{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T04:13:13Z","timestamp":1791778393764,"version":"4.3.4"},"reference-count":11,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T00:00:00Z","timestamp":1151452800000},"content-version":"vor","delay-in-days":2157,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2000,8]]},"abstract":"<jats:p>Pacemaker battery life is dependant on programmable parameters, principally pulse, amplitude and pulse duration. High factory default settings cause excessive current drain. The strength\u2010duration curve relates pacing threshold to pulse duration. The most energy efficient pacing occurs at chronaxie, a value of pulse duration derived from the curve. Strength\u2010duration curves were calculated for 325 acutely implanted pacing leads. Chronaxie and rheobase were compared for atrial and ventricular leads. Chronaxie was compared with actual programmed pulse duration. There were 101 atrial and 224 ventricular leads, all passive fixation. The curve fit was good, (mean error \u00b1 SD) 0.024 \u00b1 0.06 V for atrial curves and 0.008 \u00b1 0.034 V for ventricular curves. Mean (\u00b1 SD) atrial and ventricular chronaxies were 0.24 \u00b1 0.07 ms and 0.25 \u00b1 0.07 ms, respectively. A \u201cZ\u201d value of 1.4 indicated that chronaxies might have been from the same population. Mean (\u00b1 SD) atrial and ventricular rheobases were 0.51 \u00b1 0.2 V and 0.35 \u00b10.13 V, respectively. A \u201cZ\u201d value of 7.1 (P &lt; 0.001) suggested atrial and ventricular rheobases were from differing populations. AH patients had factory default pulse durations of 0.45 ms or 0.5 ms, exceeding acute chronaxie by a factor of two, thus, demonstrating suboptimal pacing. We conclude that understanding the strength\u2010duration curve is critical. Sensible programming of other pacing functions optimizes longevity. Battery drain is reduced by programming pulse duration to chronaxie with a doubling of voltage threshold at this point to achieve a safety margin. Further study of chronaxie drift with time is required.<\/jats:p>","DOI":"10.1111\/j.1540-8159.2000.tb00943.x","type":"journal-article","created":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T15:04:15Z","timestamp":1151507055000},"page":"1273-1277","source":"Crossref","is-referenced-by-count":42,"title":["<b>The Strength\u2010Duration Curve and Its Importance in Pacing Efficiency:<\/b> A Study of 325 Pacing Leads in 229 Patients"],"prefix":"10.1111","volume":"23","author":[{"given":"STEPHEN","family":"COATES","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"BARNABY","family":"THWAITES","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2006,6,28]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1063654"},{"key":"e_1_2_1_3_2","first-page":"280","article-title":"Definition experimentalie de \u013eexcitablilit\u00e9","volume":"77","author":"Lapique L.","year":"1909","journal-title":"Proc Soc: Biol"},{"key":"e_1_2_1_4_2","first-page":"446","article-title":"Sur la possibilit\u00e9 de render comparable entre eux les appareils cervant a \u013eexcitation \u00e9lectrique","volume":"35","author":"Weiss G","year":"1901","journal-title":"Arch Ital Biol"},{"key":"e_1_2_1_5_2","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1111\/j.1540-8159.1980.tb05236.x","article-title":"The chronaxie time and its practical importance","volume":"3","author":"Irnich W.","year":"1980","journal-title":"PACE"},{"key":"e_1_2_1_6_2","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/S0022-5223(19)41558-4","article-title":"Pulse duration variation and electrode size as a factor in pacemaker longevity","volume":"69","author":"Furman S","year":"1975","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_1_7_2","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/S0022-5223(19)40179-7","article-title":"The significance of electrode surface area and stimulating thresholds in permanent cardiac pacing","volume":"71","author":"Smyth NPD","year":"1976","journal-title":"J Thorac Cardiavasc Surg"},{"key":"e_1_2_1_8_2","first-page":"43","volume-title":"Modern Cardiac Pacing","author":"Barold S","year":"1985"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1981.tb03715.x"},{"issue":"2","key":"e_1_2_1_10_2","first-page":"245","article-title":"Reprogramming pacemakes enhances longevity and is cost\u2010effective","volume":"94","author":"Crossley GH","year":"1996","journal-title":"Circulation"},{"key":"e_1_2_1_11_2","first-page":"36","volume-title":"Modern Cardiac Pacing","author":"Barold S.","year":"1985"},{"key":"e_1_2_1_12_2","volume-title":"Cardiac Pacing","author":"Ellenbogen KA.","year":"1997"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2000.tb00943.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2000.tb00943.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T11:58:40Z","timestamp":1698580720000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2000.tb00943.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,8]]},"references-count":11,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2000,8]]}},"alternative-id":["10.1111\/j.1540-8159.2000.tb00943.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2000.tb00943.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,8]]}}}