{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:35:02Z","timestamp":1761561302322},"reference-count":42,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,12,23]],"date-time":"2008-12-23T00:00:00Z","timestamp":1229990400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2009,1]]},"abstract":"<jats:p> <jats:italic>\n            <jats:bold>Background:<\/jats:bold> Atrial fibrillation (AF) is a major cause of morbidity and mortality, especially in patients with congestive heart failure.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Objectives:<\/jats:bold> The purposes of this international, prospective multicenter study were to evaluate the efficacy of atrial shock therapy in patients with a cardiac resynchronization therapy defibrillator (CRT\u2010D) and to evaluate the safety of the new CRT\u2010D. The effectiveness of a new wireless telemetry system was also evaluated.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Methods:<\/jats:bold> A total of 282 patients, without permanent AF, who had indications for a CRT\u2010D were included. Atrial shock therapy was tested on both spontaneous and induced AF episodes. The effectiveness of the Medtronic wireless telemetry system (Conexus; Medtronic Inc., Minneapolis, MN, USA) was also tested. Secondary endpoints included the heart failure Clinical Composite Response, system performance evaluation, and adverse event summary.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Results:<\/jats:bold> Atrial shock therapy was successful in 168 of 171 episodes (98.2%). Of these, 138 episodes were induced and 33 were spontaneous. Successful cardioversion occurred in 137 of the 138 induced\u2010AF episodes (86.1% with 12 joule (J), 13.1% with 24 J, and 0.7% with 35 J). During the first 3 months of implant, there were 43 system\u2010related complications in 37 subjects out of 278 subjects. There were 1,999 Conexus telemetry uses recorded during this study. This includes 282 uses during the implant procedure. There were no cases of complete loss of telemetry or any adverse events reported using this system.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Conclusion:<\/jats:bold> We achieved an atrial shock efficacy of 98.2% in patients who met standard CRT\u2010D indications. The wireless telemetry performed well with no reported unanticipated adverse device effects.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2009.02171.x","type":"journal-article","created":{"date-parts":[[2008,12,23]],"date-time":"2008-12-23T19:06:24Z","timestamp":1230059184000},"page":"13-23","source":"Crossref","is-referenced-by-count":10,"title":["Atrial Fibrillation Therapy in Patients with a CRT Defibrillator with Wireless Telemetry"],"prefix":"10.1111","volume":"32","author":[{"given":"GEORGE H.","family":"CROSSLEY","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"KAZUTAKA","family":"AONUMA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHARLES","family":"HAFFAJEE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MORIO","family":"SHODA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALBERT","family":"MEIJER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALEXANDER","family":"BAUER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"GIUSEPPE","family":"BORIANI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JESPER","family":"SVENDSEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SHELLEY","family":"THOMAS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHRISTOPHER","family":"WIGGENHORN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHRISTINA","family":"UNTERBERG\u2010BUCHWALD","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"for the Concerto\u2010AT Study Investigators","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,23]]},"reference":[{"key":"e_1_2_9_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.84.1.40"},{"key":"e_1_2_9_3_2","first-page":"128","article-title":"Atrial fibrillation as a contributing cause of death and Medicare hospitalization\u2013United States, 1999","volume":"52","author":"Centers for Disease Control and Prevention (CDC)","year":"2003","journal-title":"MMWR\u2014Morb Mortal Wkly Rep"},{"key":"e_1_2_9_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.179918"},{"key":"e_1_2_9_5_2","doi-asserted-by":"publisher","DOI":"10.1053\/euhj.1998.1280"},{"key":"e_1_2_9_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.82.4.486"},{"key":"e_1_2_9_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.00222.x"},{"key":"e_1_2_9_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.614560"},{"key":"e_1_2_9_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(98)00583-9"},{"key":"e_1_2_9_10_2","doi-asserted-by":"publisher","DOI":"10.1023\/A:1020097728178"},{"key":"e_1_2_9_11_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa013168"},{"key":"e_1_2_9_12_2","doi-asserted-by":"crossref","first-page":"2864","DOI":"10.1161\/01.CIR.0000146336.92331.D1","article-title":"on behalf of Multicenter ICD II Study Group. Effects of cardiac resynchronization on disease progression in patients with left ventricular systolic dysfunction, an indication for an implantable cardioverter\u2010defibrillator, and mildly symptomatic chronic heart failure","volume":"110","author":"Abraham WT","year":"2004","journal-title":"Circulation"},{"key":"e_1_2_9_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00440.x"},{"key":"e_1_2_9_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00482.x"},{"key":"e_1_2_9_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2006.03.056"},{"key":"e_1_2_9_16_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2003.03236.x"},{"key":"e_1_2_9_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2004.10.033"},{"key":"e_1_2_9_18_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2003.03123.x"},{"key":"e_1_2_9_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2007.00685.x"},{"key":"e_1_2_9_20_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.98.16.1594"},{"key":"e_1_2_9_21_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.103.16.2120"},{"key":"e_1_2_9_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(00)00579-9"},{"key":"e_1_2_9_23_2","doi-asserted-by":"publisher","DOI":"10.1054\/jcaf.2001.25652"},{"key":"e_1_2_9_24_2","doi-asserted-by":"publisher","DOI":"10.1161\/hc3401.095039"},{"key":"e_1_2_9_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(94)90915-6"},{"key":"e_1_2_9_26_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-126-8-199704150-00006"},{"key":"e_1_2_9_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(95)00286-5"},{"key":"e_1_2_9_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(98)00078-3"},{"key":"e_1_2_9_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)91392-H"},{"key":"e_1_2_9_30_2","doi-asserted-by":"publisher","DOI":"10.1002\/bem.2250050408"},{"key":"e_1_2_9_31_2","article-title":"1346: Sharing between the meteorological aids service and medical implant communication systems (MICS) operating in the mobile service in the frequency band 401\u2013406 MHz","author":"SA","year":"2007","journal-title":"International Telecommunications Union"},{"key":"e_1_2_9_32_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.285.18.2370"},{"key":"e_1_2_9_33_2","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.1995.00430050045005"},{"key":"e_1_2_9_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2006.07.018"},{"key":"e_1_2_9_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(87)90174-7"},{"key":"e_1_2_9_36_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.99.21.2765"},{"key":"e_1_2_9_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2005.04.053"},{"key":"e_1_2_9_38_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb04847.x"},{"key":"e_1_2_9_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ehj.2003.09.013"},{"key":"e_1_2_9_40_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2004.03406.x"},{"key":"e_1_2_9_41_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00416.x"},{"key":"e_1_2_9_42_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2004.00558.x"},{"key":"e_1_2_9_43_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa043399"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2009.02171.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2009.02171.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T17:18:27Z","timestamp":1697044707000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2009.02171.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,12,23]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,1]]}},"alternative-id":["10.1111\/j.1540-8159.2009.02171.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2009.02171.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"type":"print","value":"0147-8389"},{"type":"electronic","value":"1540-8159"}],"subject":[],"published":{"date-parts":[[2008,12,23]]}}}