{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T19:04:45Z","timestamp":1791918285183,"version":"4.3.4"},"reference-count":24,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2007,1,30]],"date-time":"2007-01-30T00:00:00Z","timestamp":1170115200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Interven Cardiology"],"published-print":{"date-parts":[[2007,2]]},"abstract":"<jats:p> <jats:italic>\n            <jats:bold>Objectives:<\/jats:bold> To evaluate the safety and efficacy of a double\u2010wire technique in carotid artery stenting (CAS) with a distal occlusion balloon system, PercuSurge GuardWire.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Methods:<\/jats:bold> Fifty\u2010one consecutive patients with 53 de novo lesions were scheduled to undergo balloon\u2010protected CAS with the \u201cdouble\u2010wire technique,\u201d the use of two wires, one for independent predilatation and the other for stent implantation.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Results:<\/jats:bold> Fifty consecutive patients underwent a total of 52 balloon\u2010protected CAS except for 1 patient with one lesion that could not be accessed. The use of a 1.5\u2010mm coronary balloon was necessary in only 2 cases (3.8%) to let the PercuSurge GuardWire cross critically stenotic lesions. The placement of the PercuSurge GuardWire into the internal carotid artery was successful in all cases. Technical success was obtained in all cases. Fifty lesions (96.2%) were treated with one inflation of the distal occlusion balloon during the entire procedure consisting of predilatation, stent implantation, and aspiration, and among them three lesions (5.8%) required postdilatation. The mean occlusion time of cerebral blood flow for 50 lesions was 266 \u00b1 37 seconds. Out of 50 procedures, 45 (90.0%) had occlusion times of 300 seconds or less. Neurological intolerance requiring intravenous anesthesia was seen in 4 cases (7.7%) and periprocedural neurological complication in 2 cases (3.8%).<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Conclusions:<\/jats:bold> The \u201cdouble\u2010wire technique\u201d is safe and effective for the shortening of occlusion time during predilatation, stent implantation, and aspiration, leading to satisfactory technical and clinical outcomes, in most cases. This technique should be considered for balloon\u2010protected CAS using the PercuSurge GuardWire.<\/jats:italic> <\/jats:p>","DOI":"10.1111\/j.1540-8183.2007.00218.x","type":"journal-article","created":{"date-parts":[[2007,2,2]],"date-time":"2007-02-02T21:44:24Z","timestamp":1170452664000},"page":"55-62","source":"Crossref","is-referenced-by-count":9,"title":["Double\u2010Wire Technique in Balloon\u2010Protected Carotid Artery Stenting"],"prefix":"10.1111","volume":"20","author":[{"given":"OSAMI","family":"KAWARADA","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"YOSHIAKI","family":"YOKOI","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KAZUSHI","family":"TAKEMOTO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"NOBUYUKI","family":"MORIOKA","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,1,30]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)01692-3"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/hs0202.102337"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000081000.23561.61"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjmed.2003.09.043"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2005.05.082"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20061"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20235"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20525"},{"key":"e_1_2_5_10_2","first-page":"869","article-title":"New triple coaxial catheter system for carotid angioplasty with cerebral protection","volume":"11","author":"Theron J","year":"1990","journal-title":"Am J Neuroradiol"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.201.3.8939208"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1583\/1074-6218(1999)006<0321:CSWCPF>2.0.CO;2"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20651"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20062"},{"key":"e_1_2_5_15_2","unstructured":"KawaradaO YokoiY.Renal guide catheter seating in tortuous aorta by two wire technique.http:\/\/EuroPCRonline.com"},{"key":"e_1_2_5_16_2","first-page":"1375","article-title":"Techniques for intracranial stent navigation in patients with tortuous vessels","volume":"26","author":"Lee TH","year":"2005","journal-title":"Am J Neuroradiol"},{"key":"e_1_2_5_17_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199108153250701"},{"key":"e_1_2_5_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2005.02.067"},{"key":"e_1_2_5_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20155"},{"key":"e_1_2_5_20_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000135763.62131.6a"},{"key":"e_1_2_5_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.10645"},{"key":"e_1_2_5_22_2","doi-asserted-by":"publisher","DOI":"10.1161\/hc4801.100353"},{"key":"e_1_2_5_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)02045-4"},{"key":"e_1_2_5_24_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000013947.17575.B3"},{"key":"e_1_2_5_25_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.10776"}],"container-title":["Journal of Interventional Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8183.2007.00218.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8183.2007.00218.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T16:21:41Z","timestamp":1697041301000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8183.2007.00218.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,1,30]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2007,2]]}},"alternative-id":["10.1111\/j.1540-8183.2007.00218.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8183.2007.00218.x","archive":["Portico"],"relation":{},"ISSN":["0896-4327","1540-8183"],"issn-type":[{"value":"0896-4327","type":"print"},{"value":"1540-8183","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,1,30]]}}}