{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T18:33:46Z","timestamp":1787510026372,"version":"build-2736575974"},"reference-count":17,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2007,6,8]],"date-time":"2007-06-08T00:00:00Z","timestamp":1181260800000},"content-version":"vor","delay-in-days":2259,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Interven Cardiology"],"published-print":{"date-parts":[[2001,4]]},"abstract":"<jats:p>\n                    <jats:italic>The successful employment of embolization coils for transcatheter occlusion of the patent ductus arteriosus (PDA) has resulted in acceptance of transcatheter occlusion as the treatment of choice for small to medium\u2010sized PDAs. The Duct\u2010Occlud device was developed to further improve the technique by utilizing a controlled release mechanism and coil shape specifically designed for the geometly of the ductus arteriosus. Clinical studies have demonstrated excellent efficacy with low embolization rates and low incidences of complications. Newer modifications have been designed for occlusion of larger PDAs and subaortic ventricular septal defects, and preliminary clinical results have been promising<\/jats:italic>\n                    . (J Interven Cardiol 2001;14:231\u2013238)\n                  <\/jats:p>","DOI":"10.1111\/j.1540-8183.2001.tb00741.x","type":"journal-article","created":{"date-parts":[[2007,6,8]],"date-time":"2007-06-08T23:43:12Z","timestamp":1181346192000},"page":"231-238","source":"Crossref","is-referenced-by-count":17,"title":["The Duct\u2010Occlud Device: Design, Clinical Results, and Future Directions"],"prefix":"10.1111","volume":"14","author":[{"given":"JOHN W.","family":"MOORE","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DOUGLAS J.","family":"SCHNEIDER","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DOREEN","family":"DIMEGLIO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,6,8]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)90514-Y"},{"key":"e_1_2_1_3_2","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/S0033-8389(22)01768-7","article-title":"Catheter closure of patent ductus arteriosus. 62 cases treated without thoracotomy","volume":"9","author":"Portsmann W","year":"1971","journal-title":"Radiol Clin North Am"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.75.3.583"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.88.3.1119"},{"key":"e_1_2_1_6_2","first-page":"380","article-title":"The PDA coil registry: Report of the first 535 procedures (abstract)","volume":"9","author":"Loyd TR","year":"1995","journal-title":"Circulation"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.76.6.536"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-8703(97)70158-3"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(94)90451-0"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(96)90603-7"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-726X(199904)46:4<434::AID-CCD9>3.0.CO;2-N"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.eurheartj.a015265"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(97)00730-3"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-726X(200003)49:3<301::AID-CCD16>3.0.CO;2-V"},{"key":"e_1_2_1_15_2","unstructured":"Redel DA and European Duct\u2010Occlud Study Members Personal Communication for FDA Phase I Summary Report April 7 2000."},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-726X(200101)52:1<74::AID-CCD1018>3.0.CO;2-F"},{"key":"e_1_2_1_17_2","unstructured":"L\u00eaTP FreudenthalF HoffstetterR.Transcatheter occlusion of PDA using detachable nitinol coil. (abstract) The Fourth Pediatric Interventional Cardiac Symposium 2000 Chicago Illinois."},{"key":"e_1_2_1_18_2","unstructured":"L\u00eaTP VaessenP FreudenthalF.Interventional closure of subaortic VSD using a retrievable nickel\u2010titanium coil: Report on an animal study. (abstract) The Fourth Pediatric Interventional Cardiac Symposium September 2427 2000 Chicago Illinois."}],"container-title":["Journal of Interventional Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8183.2001.tb00741.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8183.2001.tb00741.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,19]],"date-time":"2023-11-19T06:58:48Z","timestamp":1700377128000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8183.2001.tb00741.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,4]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2001,4]]}},"alternative-id":["10.1111\/j.1540-8183.2001.tb00741.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8183.2001.tb00741.x","archive":["Portico"],"relation":{},"ISSN":["0896-4327","1540-8183"],"issn-type":[{"value":"0896-4327","type":"print"},{"value":"1540-8183","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,4]]}}}