{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:31:07Z","timestamp":1761561067549},"reference-count":21,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T00:00:00Z","timestamp":1151452800000},"content-version":"vor","delay-in-days":2126,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2000,9]]},"abstract":"<jats:p>The Morphology Discriminator (MD) feature is an elec\u2010trogram template matching algorithm that intends to improve tachycardia discrimination in implantable Cardioverter defibrillators (ICDs). The aim of this study was to evaluate the performance of this feature during spontaneously occurring ventricular and supraventricular tachyarrhythmias and exercise induced sinus tachycardia. Twenty\u2010three patients (20 men, 3 women; mean age 54.3 \u00b1 13.8 years) with pectorally implanted Ventritex Contour MD, Angstrom MD, and Profile MD ICDs were studied. The stability of the acquired morphology template and performance of the algorithm during spontaneous tachyarrhythmias were evaluated at follow\u2010up. A treadmill exercise test was performed in 16 patients along with continuous telemetric monitoring of matching scores. A satisfactory template could be acquired at baseline in 22 (96%) patients. Variations in electrogram morphology necessitated new template acquisition in seven (30%) patients at first follow\u2010up (6\u20138 weeks postimplant). During a mean follow\u2010up of 9.1 \u00b1 3.7 months, 56 ventricular tachycardia (VT) and 15 supraventricular tachycardia episodes (sinus tachycardia in two\u2010thirds) in 11 patients were all appropriately discriminated by the MD feature. Exercise testing showed appropriate, discrimination of sinus tachycardia in 15 (94%) of 16 patients. A common observation was post\u2010shock changes in electrogram morphology that resulted in transient mismatch with the template. In conclusion, the recently introduced MD feature in ICDs has a high sensitivity for detection of VT and high specificity for rejection of sinus tachycardia. Postshock changes in electrogram morphology have been observed that may cause inappropriate redetection. Marked variations of electrogram morphology over time may be a concern in some patients, especially during lead maturation.<\/jats:p>","DOI":"10.1111\/j.1540-8159.2000.tb00964.x","type":"journal-article","created":{"date-parts":[[2006,6,28]],"date-time":"2006-06-28T15:22:05Z","timestamp":1151508125000},"page":"1365-1374","source":"Crossref","is-referenced-by-count":19,"title":["Morphology Discriminator Feature for Enhanced Ventricular Tachycardia Discrimination in Implantable Cardioverter Defibrillators"],"prefix":"10.1111","volume":"23","author":[{"given":"FIRAT","family":"DURU","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"URS","family":"BAUERSFELD","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MARIETTE","family":"RAHN\u2010SCH\u00d6NBECK","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"RETO","family":"CANDINAS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,6,28]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1995.tb02570.x"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.87.6.1897"},{"key":"e_1_2_1_4_2","doi-asserted-by":"crossref","first-page":"2204","DOI":"10.1161\/01.CIR.91.8.2204","article-title":"Limitations and late complications of third\u2010generation automatic cardioverter\u2010defibrilla\u2010tors","volume":"91","author":"Nunain SO","year":"1995","journal-title":"Circulation"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960220220"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1995.tb02564.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(96)00501-2"},{"key":"e_1_2_1_8_2","unstructured":"Morphology as a diagnostic tool for arrhythmia classification.St. Jude Medical Cardiac Rhythm Management Division Technical Note No. P0503."},{"key":"e_1_2_1_9_2","first-page":"21","article-title":"A chronotropic assessment exercise protocol to assess the need and efficacy of rate responsive pacing","volume":"20","author":"Blackburn G","year":"1988","journal-title":"Med Sci Sports Exerc"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb05002.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.77.6.1363"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1992.tb03038.x"},{"key":"e_1_2_1_13_2","first-page":"37","article-title":"Template matching techniques for electrophysiologic signals: A practical, real\u2010time system for detection of ventricular tachycardia","volume":"28","author":"Greenhut SE.","year":"1992","journal-title":"Biomed Sci Instrum"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1992.tb03142.x"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb05430.x"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1999.tb00328.x"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(96)80593-6"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00250.x"},{"key":"e_1_2_1_19_2","first-page":"1039","article-title":"The potunlial For inappropriate ventricular tachycardia confirmation using the Intracardiac Electrogram (EGM) Width Criterion","volume":"22","author":"Duru F","year":"1999","journal-title":"PAGE"},{"key":"e_1_2_1_20_2","first-page":"124","article-title":"The reliability of the Electrogram Width Criterion in implanted cardioverter defibrillators depends on changes of the body position","volume":"22","author":"Lenenherger H.","year":"1999","journal-title":"PACE"},{"key":"e_1_2_1_21_2","first-page":"245","article-title":"Improved supraventricular and ventricular tachycardia discrimination using electrogram morphology in an implantable cardioverter defibrillator","volume":"28","author":"Shieh M.","year":"1998","journal-title":"C Ital Cardiol"},{"key":"e_1_2_1_22_2","first-page":"A123","article-title":"for the St. Jude Medical\u2014Veutritex study group. Effectivity of a new algorithm for reduction of inadequate ICD shocks","volume":"22","author":"Achtelik M","year":"1999","journal-title":"PACE"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2000.tb00964.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2000.tb00964.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T17:14:25Z","timestamp":1698599665000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2000.tb00964.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,9]]},"references-count":21,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2000,9]]}},"alternative-id":["10.1111\/j.1540-8159.2000.tb00964.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2000.tb00964.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,9]]}}}