{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T09:48:14Z","timestamp":1724924894351},"reference-count":13,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2009,3,23]],"date-time":"2009-03-23T00:00:00Z","timestamp":1237766400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2009,4]]},"abstract":"<jats:p> <jats:bold>\n            <jats:italic>Background:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>The diagnosis of presyncope, syncope, and palpitations is facilitated by successful documentation of the cardiac rhythm during symptoms. We prospectively assessed technological familiarity using a Technology Cognition Questionnaire to determine influence on proper and effective use of an external loop recorder (ELR).<\/jats:italic> <\/jats:p><jats:p> <jats:bold>\n            <jats:italic>Methods:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>Patients with palpitations, presyncope, or syncope were assessed for familiarity with technology and provided an ELR for a period of 6 weeks. Proper use of the device was demonstrated to the patient and test transmissions were sent by analog telephone line on a weekly basis. Patients were instructed to activate the device to record cardiac rhythm when symptoms recurred, and to send these recordings via telephone transmission.<\/jats:italic> <\/jats:p><jats:p> <jats:bold>\n            <jats:italic>Results:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>Ninety\u2010two patients were prospectively enrolled, with mean age 54.9 \u00b1 20.9 and 42 males (46%). Sixty\u2010five patients (71%) had recurrence of symptoms during the 6\u2010week monitoring period. Among these patients, 40 (62%) were successful in recording and transmitting data such that a diagnosis was made at a median of 8 days (IQR 12.5, range 0\u201330). Among patients with symptoms during the monitoring period, 36 (55%) had at least one failed recording or transmission. On multivariate analysis, failed symptom recording\/transmission was less likely among patients able to program a home video recorder (odds ratio [OR] 0.25 [0.07\u20130.93]), and more likely among patients who failed a test transmission (OR 3.45 [1.04\u201311.7]). No variables were independently associated with successful diagnosis.<\/jats:italic> <\/jats:p><jats:p> <jats:bold>\n            <jats:italic>Conclusions:<\/jats:italic>\n          <\/jats:bold>\n          <jats:italic>Familiarity with technology correlates with successful use of the ELR, but does not necessarily correlate with the ability to reach a diagnosis.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8159.2009.02306.x","type":"journal-article","created":{"date-parts":[[2009,3,23]],"date-time":"2009-03-23T17:39:22Z","timestamp":1237829962000},"page":"466-472","source":"Crossref","is-referenced-by-count":6,"title":["Does Familiarity with Technology Predict Successful Use of an External Loop Recorder? The Loop Recorder Technology Cognition Study (LOCO)"],"prefix":"10.1111","volume":"32","author":[{"given":"LORNE J.","family":"GULA","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"GEORGE J.","family":"KLEIN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"URSZULA","family":"ZURAWSKA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"DAVID","family":"MASSEL","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"RAYMOND","family":"YEE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALLAN C.","family":"SKANES","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ANDREW D.","family":"KRAHN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,3,23]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(84)90628-3"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-128-11-199806010-00002"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.104.1.46"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(90)90591-N"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2005.08.003"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2003.10.036"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9343(03)00233-X"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(96)00717-5"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007611-199001000-00013"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-124-1_Part_1-199601010-00003"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2004.12.015"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2007.00779.x"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1747-0803.2007.00162.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8159.2009.02306.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8159.2009.02306.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T17:48:14Z","timestamp":1697046494000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8159.2009.02306.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,3,23]]},"references-count":13,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2009,4]]}},"alternative-id":["10.1111\/j.1540-8159.2009.02306.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8159.2009.02306.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,3,23]]}}}