{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T19:15:18Z","timestamp":1761765318586},"reference-count":22,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2010,7,9]],"date-time":"2010-07-09T00:00:00Z","timestamp":1278633600000},"content-version":"vor","delay-in-days":8,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2010,7]]},"abstract":"<jats:p>Aims: The aim of the study was to validate a novel formula for aortic valve area (AVA) based on the principle of continuity equation, that substitutes Doppler\u2010derived stroke volume (SV) by SV directly measured with real time simultaneous triplane three\u2010dimensional echocardiography (RT3P). RT3P has proved accuracy for left ventricular volume calculation. So far, however, neither this potential has been applied to hemodynamic assessment, nor RT3P has succeeded in the evaluation of aortic valve disease. Methods and results: AVA was measured in 21 patients with aortic stenosis using Gorlin's equation, Doppler continuity equation (two\u2010dimensional echocardiography), the novel RT3P method, and by substituting Doppler\u2010derived SV by SV measured with two\u2010dimensional stroke volume (2DSV). RT3P has the best linear association (R<jats:sup>2<\/jats:sup>= 0.61) and the best correlation with Gorlin of all noninvasive methods (even if not statistically significant). RT3P carries significantly lower mean differences with catheterization, as compared with 2D and 2DSV (Table 4). Standard deviations of mean differences between RT3P and catheterization and between the other echocardiographic methods are not statistically different, even if RT3P seems to be nearer to catheterization. Inter\u2010 and intraobserver variability were, respectively, 0.03 \u00b1 0.11 cm<jats:sup>2<\/jats:sup> and 0.02 \u00b1 0.03 cm<jats:sup>2<\/jats:sup>, better than 2D and 2DSV. Conclusions: RT3P has revealed to be more accurate than two\u2010dimensional method in AVA quantification, with a better intraobserver agreement. In addition, it allows simple and fast image acquisition. (Echocardiography 2010;27:644\u2010650)<\/jats:p>","DOI":"10.1111\/j.1540-8175.2009.01099.x","type":"journal-article","created":{"date-parts":[[2010,7,9]],"date-time":"2010-07-09T05:10:58Z","timestamp":1278652258000},"page":"644-650","source":"Crossref","is-referenced-by-count":6,"title":["Real Time Triplane Echocardiography in Aortic Valve Stenosis: Validation, Reliability, and Feasibility of a New Method for Valve Area Quantification"],"prefix":"10.1111","volume":"27","author":[{"given":"Gianluca","family":"Alunni","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauro","family":"Giorgi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chiara","family":"Sartori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo","family":"Garrone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Federico","family":"Conrotto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maurizio","family":"D\u2019Amico","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo","family":"Scacciatella","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Monica","family":"Andriani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario","family":"Levis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastiano","family":"Marra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,7,9]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90842-O"},{"key":"e_1_2_8_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8175.2006.00428.x"},{"key":"e_1_2_8_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2004.08.101"},{"key":"e_1_2_8_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8175.2008.00762.x"},{"key":"e_1_2_8_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(86)80460-0"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.73.3.452"},{"key":"e_1_2_8_8_2","doi-asserted-by":"publisher","DOI":"10.1159\/000174590"},{"key":"e_1_2_8_9_2","first-page":"985","article-title":"Aortic valve area discrepancy by Gorlin equation and Doppler echocardiography continuity equation: Relationship to flow in patients with valvular aortic stenosis","volume":"16","author":"Burwash IG","year":"2000","journal-title":"Can J Cardiol"},{"key":"e_1_2_8_10_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehm467"},{"key":"e_1_2_8_11_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehn022"},{"key":"e_1_2_8_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1076-7460.2004.02710.x"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(51)90002-6"},{"key":"e_1_2_8_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.73.5.964"},{"key":"e_1_2_8_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1445-5994.1988.tb02241.x"},{"key":"e_1_2_8_16_2","doi-asserted-by":"crossref","first-page":"e1\u2013e142","DOI":"10.1016\/j.jacc.2008.05.007","article-title":"2008 focused update incorporated into the ACC\/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines (Writing Committee to revise the 1998 guidelines for the management of patients with valvular heart disease). Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons","volume":"52","author":"Bonow RO","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(83)80200-9"},{"key":"e_1_2_8_18_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2004.03625.x"},{"key":"e_1_2_8_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_8_20_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehl023"},{"key":"e_1_2_8_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2006.06.021"},{"key":"e_1_2_8_22_2","doi-asserted-by":"publisher","DOI":"10.1081\/JCMR-200060644"},{"key":"e_1_2_8_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-006-0355-1"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8175.2009.01099.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8175.2009.01099.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T09:30:41Z","timestamp":1698744641000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8175.2009.01099.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2010,7]]}},"alternative-id":["10.1111\/j.1540-8175.2009.01099.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8175.2009.01099.x","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"value":"0742-2822","type":"print"},{"value":"1540-8175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7]]}}}