{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T05:08:58Z","timestamp":1781500138305,"version":"3.54.1"},"reference-count":17,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,3,1]],"date-time":"2009-03-01T00:00:00Z","timestamp":1235865600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Interven Cardiology"],"published-print":{"date-parts":[[2009,6]]},"abstract":"<jats:p> <jats:italic>\n            <jats:bold>Background:<\/jats:bold> The ubiquitous use of less invasive therapeutic angiographic procedures has created the milieu for long\u2010term occupational risk of cancer and genetic defects. This study set out to determine the relative effectiveness of redundant radiation protective barriers and their impact on operator total\u2010body\u2010ionizing radiation exposure in the catheterization suite.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Methods:<\/jats:bold> Thermolucent dosimeter x\u2010irradiation was measured inside and outside personal and movable protective barriers used concurrently during 50 consecutive procedures by a single operator. Additionally, the entrance\/exit doses were recorded on the back and chest for all patients to provide insight into radiation scatter patterns.<\/jats:italic> <\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Results:<\/jats:bold> The x\u2010ray beam had an average 90.8% decrement in energy traversing the patient's chest when entrance and exit doses were compared, suggesting a 3.3\u2010fold greater operator scatter radiation exposure below the table compared with that above the table. All 0.5\u2010mm lead equivalent personal barriers reduced operator exposure by 72\u201395<\/jats:italic>%, <jats:italic>whereas the 1.0\u2010mm leaded personal barrier (overlapping gown) reduced exposure by 96%. The 0.75\u2010mm leaded glasses reduced exposure to the left eye by 67%. A leaded left\u2010hand glove reduced exposure by only 20%. The effective calculated operator radiation exposure risk reduction provided by the use of personal and movable barriers reduced the theoretical risk of fatal or nonfatal cancer by 22\u2010fold while decreasing potential severe genetic effect by 25\u2010fold in comparison to movable barriers alone.<\/jats:italic><\/jats:p><jats:p> <jats:italic>\n            <jats:bold>Conclusions:<\/jats:bold> The optimal use of combined personal and movable (redundant) lead barriers results in a significant reduction in total\u2010body operator radiation exposure in the catheterization laboratory. The use of redundant barriers in the catheterization suite is associated with a dramatic theoretical long\u2010term occupational risk reduction and should be encouraged<\/jats:italic>.<\/jats:p>","DOI":"10.1111\/j.1540-8183.2009.00433.x","type":"journal-article","created":{"date-parts":[[2009,3,2]],"date-time":"2009-03-02T02:56:09Z","timestamp":1235962569000},"page":"299-307","source":"Crossref","is-referenced-by-count":11,"title":["Redundant Protective Barriers: Minimizing Operator Occupational Risk"],"prefix":"10.1111","volume":"22","author":[{"given":"KARTHIK","family":"CHALLA","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"STAFFORD G.","family":"WARREN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"SUBHASH","family":"DANAK","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MARK C.","family":"BATES","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,5,31]]},"reference":[{"key":"e_1_2_6_2_2","unstructured":"SalahEl\u2010den AmanyYS GomaaMA.Dosimetry measurements around the angiography's units using TLD. The Second All African IRPA Regional Radiation Protection Congress 22\u201326 April 2007 151\u2013154."},{"key":"e_1_2_6_3_2","first-page":"784","article-title":"X\u2010ray as a irritant","volume":"7","author":"Kassabian MK","year":"1900","journal-title":"Am X-Ray J"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.2349\/biij.3.2.e31"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2482071800"},{"key":"e_1_2_6_6_2","unstructured":"ICRP Publication Recommendations of the International Commission on Radiological Protection. Oxford :Pergamon Press 1990;Paragraphs52\u201362."},{"key":"e_1_2_6_7_2","unstructured":"National Council on Radiation Protection and Measurements.Implementation of the principle of as low as reasonably achievable (ALARA) for medical and dental personnel. NCRP Report No. 107. Bethesda MD :NCRP 1990."},{"key":"e_1_2_6_8_2","first-page":"892","article-title":"Radiation safety in the practice of cardiology","volume":"31","author":"Limacher MC","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.16.5.8888398"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1051-0443(94)71456-1"},{"key":"e_1_2_6_11_2","first-page":"459","article-title":"Radiation safety in the cardiac catheterization laboratory","volume":"13","author":"Aldridge HE","year":"1997","journal-title":"Can J Cardiol"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810250304"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810100214"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1136\/heart.89.10.1205"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.58.5.925"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-726X(199906)47:2<229::AID-CCD23>3.0.CO;2-W"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.71.849.10195011"},{"key":"e_1_2_6_18_2","first-page":"124","article-title":"Radiation exposure and radiation protection in interventional cardiology","volume":"8","author":"Maeder M","year":"2005","journal-title":"Kardiovask Med"}],"container-title":["Journal of Interventional Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1540-8183.2009.00433.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1540-8183.2009.00433.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T16:33:01Z","timestamp":1697041981000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1540-8183.2009.00433.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,31]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2009,6]]}},"alternative-id":["10.1111\/j.1540-8183.2009.00433.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1540-8183.2009.00433.x","archive":["Portico"],"relation":{},"ISSN":["0896-4327","1540-8183"],"issn-type":[{"value":"0896-4327","type":"print"},{"value":"1540-8183","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,5,31]]}}}