{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T10:06:20Z","timestamp":1760954780399},"reference-count":18,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2005,9,30]],"date-time":"2005-09-30T00:00:00Z","timestamp":1128038400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2005,10]]},"abstract":"<jats:p> <jats:italic>Background: The pressure half time (PHT) method is unreliable for measurement of mitral valve area (MVA) immediately after valvotomy. The proximal isovelocity surface area (PISA) method has been used to derive mitral valve area in patients with mitral stenosis. The aim of our study was to compare PISA method and PHT method in patients undergoing percutaneous balloon mitral valvotomy (BMV). Methods: The PISA was recorded from the apex and MVA was calculated using continuity equation by the formula 2\u03c0r<jats:sup>2<\/jats:sup> Vr\/Vm, where 2\u03c0r<jats:sup>2<\/jats:sup> is the hemispheric isovelocity area, Vr is the velocity at the radial distance \u201cr\u201d from the orifice, and Vm is the peak velocity. A plain angle correction factor (\u03b8)\/180 was used to correct the inlet angle subtended by leaflet tunnel as a result of leaflet doming. Results: MVA calculated using PISA method (r = 0.5217, P &lt; 0.0001, SE = 0.016) and PHT (r = 0.6652, P &lt; 0.0001, SE = 0.017) correlated well with 2D method in patients with mitral stenosis before BMV. After BMV, MVA by PISA method correlated well with 2D planimetry (r = 0.5803, P &lt; 0.0001, SE = 0.053) but PHT showed poor correlation (r = 0.1334, P = 0.199, SE = 0.036). The variability of measurement of MVA was most marked with PHT method in the post\u2010BMV period. Conclusion: The PISA method correlates well with 2D planimetry in patients with mitral stenosis before and after BMV and is superior to the PHT method in the post\u2010BMV period where the latter may be unreliable.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8175.2005.00082.x","type":"journal-article","created":{"date-parts":[[2005,9,30]],"date-time":"2005-09-30T08:54:26Z","timestamp":1128070466000},"page":"707-712","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of Proximal Isovelocity Surface Area Method and Pressure Half Time Method for Evaluation of Mitral Valve Area in Patients Undergoing Balloon Mitral Valvotomy"],"prefix":"10.1111","volume":"22","author":[{"given":"Thottuvelil Narayanan Sunil","family":"Roy","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mangalth Narayanan","family":"Krishnan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cherian","family":"Koshy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chakanalil Govindan","family":"Sajeev","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johnson","family":"Francis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chamapparayil Chandran","family":"Velayudhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Krishnannair","family":"Venugopal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,9,30]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.99.12.1580"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.78.4.980"},{"key":"e_1_2_6_4_2","first-page":"315","article-title":"What is the gold standard to measure mitral valve area in post mitral balloon valvotomy (editorial)","volume":"33","author":"Palacios IF","year":"1994","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.73.1.100"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.88.3.1157"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.55.1.120"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(79)90014-6"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.60.5.1096"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(95)00486-6"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(95)80023-A"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-7317(96)90065-6"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(89)90306-9"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.eurheartj.a015266"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1536\/ihj.38.811"},{"key":"e_1_2_6_17_2","first-page":"1201","article-title":"Validity of the proximal isovelocity surface area color Doppler method for calculating the valve area in patients with mitral stenosis. Comparison with 2D echocardiographic method","volume":"22","author":"Centamore G","year":"1992","journal-title":"G Ital Cardiol"},{"key":"e_1_2_6_18_2","first-page":"316","article-title":"The accuracy and applicability of different methods in the Doppler technique for the quantification of mitral stenosis","volume":"37","author":"Gonsales T","year":"1994","journal-title":"Rev Esp Cardiol"},{"key":"e_1_2_6_19_2","first-page":"133","article-title":"The \u201cProximal isovelocity surface area\u201d method in assessing mitral valve area in patients with mitral stenosis and associated regurgitation","volume":"27","author":"Centamore G","year":"1977","journal-title":"G Ital Cardiol"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8175.2005.00082.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8175.2005.00082.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T22:48:16Z","timestamp":1697064496000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8175.2005.00082.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,9,30]]},"references-count":18,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2005,10]]}},"alternative-id":["10.1111\/j.1540-8175.2005.00082.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8175.2005.00082.x","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"value":"0742-2822","type":"print"},{"value":"1540-8175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,9,30]]}}}