{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T01:30:29Z","timestamp":1789435829465,"version":"build-2803163510"},"reference-count":16,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2008,4,24]],"date-time":"2008-04-24T00:00:00Z","timestamp":1208995200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2008,5]]},"abstract":"<jats:p> <jats:italic>\n            <jats:bold>Background:<\/jats:bold> Optimization of cardiac resynchronization therapy (CRT) with respect to the interventricular (V\u2010V) interval is mainly limited to pacing at a resting heart rate. We studied the effect of higher stimulation rates with univentricular and biventricular (BiV) pacing modes including the effect of the V\u2010V interval optimization.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Methods:<\/jats:bold> In 36 patients with heart failure and chronic atrial fibrillation (AF), the effects of right ventricular (RV), left ventricular (LV), simultaneous BiV, and optimized sequential BiV (BiVopt) pacing were measured. The effect of the pacing mode and the optimal V\u2010V interval was determined at stimulation rates of 70, 90, and 110 ppm using invasive measurement of the maximum rate of left ventricular pressure rise (LV dP\/dt<jats:sub>max<\/jats:sub>)<\/jats:italic>.<\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Results:<\/jats:bold> The average LV dP\/dt <jats:sub>max<\/jats:sub> for all pacing modalities at stimulation rates of 70, 90, and 110 ppm was 781 \u00b1 176, 833 \u00b1 197, and 884 \u00b1 223 mmHg\/s for RV pacing; 893 \u00b1 178, 942 \u00b1 186, and 981 \u00b1 194 mmHg\/s for LV pacing; 904 \u00b1 179, 973 \u00b1 187, and 1052 \u00b1 206 mmHg\/s for simultaneous BiV pacing; and 941 \u00b1 186, 1010 \u00b1 198, and 1081 \u00b1 206 mmHg\/s for BiVopt pacing, respectively. In BiVopt pacing, the corresponding optimal V\u2010V interval decreased from 34 \u00b1 29, 28 \u00b1 28, and<\/jats:italic>\n          <jats:italic>21 \u00b1 27<\/jats:italic>\n          <jats:italic>ms at stimulation rates of 70, 90, and 110 ppm, respectively<\/jats:italic>\n          <jats:italic>. In two individuals, LV dP\/dt<jats:sub>max<\/jats:sub> decreased when the pacing rate was increased from 90 to 110 ppm.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Conclusion:<\/jats:bold> In patients with AF and heart failure, LV dP\/dt<jats:sub>max<\/jats:sub> increases for all pacing modalities at increasing stimulation rates in most, but not all, patients. The rise in LV dP\/dt<jats:sub>max<\/jats:sub> with increasing stimulation rates is higher in biventricular (BiV and BiVopt) than in univentricular (LV and RV) pacing. The optimal V\u2010V interval at sequential biventricular pacing decreases with increasing stimulation rates.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2008.01042.x","type":"journal-article","created":{"date-parts":[[2008,4,24]],"date-time":"2008-04-24T19:58:32Z","timestamp":1209067112000},"page":"569-574","source":"Crossref","is-referenced-by-count":16,"title":["Stimulation Rate and the Optimal Interventricular Interval during Cardiac Resynchronization Therapy in Patients with Chronic Atrial Fibrillation"],"prefix":"10.1111","volume":"31","author":[{"given":"BERRY M.","family":"VAN GELDER","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ALBERT","family":"MEIJER","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FRANK A.","family":"BRACKE","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,4,24]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.99.23.2993"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa050496"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1388-9842(02)00204-0"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2004.02.061"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(03)00641-7"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000148177.82319.C7"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.105.579987"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.105.604603"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2005.08.021"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2005.02.098"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2006.07.064"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(01)02200-7"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)02937-6"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2003.10.038"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2003.09.027"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2006.03.056"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2008.01042.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2008.01042.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T14:15:00Z","timestamp":1697120100000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2008.01042.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,4,24]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2008,5]]}},"alternative-id":["10.1111\/j.1540-8159.2008.01042.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2008.01042.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,4,24]]}}}