{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:33:03Z","timestamp":1761561183566},"reference-count":15,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2008,7,15]],"date-time":"2008-07-15T00:00:00Z","timestamp":1216080000000},"content-version":"vor","delay-in-days":318,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2007,9]]},"abstract":"<jats:p> <jats:italic>\n            <jats:bold>Background:<\/jats:bold> Most defibrillator (ICD) trials have excluded patients on hemodialysis (HD). It is therefore not known whether the ICD, when indicated, confers the same mortality benefit to HD and non\u2010HD patients.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Method:<\/jats:bold> HD patients implanted with an ICD from July 2001 to June 2004 were matched by age, gender, left ventricular ejection fraction (LVEF), and class of heart failure to non\u2010HD ICD recipients.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Results:<\/jats:bold> Forty\u2010six (16 on HD) patients (age = 65 \u00b1 15 yrs, LVEF = 30 \u00b1 14%, 44% in class III\u2010IV HF) were followed for a mean of 30 \u00b1 16 months (range, 4\u201361 months) after ICD implantation. During this period, 12\/16 HD versus 9\/30 non\u2010HD patients died (P = 0.006). The two\u2010year mortality rates were 54% and 29% in the HD and non\u2010HD groups, respectively (P = 0.01). After correcting for age, gender, race, LVEF, class of HF, and ICD indication (primary vs. secondary prevention) in a Cox regression model, HD remained a significant predictor of the time to death (HR = 2.9, adjusted P = 0.023).<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Conclusion:<\/jats:bold> Despite having an ICD, HD patients have approximately a three\u2010fold increase in total mortality and may therefore not extract the same survival benefits from the ICD as their non\u2010HD counterparts. If duplicated in larger randomized trials, these results may demonstrate the futility of implanting defibrillators in HD patients.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2007.00818.x","type":"journal-article","created":{"date-parts":[[2007,8,21]],"date-time":"2007-08-21T04:47:25Z","timestamp":1187671645000},"page":"1091-1095","source":"Crossref","is-referenced-by-count":28,"title":["Effect of End\u2010Stage Renal Failure and Hemodialysis on Mortality Rates in Implantable Cardioverter\u2010Defibrillator Recipients"],"prefix":"10.1111","volume":"30","author":[{"given":"HAITHAM","family":"HREYBE","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"EATHAR","family":"RAZAK","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SAMIR","family":"SABA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,7,15]]},"reference":[{"key":"e_1_2_5_2_2","volume-title":"YSRDS Annual Data Report","author":"US Renal Data System"},{"key":"e_1_2_5_3_2","unstructured":"http:\/\/www.usrds.org"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2005.06.042"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00526.x"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0085-2538(15)50904-6"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199711273372202"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.101.11.1297"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.7.748"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM200006293422602"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199612263352601"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa013474"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa043399"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1023\/B:JICE.0000048570.43706.34"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1523-1755.2004.00657.x"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1159\/000063556"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2007.00818.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2007.00818.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T04:54:16Z","timestamp":1697086456000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2007.00818.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,9]]},"references-count":15,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2007,9]]}},"alternative-id":["10.1111\/j.1540-8159.2007.00818.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2007.00818.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,9]]}}}