{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:15:48Z","timestamp":1761862548635},"reference-count":13,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2006,3,28]],"date-time":"2006-03-28T00:00:00Z","timestamp":1143504000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2006,4]]},"abstract":"<jats:p> <jats:italic>A 52\u2010year\u2010old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus\u2010like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel\u2010like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent \u201csignal fusion\u201d resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8175.2006.00214.x","type":"journal-article","created":{"date-parts":[[2006,3,28]],"date-time":"2006-03-28T12:17:06Z","timestamp":1143548226000},"page":"324-328","source":"Crossref","is-referenced-by-count":9,"title":["Intracardiac Echo Guided Valvuloplasty of a Stenotic Tricuspid Prosthetic Valve in a Patient with Idiopathic Hypereosinophilic Syndrome"],"prefix":"10.1111","volume":"23","author":[{"given":"Darryl J.","family":"Burstow","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Malcolm L.","family":"West","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Darren L.","family":"Walters","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,3,28]]},"reference":[{"key":"e_1_2_4_2_2","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/S0022-5223(19)37390-8","article-title":"Clinical application of transvenous commissurotomy by a new balloon catheter","volume":"87","author":"Inoue K","year":"1984","journal-title":"J Thor Cardiovasc Surg"},{"key":"e_1_2_4_3_2","doi-asserted-by":"crossref","first-page":"2759","DOI":"10.1182\/blood.V83.10.2759.2759","article-title":"The idiopathic hypereosinophilic syndrome review article","volume":"83","author":"Weller PF","year":"1994","journal-title":"Blood"},{"key":"e_1_2_4_4_2","doi-asserted-by":"publisher","DOI":"10.5694\/j.1326-5377.1985.tb123104.x"},{"key":"e_1_2_4_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(95)70253-9"},{"key":"e_1_2_4_6_2","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951102000136"},{"key":"e_1_2_4_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)02616-5"},{"key":"e_1_2_4_8_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8175.2002.00525.x"},{"key":"e_1_2_4_9_2","doi-asserted-by":"publisher","DOI":"10.1067\/mje.2000.105463"},{"key":"e_1_2_4_10_2","doi-asserted-by":"publisher","DOI":"10.1067\/mje.2002.121276"},{"key":"e_1_2_4_11_2","doi-asserted-by":"publisher","DOI":"10.1536\/ihj.35.809"},{"key":"e_1_2_4_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(94)90032-9"},{"key":"e_1_2_4_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(94)90695-5"},{"key":"e_1_2_4_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-5273(96)02898-7"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8175.2006.00214.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8175.2006.00214.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T22:29:39Z","timestamp":1696976979000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8175.2006.00214.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,3,28]]},"references-count":13,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2006,4]]}},"alternative-id":["10.1111\/j.1540-8175.2006.00214.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8175.2006.00214.x","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"value":"0742-2822","type":"print"},{"value":"1540-8175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,3,28]]}}}