{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:03:16Z","timestamp":1762506196244},"reference-count":10,"publisher":"Wiley","issue":"11P2","license":[{"start":{"date-parts":[[2013,10,17]],"date-time":"2013-10-17T00:00:00Z","timestamp":1381968000000},"content-version":"vor","delay-in-days":4733,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2000,11]]},"abstract":"<jats:p>Two types of new\u2010generation transvenous implantable cardioverter defibrillator (ICD) systems, incorporating a two\u2010coil (62 patients, group 1) versus single\u2010coil (32 patients, group 2) lead system were compared among 94 consecutive patients. The two groups were comparable in age (58 \u00b1 13 vs 59 \u00b1 14 years), presenting arrhythmia (ventricular tachycardia versus ventricular fibrillation 77%\/21% vs 84%\/13%), cycle length of induced VT (294 \u00b1 4 vs 289 \u00b1 44 ms), number of unsuccessful antiarrhythmic drugs (1.7 \u00b1 0.8 vs 1.7 \u00b1 0.7), and left ventricular ejection fraction (35 \u00b1 12% vs 34 \u00b1 9%). Both systems were successfully implanted strictly transvenously in all patients. Biphasic shocks were used in all patients. Active shell devices were used in 79% and 84% patients of groups I and II, respectively (P = NS). Intraoperative testing revealed comparable defibrillation threshold (DFT) values (10.2 \u00b1 3.7 J in group 1 versus 9.3 \u00b1 3.6 J in group 2 system), and pacing threshold (0.7 \u00b1 0.3 vs 0.7 \u00b1 0.3 V), but R wave amplitude and lead impedance were lower in group 1 (13 \u00b1 5 vs 16 \u00b1 5 mV, P = 0.003; and 579 \u00b1 115 vs 657 \u00b1111 ohms, P = 0.002, respectively). Lead insulation break requiring reoperation occurred in one patient with an Endotak lead, and two patients with Transvene leads had initially high DFT with a single one\u2010lead\/active can system, which was converted to a two\u2010 or three\u2010endocardial\u2010lead\/'inactive can configuration. We conclude that both single\u2010coil and two\u2010coil transvenous ICD systems were associated with high rates of successful strictly transvenous ICD implantation and a low incidence of lead\u2010related complications. Significant differences were noted in the sensed R wave and lead impedance, probably reflecting the active fixation characteristics of the Transvene lead. However, in order to obviate the sporadic need for implantation of additional endocardial leads, as was the case in two patients in this series, a double\u2010coil lead may be preferable.<\/jats:p>","DOI":"10.1111\/j.1540-8159.2000.tb07072.x","type":"journal-article","created":{"date-parts":[[2013,10,17]],"date-time":"2013-10-17T13:42:20Z","timestamp":1382017340000},"page":"1999-2002","source":"Crossref","is-referenced-by-count":11,"title":["Two\u2010Coil Versus Single\u2010Coil Transvenous Cardioverter Defibrillator Systems: Comparative Data"],"prefix":"10.1111","volume":"23","author":[{"given":"ANTONIS S.","family":"MANOLIS","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JOHN","family":"CHILADAKIS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"THEMOS N.","family":"MAOUNIS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"VASSILIS","family":"VASSILIKOS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"DENNIS V.","family":"COKKINOS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2013,10,17]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.84.2.665"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.88.2.543"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.89.3.1090"},{"key":"e_1_2_1_5_2","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1001\/archinte.1994.00420060037004","article-title":"Transvenous endocardial cardioverter defibrillator systems: is the future here?","volume":"154","author":"Manolis AS","year":"1994","journal-title":"Arch Intern Med"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(94)90280-1"},{"key":"e_1_2_1_7_2","volume-title":"Automatic Implantable Cardioverter Defibrillators: A Comprehensive Text","author":"Estes NAM","year":"1994"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960200207"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(98)00103-X"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1999.tb00475.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2000.tb00654.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2000.tb07072.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2000.tb07072.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T15:18:13Z","timestamp":1698592693000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2000.tb07072.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,11]]},"references-count":10,"journal-issue":{"issue":"11P2","published-print":{"date-parts":[[2000,11]]}},"alternative-id":["10.1111\/j.1540-8159.2000.tb07072.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2000.tb07072.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,11]]}}}