{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T18:17:48Z","timestamp":1793125068541,"version":"4.5.0"},"reference-count":3,"publisher":"Wiley","issue":"s1","license":[{"start":{"date-parts":[[2007,1,18]],"date-time":"2007-01-18T00:00:00Z","timestamp":1169078400000},"content-version":"vor","delay-in-days":17,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2007,1]]},"abstract":"<jats:p> <jats:italic>Determination of the optimal interventricular (VV) delay in cardiac resynchronization therapy currently relies on costly, time\u2010consuming echocardiographic (ECHO) methods. This study evaluated the performance of a new intracardiac electrogram (IEGM)\u2010based VV method compared to the aortic velocity time integral (AVTI) method of VV delay optimization. The study included two patient groups. Eleven patients enrolled by a single center in the Rhythm II ICD trial underwent prospective comparisons of the AVTI at the VV interval determined by the IEGM VV method versus the maximum AVTI at the echocardiographically determined optimal VV delay. In 61 patients enrolled in the RHYTHM VV trial, the same testing methods were compared retrospectively. In the prospective study, the maximum AVTI by the ECHO\u2010based method (24.3 \u00b1 7.9 cm), was closely correlated with maximum AVTI by the IEGM\u2010based method (23.9 \u00b1 7.9 cm; concordance correlation coefficient = 0.99; 95% confidence, lower limit of 98%. Likewise, in the retrospective analysis, the ECHO\u2010determined maximum AVTI (22.1 \u00b1 8.2 cm) was similar to that determined by the IEGM\u2010based method (20.9 \u00b1 8.3 cm; concordance correlation coefficient = 0.98; 95% confidence, lower limit of 97%).<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2007.00597.x","type":"journal-article","created":{"date-parts":[[2007,1,18]],"date-time":"2007-01-18T22:34:01Z","timestamp":1169159641000},"source":"Crossref","is-referenced-by-count":7,"title":["Estimation of the Optimal VV Delay by an IEGM\u2010Based Method in Cardiac Resynchronization Therapy"],"prefix":"10.1111","volume":"30","author":[{"given":"XIAOYI","family":"MIN","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MATHIAS","family":"MEINE","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"II","given":"JAMES H.","family":"BAKER","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"LUIS A.","family":"PIRES","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KYONG T.","family":"TURK","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"EVELYN M.","family":"HORN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ROBERT C.","family":"KOWAL","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MICHAEL","family":"PARIS","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"EULJOON","family":"PARK","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ERIC S.","family":"FAIN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,1,18]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000034512.90874.8E"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2005.07.016"},{"key":"e_1_2_6_4_2","first-page":"8","article-title":"Hype, hope, or help: Optimization of AV\/PV delays and V\u2010V timing in the CRT\u2010D population\u2014experience from the ACT registry","volume":"8","author":"Deering T","year":"2006","journal-title":"Europace"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2007.00597.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2007.00597.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T07:00:15Z","timestamp":1695798015000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2007.00597.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,1]]},"references-count":3,"journal-issue":{"issue":"s1","published-print":{"date-parts":[[2007,1]]}},"alternative-id":["10.1111\/j.1540-8159.2007.00597.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2007.00597.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,1]]}}}