AAIR and 45 patients a DDDR pacemaker. Reason for pacemaker implantation was a third\u2010degree AV block in 37% of patients, type II second\u2010degree AV block in 25%, sick sinus syndrome in 35%, and drug refractory paroxysmal atrial fibrillation following His\u2010bundle ablation in 3%. The intraoperative bipolar atrial electrogram had a mean voltage of 4.25 \u00b1 2.1 mV. The acute atrial bipolar threshold was 0.63 \u00b1 0.43 V, and current was 1.35 \u00b1 0.81 mA at a 1.0\u2010ms pulse duration. The mean acute resistance of the lead was 572 \u00b1 86 Ohm. After a mean follow\u2010up of 18.3 months, the bipolar intracardial electrogram was 3.37 \u00b1 2.00 mV, the mean atrial threshold measured at the last outpatient clinic visit was 0.99 \u00b1 0.74 V and the mean impedance was 640 \u00b1127 Ohm. A sensing problem due to traction of the atrial lead occurred in only one patient. Acute and late dislodgement did not occur. The CPI 4269 (Sweet Tip) lead is manufactured with a dissolvable capsule covering the helix tip electrode, permitting a safe passage through the venous system. This interim analysis shows that this lead in the atrial position has favorable acute and chronic results.<\/jats:p>","DOI":"10.1111\/j.1540-8159.2000.tb00834.x","type":"journal-article","created":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T15:28:41Z","timestamp":1151508521000},"page":"499-503","source":"Crossref","is-referenced-by-count":4,"title":["Successful Results of a Bipolar Active Fixation Lead for Atrial Application: An Interim Analysis"],"prefix":"10.1111","volume":"23","author":[{"given":"EUGENE M.","family":"BUYS","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"NORBERT M.","family":"VAN HEMEL","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"EMILE R.","family":"JESSURUN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"BARBARA","family":"FOOT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JOHANNES C.","family":"KELDER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JO J.A.M.","family":"DEFAUW","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,28]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb04983.x"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199804163381602"},{"key":"e_1_2_1_4_2","first-page":"133","volume-title":"New Perspectives in Cardiac Pacing. 2","author":"Mond HG.","year":"1901"},{"key":"e_1_2_1_5_2","first-page":"69","volume-title":"Clinical Cardiac Pacing","author":"Mond HG","year":"1995"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb02378.x"},{"key":"e_1_2_1_7_2","first-page":"99","article-title":"The clinical performance of three designs of atrial pacing loads from a single manufacturer; The value of steroid elution","volume":"6","author":"Hua W","year":"1996","journal-title":"Eur JPE"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb01471.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1995.tb06981.x"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1989.tb05049.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb01168.x"},{"key":"e_1_2_1_12_2","first-page":"534","article-title":"A comparison of acute and chronic characteristics of active and passive fixation atrial leads, (abstract)","volume":"11","author":"Sheehan AM","year":"1988","journal-title":"PACE"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-4804(71)90032-1"},{"key":"e_1_2_1_14_2","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/S0022-5223(19)40179-7","article-title":"The significance of electrode surface area and stimulating thresholds in permanent cardiac pacing","volume":"71","author":"Smyth NPD","year":"1976","journal-title":"J Thorac Cardiovase Surg"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0033-0620(81)90025-6"},{"key":"e_1_2_1_16_2","first-page":"749","article-title":"The effect of electrode surface texture and steroid on stimulation, (abstract)","volume":"10","author":"Stokes K.","year":"1987","journal-title":"PAGE"},{"key":"e_1_2_1_17_2","first-page":"33","volume-title":"Modern Cardiac Pacing","author":"Stokes K","year":"1985"},{"key":"e_1_2_1_18_2","first-page":"2038","article-title":"Efficient or waste full? A comparison of an active and a passive fixation lead","volume":"17","author":"Snoeck J","year":"1994","journal-title":"PAGE"},{"key":"e_1_2_1_19_2","first-page":"95","article-title":"The electrode tissue\u2010interface: The revolutionary role of steroid elution","volume":"15","author":"Mond HG","year":"1992","journal-title":"PAGE"},{"key":"e_1_2_1_20_2","unstructured":"Physicians manual META \u00b1 DDDR models 1250 1250H or 1254.Telectronics Pacing Systems Englewood Co USA."}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2000.tb00834.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2000.tb00834.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T10:26:16Z","timestamp":1698575176000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2000.tb00834.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,4]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2000,4]]}},"alternative-id":["10.1111\/j.1540-8159.2000.tb00834.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2000.tb00834.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,4]]}}}