{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,21]],"date-time":"2025-09-21T17:00:33Z","timestamp":1758474033454},"reference-count":27,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T00:00:00Z","timestamp":1151452800000},"content-version":"vor","delay-in-days":2249,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2000,5]]},"abstract":"<jats:p>Implantation of single lead VDD pacemakers is an established therapeutic option in patients with AV block and normal sinus node function. However, related to occurrence of sinus node disease and atrial undersensing, there is concern whether VDD devices are appropriate in physically active young patients. Two hundred thirty\u2010two consecutive patients with isolated A V block and VDD pacemakers were investigated. This population was subdivided into quartiles of 58 patients according to age at time of inclusion: 26.2\u201359.4 years (group A), 59.5\u201370.1 years (group B), 70.2\u201381.0 years (group C), and 81.1\u201392.5 years (group D). Follow\u2010up visits included pacemaker telemetry, Holier monitoring, and exercise testing. Patients were visited at 2 and 12 weeks after implantation thereafter followed by 6\u2010month intervals. Mean follow\u2010up period was 35 \u00b1 14 months. Three months after implantation, atrial sensing threshold was significantly higher in young patients: 1.18 \u00b1 0.58 mV (group A) versus 0.79 \u00b1 0.35 mV (group B), 0.68 \u00b1 0.33 mV (group C), and 0.60 \u00b1 0.25 mV (group D), P &lt; 0.001 for comparison of group A to all other groups. Atrial undersensing was observed less frequently in young patients: 6.9% (group A) versus 17.2% (group B), 24.1% (group C), and 27.6% (group D), P = 0.025 for intergroup comparisons. Sinus node dysfunction did not occur in group A. Atrial arrhythmias and loss of AV synchronized pacing mode occurred rarely in young patients: 0.6% (0.4%) per year in group A versus 1.3% (1.3%) in group B, 3.9% (3.4%) in group C, and 5.7% (7.4%) per year in group D, P &lt; 0.01 for intergroup comparisons. Our data show good atrial sensing performance, low incidence of sinus node dysfunction, and few atrial arrhythmias in young patients with VDD pacing for AV block. Thus, single lead VDD pacing can be recommended particularly for young patients with AV block.<\/jats:p>","DOI":"10.1111\/j.1540-8159.2000.tb00856.x","type":"journal-article","created":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T15:07:43Z","timestamp":1151507263000},"page":"863-869","source":"Crossref","is-referenced-by-count":17,"title":["Age Dependency of Sensing Performance and AV Synchrony in Single Lead VDD Pacing"],"prefix":"10.1111","volume":"23","author":[{"given":"UWE K.H.","family":"WIEGAND","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00dcRGEN","family":"POTRATZ","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FRANK","family":"BODE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"REGINA","family":"SCHNEIDER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"WERNER","family":"PETERS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HENDRIK","family":"BONNEMEIER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HUGO A.","family":"KATUS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,28]]},"reference":[{"key":"e_1_2_1_2_2","unstructured":"AntonioliGE GrassiG BaggioniGF.A single P\u2010sensing ventricle stimulating lead driving a VAT generator. In:MereC (ed.):Sixth World Symposium on Cardiac Pacing. Montreal Canada 1979 pp.34\u201339."},{"key":"e_1_2_1_3_2","first-page":"1175","article-title":"ACC\/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmic devices: A report of the ACC\/AHA Task Force on Practice Guidelines (Committee on Pacemaker Implantation)","volume":"31","author":"Gregoratos G","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.1999.tb00707.x"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(98)00024-1"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb03637.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1996.tb03332.x"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03761.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90769-W"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03764.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb02757.x"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1991.tb04092.x"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03762.x"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb02056.x"},{"key":"e_1_2_1_15_2","first-page":"459","article-title":"Atrial sensing by a new VDD pacemaker","volume":"84","author":"Voigtlander T","year":"1995","journal-title":"Z Kardiol"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003920050039"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-8703(05)80331-X"},{"key":"e_1_2_1_18_2","first-page":"159","article-title":"Sinus node dysfunction in children","volume":"33","author":"Lee WJ","year":"1992","journal-title":"Chung Hua Min Kuo Hsiao Erh Ko I Hsueh Hui Tsa Chih"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1253\/jcj.57.760"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(92)90615-3"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(91)90923-9"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.81.6.580"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.1995.00430050045005"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(19)35525-4"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb06115.x"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03739.x"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90615-T"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.74.1.76"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2000.tb00856.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2000.tb00856.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T18:10:48Z","timestamp":1698603048000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2000.tb00856.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,5]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2000,5]]}},"alternative-id":["10.1111\/j.1540-8159.2000.tb00856.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2000.tb00856.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,5]]}}}