{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T05:11:15Z","timestamp":1694495475533},"reference-count":22,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2004,2,6]],"date-time":"2004-02-06T00:00:00Z","timestamp":1076025600000},"content-version":"vor","delay-in-days":5,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2004,2]]},"abstract":"<jats:p> <jats:italic>The potential value of ventricular evoked response (VER) evaluation by implantable pacemakers as clinical marker for disease induced hemodynamic changes in the heart, has so far not been explicitly evaluated. We conducted a study to evaluate the reproducibility of the R spike and T wave measurements (R<jats:sub>(VER)<\/jats:sub> and T<jats:sub>(VER)<\/jats:sub>) under controlled clinical conditions and examine the correlation between VER parameters and standard echocardiographic measurements in the left ventricle. Additionally, the utility of the VER as a marker for NYHA classification and the presence of cardiomyopathy was investigated. The Physios CTM 01 pacemaker capable of recording authentic VER signal morphology, was used with low polarization fractal coated pacing leads to obtain high\u2010fidelity VER recordings in 26 patients with conventional pacing indications (mean age: 69.1 \u00b1 11.8 years; 20 men). Three patients suffered from dilative cardiomyopathy (DCM), 14 from hyperthropic nonobstructive cardiomyopathy (HNCM), and nine had no myopathy but suffered from coronary artery disease (CAD). Five patients were in NYHA Class IV, 19 in Class III, and two in Class II. Mean R<jats:sub>(VER)<\/jats:sub> and T<jats:sub>(VER)<\/jats:sub> amplitudes were calculated from one\u2010minute VER recordings. Standard echocardiography parameters were determined during this recording. Two follow\u2010ups at a mean distance of 11.3 \u00b1 5.7 month were performed. The reproducibility of R<jats:sub>(VER)<\/jats:sub> or T<jats:sub>(VER)<\/jats:sub> (correlation factors: 0.992 and 0.981, respectively) was superior to the reproducibility of any echocardiographic parameter (correlation factors 0.404\u20130.943). There was no strong correlation between VER and any echo parameter. Both R<jats:sub>(VER)<\/jats:sub> and T<jats:sub>(VER)<\/jats:sub> were significantly reduced in NYHA Class IV patients (P &lt; 0.05), and nearly significantly reduced in DCM versus other patients (P = 0.05\u20130.09). HNCM made no difference to CAD. The investigation shows that analysis of VER parameters bears a promising potential for dynamic monitoring of diseases affecting the hemodynamics, and of therapeutic effects, by means of regular, nonburdening pacemaker follow\u2010up examinations. (PACE 2004; 27:166\u2013174)<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2004.00406.x","type":"journal-article","created":{"date-parts":[[2004,2,6]],"date-time":"2004-02-06T22:05:53Z","timestamp":1076105153000},"page":"166-174","source":"Crossref","is-referenced-by-count":2,"title":["Ventricular Evoked Response as Clinical Marker for Hemodynamic Changes in Dilative Cardiomyopathy"],"prefix":"10.1111","volume":"27","author":[{"given":"ERICH","family":"EBNER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HANNES","family":"KR\u00c4TSCHMER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"DEJAN","family":"DANILOVIC","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MARTIN","family":"HRIBERNIGG","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HELMUT","family":"HUTTEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,2,6]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.1994.tb01192.x"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-662-00818-8_63"},{"key":"e_1_2_6_4_2","first-page":"60","article-title":"Prediction of the onset of atrial fibrillation after cardiac surgery using the monophasic action potential","volume":"1","author":"Pichlmaier AM","year":"1996","journal-title":"Prog Biomed Res"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb01179.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2000.tb00650.x"},{"key":"e_1_2_6_7_2","first-page":"259","article-title":"Fractal coated leads: Advanced surface technology for genuine sensing and pacing","volume":"5","author":"Schaldach M","year":"2000","journal-title":"Prog Biomed Res"},{"key":"e_1_2_6_8_2","first-page":"726","article-title":"The ventricular evoked response as a sensor for rate adaptive pacing\u2014an experimental study","volume":"23","author":"Brummer T","year":"2000","journal-title":"PACE"},{"key":"e_1_2_6_9_2","first-page":"50","article-title":"High resolution monitoring of intracardiac signals with a DDD pacemaker","volume":"1","author":"Dauer W","year":"1996","journal-title":"Prog Biomed Res"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-94-011-0872-0_18"},{"key":"e_1_2_6_11_2","first-page":"44","article-title":"The fractal coated lead as implantable sensor for monophasic action potentials","volume":"1","author":"Fr\u00f6hlich R","year":"1996","journal-title":"Prog Biomed Res"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-1-4160-2536-8.50022-4"},{"key":"e_1_2_6_13_2","first-page":"79","article-title":"Long term monitoring of the intrinsic ventricular monophasic action potential with an implantable DDD pacemaker","volume":"2","author":"Lawo T","year":"1998","journal-title":"Prog Biomed Res"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb01178.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00244.x"},{"key":"e_1_2_6_16_2","first-page":"291","article-title":"Output adjustment with the DDD pacemaker with automatic capture\u2010control algorithm","volume":"3","author":"Guilleman D","year":"1999","journal-title":"Prog Biomed Res"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1983.tb04478.x"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb02044.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1999.tb00351.x"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-2498(00)00126-1"},{"key":"e_1_2_6_21_2","first-page":"400","article-title":"Automatic processing of intramyocardial electrograms","volume":"37","author":"Schreier G","year":"1999","journal-title":"Med Biol Eng Comp"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(85)90657-5"},{"key":"e_1_2_6_23_2","volume-title":"Kardiopulmonale Funktionsdiagnostik [Book in German]","author":"L\u00f6llgen H","year":"1990"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2004.00406.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2004.00406.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,11]],"date-time":"2023-09-11T10:41:13Z","timestamp":1694428873000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2004.00406.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,2]]},"references-count":22,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2004,2]]}},"alternative-id":["10.1111\/j.1540-8159.2004.00406.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2004.00406.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,2]]}}}