{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T05:26:04Z","timestamp":1697088364908},"reference-count":10,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2004,2,26]],"date-time":"2004-02-26T00:00:00Z","timestamp":1077753600000},"content-version":"vor","delay-in-days":25,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Interven Cardiology"],"published-print":{"date-parts":[[2004,2]]},"abstract":"<jats:p> <jats:italic>\n            <jats:bold>Background:<\/jats:bold> We present a new one\u2010wire technique for balloon aortic valvuloplasty and discuss possible advantages of this technique over other techniques.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Methods:<\/jats:bold> The records of 16 patients who underwent 18 procedures were reviewed.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Technique:<\/jats:bold> A floppy\u2010tipped, nitinol wire (Ultra\u2010Select, Microvena Corp., White Bear Lake, MN) is placed across the aortic valve through a guide\/measurement catheter positioned in the aortic root. The guide catheter is then removed, and the balloon catheter is positioned. Balloon dilation is then performed.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Results:<\/jats:bold> Predilation all patients had 0\u20131+ aortic insufficiency (AI). Four of 18 procedures resulted in an increase of &gt;1 grade of AI, leaving 14 of 18 with \u22641 grade increase in AI. The mean gradient reduction achieved was 65%.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Follow\u2010up:<\/jats:bold> Eighty\u2010seven percent of the procedures have required no further intervention.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Conclusion:<\/jats:bold> The ease and simplicity of the procedure may reduce the risk of increasing AI, decrease fluoroscopy time, and arterial access time.<\/jats:italic> (J Interven Cardiol 2004;17:17\u201319)<\/jats:p>","DOI":"10.1111\/j.1540-8183.2004.01121.x","type":"journal-article","created":{"date-parts":[[2004,2,26]],"date-time":"2004-02-26T20:46:34Z","timestamp":1077828394000},"page":"17-19","source":"Crossref","is-referenced-by-count":0,"title":["One\u2010Wire Technique for Performance of Balloon Aortic Valvuloplasty"],"prefix":"10.1111","volume":"17","author":[{"given":"SHERRI","family":"S. BAKER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MARTIN P.","family":"O'LAUGHLIN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,2,26]]},"reference":[{"key":"e_1_2_7_2_2","first-page":"1087","volume-title":"Heart Disease in Infants, Children and Adolescents Including the Fetus and Young Adult","author":"Friedman WF","year":"1995"},{"key":"e_1_2_7_3_2","first-page":"I\u201047","article-title":"Clinical course in aortic stenosis","volume":"56","author":"Wagner HR","year":"1977","journal-title":"Circulation"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(84)90709-4"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(99)80295-1"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(90)92839-T"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0304(199711)42:3<328::AID-CCD24>3.0.CO;2-G"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)90457-N"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810280208"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(97)89395-2"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(90)91388-M"}],"container-title":["Journal of Interventional Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8183.2004.01121.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8183.2004.01121.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T00:09:26Z","timestamp":1697069366000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8183.2004.01121.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,2]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2004,2]]}},"alternative-id":["10.1111\/j.1540-8183.2004.01121.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8183.2004.01121.x","archive":["Portico"],"relation":{},"ISSN":["0896-4327","1540-8183"],"issn-type":[{"value":"0896-4327","type":"print"},{"value":"1540-8183","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,2]]}}}