{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T07:30:48Z","timestamp":1787729448153,"version":"build-2784847793"},"reference-count":24,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2008,8,28]],"date-time":"2008-08-28T00:00:00Z","timestamp":1219881600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2008,9]]},"abstract":"<jats:p> <jats:bold>\n            <jats:italic>Background:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>The aim of the study was to analyze endovenous pacing lead survival in pediatric population implanted by cephalic cut down, or by axillary vein puncture.<\/jats:italic> <\/jats:p><jats:p> <jats:bold>\n            <jats:italic>Methods:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>All implantations were performed in total endotracheal anesthesia, by the same surgeon. Implantations of ventricular leads were performed by cephalic vein cut down or by external jugular vein preparation. In dual\u2010chamber pacing, atrial leads were implanted via cephalic vein (along with ventricular lead), by axillary vein puncture or via external jugular vein. All implanted leads were secured by resorbable suture.<\/jats:italic> <\/jats:p><jats:p> <jats:bold>\n            <jats:italic>Results:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>Over the 20\u2010year follow\u2010up period, 105 children of 5.7 years average age (range 1 day\u201315 years) were implanted with a permanent endovenous pacing system for congenital or postsurgical complete atrioventricular block or sinus node disease. Within the group, 27 patients (25.7%) weighed less than 10 kg on implantation. A total of 121 endovenous leads were implanted. All ventricular leads were with a passive fixation mechanism, and most of them unipolar (87.6%) and steroid eluting (94.2%). Leads implanted in atrial position were 82% bipolar, predominantly with active fixation (94%), and all steroid eluting. The most frequently used mode of stimulation was VVIR (66.6%). No acute or chronic lead displacement, exit block, sensing problem, lead conductor fracture, insulation defect or infections were observed during the total follow\u2010up of 709 pacing years (average 6.9, range 0\u201320 years).<\/jats:italic> <\/jats:p><jats:p> <jats:bold>\n            <jats:italic>Conclusion:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>Implantation of the endovenous leads by preparation of the cephalic or puncture of the axillary vein, with lead fixation by resorbable suture represents a method of choice.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2008.01148.x","type":"journal-article","created":{"date-parts":[[2008,8,28]],"date-time":"2008-08-28T15:05:32Z","timestamp":1219935932000},"page":"1100-1107","source":"Crossref","is-referenced-by-count":15,"title":["Permanent Endovenous Pediatric Pacing: Absence of Lead Failure\u201420 Years Follow\u2010Up Study"],"prefix":"10.1111","volume":"31","author":[{"given":"PETAR L.","family":"STOJANOV","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DRAGUTIN V.","family":"SAVIC","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MIRJANA B.","family":"ZIVKOVIC","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ZARKO R.","family":"CALOVIC","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,8,28]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0167-5273(91)90348-S"},{"key":"e_1_2_6_3_2","first-page":"S9","article-title":"Danish pacemaker and ICD register","volume":"23","author":"Mognes Moller, Per Arnsbo","year":"2000","journal-title":"Pacing Clin Electrophysiol"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb04013.x"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2004.00663.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.09254.x"},{"key":"e_1_2_6_7_2","first-page":"9","volume-title":"Pediatric Cardiac Pacing","author":"Gillette PC","year":"1995"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0967-2109(00)00099-5"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb01062.x"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1020206"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1990.tb02086.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)90229-R"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1986.tb06600.x"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1999.tb00531.x"},{"key":"e_1_2_6_15_2","unstructured":"Medtronic News Winter 1986 87 p.27."},{"key":"e_1_2_6_16_2","first-page":"748","article-title":"A possible complication of subclavian stick conductor fracture","volume":"10","author":"Stokes K","year":"1987","journal-title":"Pacing Clin Electrophysiol"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01606.x"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01607.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01729.x"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/1058-9813(95)00103-A"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2004.02.020"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(00)00364-X"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2004.00663.x"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2004.00662.x"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1536\/ihj.34.193"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2008.01148.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2008.01148.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T14:19:26Z","timestamp":1697293166000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2008.01148.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,8,28]]},"references-count":24,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2008,9]]}},"alternative-id":["10.1111\/j.1540-8159.2008.01148.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2008.01148.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,8,28]]}}}