{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T06:04:33Z","timestamp":1760249073908},"reference-count":20,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2004,3,4]],"date-time":"2004-03-04T00:00:00Z","timestamp":1078358400000},"content-version":"vor","delay-in-days":3,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2004,3]]},"abstract":"<jats:p> <jats:italic>Atrioventricular delay (AVD) is critical in patients with DDD pacemakers (PM). Echo\/Doppler evaluation of AVD providing the longest left ventricular filling time (FT) or the highest cardiac output (CO) is used for AVD optimization. Recently myocardial performance index (MPI) has been shown to improve by optimizing AVD. The aim was to compare the CO, FT, MPI derived optimal AVD, and to analyze systolic and diastolic performance at every optimal AVD. Twenty\u2010five patients, 16 men 68 \u00b1 11 years, ejection fraction \u2265 50%, with a DDD PM for third\u2010degree AV block, without other major cardiomyopathies, underwent echo\/Doppler AVD optimization. CO, FT, and MPI derived optimal AVDs were identified as the AVDs providing the highest CO, the longest FT, and the minimum MPI, respectively. Isovolumic contraction and relaxation time (ICT, IRT), ejection time (ET), ICT\/ET, and IRT\/ET ratios were also evaluated at every optimal AVD. CO, FT, and MPI derived optimal AVDs were significantly different (148 \u00b1 36 ms, 116 \u00b1 34 ms, and 127 \u00b1 33 ms, respectively). ICT\/ET was similar at CO, FT, and MPI derived optimal AVD (0.22 \u00b1 0.10, 0.23 \u00b1 0.11, and 0.21 \u00b1 0.10, respectively). IRT\/ET ratio was similar at FT and MPI derived optimal AVDs (0.34 \u00b1 0.15 and 0.33 \u00b1 0.15, respectively) and significantly shorter (P &lt; 0.02) than at CO derived optimal AVD (0.40 \u00b1 0.15). Different methods indicate different optimal AVDs. However analysis of systolic and diastolic performance shows that different AVDs result in similar systolic or diastolic performance. At MPI optimized AVD, a high CO combined with the most advantageous conditions of both isovolumic contraction and relaxation phases is achieved. (PACE 2004; 27:333\u2013338)<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2004.00437.x","type":"journal-article","created":{"date-parts":[[2004,3,4]],"date-time":"2004-03-04T09:39:52Z","timestamp":1078393192000},"page":"333-338","source":"Crossref","is-referenced-by-count":13,"title":["A Perspective on Atrioventricular Delay Optimization in Patients with a Dual Chamber Pacemaker"],"prefix":"10.1111","volume":"27","author":[{"given":"MARIA","family":"CRISTINA PORCIANI","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"GIORGIO","family":"CORBUCCI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FABIO","family":"FANTINI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"NICOLA","family":"MUSILLI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALESSANDRA","family":"SABINI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ANTIONIO","family":"MICHELUCCI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ANDREA","family":"COLELLA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"PAOLO","family":"PIERAGNOLI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"GABRIELE","family":"DEMARCHI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LUIGI","family":"PADELETTI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,3,4]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.24.3.633"},{"key":"e_1_2_8_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb05487.x"},{"key":"e_1_2_8_4_2","doi-asserted-by":"publisher","DOI":"10.1053\/eupc.1998.0032"},{"key":"e_1_2_8_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2000.01618.x"},{"key":"e_1_2_8_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1986.tb05414.x"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2001.01660.x"},{"key":"e_1_2_8_8_2","first-page":"135","article-title":"New non\u2010invasive index for combined systolic and diastolic ventricular function","volume":"26","author":"Tei C","year":"1995","journal-title":"J Cardiol"},{"key":"e_1_2_8_9_2","first-page":"357","article-title":"New index of combined systolic and diastolic myocardial performance: A simple and reproducible measure of cardiac function\u2010 A study in normals and dilated cardiomyopathy","volume":"26","author":"Tei C","year":"1995","journal-title":"J Cardiol"},{"key":"e_1_2_8_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(96)00202-1"},{"key":"e_1_2_8_11_2","first-page":"611","article-title":"Prognostic value of a Doppler echocardiographic assessment of the effect of varying atrioventricular delay and pacemaker mode of left ventricular filling","volume":"115","author":"Dujardin KS","year":"1988","journal-title":"Am J Cardiol"},{"key":"e_1_2_8_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(88)90812-5"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03786.x"},{"key":"e_1_2_8_14_2","first-page":"855","article-title":"New method for determining the optimal AVD in paced DDD mode for complete atrioventricular block","volume":"18","author":"Ritter P","year":"1995","journal-title":"PACE"},{"key":"e_1_2_8_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(94)00419-Q"},{"key":"e_1_2_8_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(97)00348-2"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)01727-8"},{"key":"e_1_2_8_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1996.tb04184.x"},{"key":"e_1_2_8_19_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2001.01534.x"},{"key":"e_1_2_8_20_2","doi-asserted-by":"publisher","DOI":"10.1152\/ajplegacy.1921.56.3.439"},{"key":"e_1_2_8_21_2","first-page":"233","volume-title":"Cardiac Mechanics: Physiological, Clinical, and Mathematical Considerations","author":"Harris WS","year":"1974"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2004.00437.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2004.00437.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/j.1540-8159.2004.00437.x","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2004.00437.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,11]],"date-time":"2023-09-11T09:42:09Z","timestamp":1694425329000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2004.00437.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,3]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2004,3]]}},"alternative-id":["10.1111\/j.1540-8159.2004.00437.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2004.00437.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,3]]}}}