{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T07:30:52Z","timestamp":1787729452959,"version":"build-2784847793"},"reference-count":81,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2012,1,26]],"date-time":"2012-01-26T00:00:00Z","timestamp":1327536000000},"content-version":"vor","delay-in-days":25,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Noninvasive Electrocardiol"],"published-print":{"date-parts":[[2012,1]]},"abstract":"<jats:p>We are in the midst of a rapidly evolving era of technology\u2010assisted medicine. The field of telemedicine provides the opportunity for highly individualized medical management in a way that has never been possible before. Evolving medical technologies using cardiac implantable devices with capabilities for remote monitoring permit evaluation of multiple parameters of cardiovascular physiology and risk, including cardiac rhythm, device function, blood pressure values, the presence of myocardial ischaemia, and the degree of compensation of congestive heart failure. Cardiac risk, device status, and response to therapies can now be assessed with these electronic systems of detection and reporting. This document reflects the extensive experience from investigators and innovators around the world who are shaping the evolution of this rapidly expanding field, focusing in particular on implantable pacemakers, implantable cardioverter defibrillators, devices for cardiac resynchronization therapy (both with and without defibrillation properties), loop recorders, and hemodynamic monitoring devices. This document covers the basic methodologies, guidelines for their use, experience with existing applications, and the legal and reimbursement aspects associated with their use. To adequately cover this important emerging topic, the International Society for Holter and Noninvasive Electrocardiology and the European Heart Rhythm Association combined their expertise in this field. We hope that the development of this field can contribute to improve care of our cardiovascular patients.<\/jats:p><jats:p><jats:bold>Ann Noninvasive Electrocardiol 2012;17(1):36\u201356<\/jats:bold><\/jats:p>","DOI":"10.1111\/j.1542-474x.2011.00484.x","type":"journal-article","created":{"date-parts":[[2012,1,26]],"date-time":"2012-01-26T08:58:40Z","timestamp":1327568320000},"page":"36-56","source":"Crossref","is-referenced-by-count":31,"title":["ISHNE\/EHRA Expert Consensus on Remote Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs)"],"prefix":"10.1111","volume":"17","author":[{"given":"Sergio","family":"Dubner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angelo","family":"Auricchio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan S.","family":"Steinberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panos","family":"Vardas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Stone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josep","family":"Brugada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryszard","family":"Piotrowicz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David L.","family":"Hayes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulus","family":"Kirchhof","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00fcnter","family":"Breithardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wojciech","family":"Zareba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudio","family":"Schuger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehmet K.","family":"Aktas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal","family":"Chudzik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suneet","family":"Mittal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niraj","family":"Varma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,1,26]]},"reference":[{"key":"e_1_2_11_2_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2003.t01-1-00229.x"},{"key":"e_1_2_11_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2008.01.001"},{"key":"e_1_2_11_4_2","unstructured":"Eucomedhttp:\/\/www.eucomed.org\/uploads\/_medical_technology\/facts_figures\/110518_statistics_for_cardiac_rhythm_management_products_20052010.pdf"},{"key":"e_1_2_11_5_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun122"},{"key":"e_1_2_11_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-008-9311-5"},{"key":"e_1_2_11_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eup110"},{"key":"e_1_2_11_8_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2001.00262.x"},{"key":"e_1_2_11_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.09554.x"},{"key":"e_1_2_11_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2004.00524.x"},{"key":"e_1_2_11_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.10.001"},{"key":"e_1_2_11_12_2","doi-asserted-by":"publisher","DOI":"10.1053\/eupc.2002.0302"},{"key":"e_1_2_11_13_2","first-page":"107","article-title":"Hartmann a potential applications of home monitoring in pacemaker therapy\u2014a review with emphasis on atrial fibrillation and congestive heart failure","volume":"2","author":"Stellbrink C","year":"2001","journal-title":"Prog Biomed Res"},{"key":"e_1_2_11_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.960633"},{"key":"e_1_2_11_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-008-0712-3"},{"key":"e_1_2_11_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-006-1304-8"},{"issue":"1","key":"e_1_2_11_17_2","first-page":"S2","article-title":"Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: Analysis of a worldwide database","volume":"30","author":"Lazarus A","year":"2007","journal-title":"Pacing Clin Electrophysiol"},{"key":"e_1_2_11_18_2","doi-asserted-by":"publisher","DOI":"10.1023\/B:JICE.0000042356.52369.89"},{"key":"e_1_2_11_19_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eum289"},{"key":"e_1_2_11_20_2","first-page":"505","article-title":"Technical and practical aspects of remote monitoring of implantable cardioverter\u2010defibrillator patients in Poland\u2014Preliminary results","volume":"67","author":"Przybylski A","year":"2009","journal-title":"Kardiol Pol"},{"key":"e_1_2_11_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.00071.x"},{"key":"e_1_2_11_22_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehq278"},{"key":"e_1_2_11_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehp298"},{"key":"e_1_2_11_24_2","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1093\/europace\/eum120","article-title":"HRS\/EHRA\/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"9","author":"Calkins H","year":"2007","journal-title":"Europace"},{"key":"e_1_2_11_25_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000131269.69502.d9"},{"key":"e_1_2_11_26_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.104.518837"},{"key":"e_1_2_11_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2006.07.030"},{"key":"e_1_2_11_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00737.x"},{"key":"e_1_2_11_29_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehi647"},{"key":"e_1_2_11_30_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.109.877852"},{"key":"e_1_2_11_31_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehm358"},{"key":"e_1_2_11_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2004.12.015"},{"key":"e_1_2_11_33_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eup097"},{"key":"e_1_2_11_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2008.01320.x"},{"key":"e_1_2_11_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2011.01.039"},{"key":"e_1_2_11_36_2","first-page":"1","article-title":"Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: Results from the PICTURE registry","volume":"19","author":"Edvardsson N","year":"2010","journal-title":"Europace"},{"key":"e_1_2_11_37_2","first-page":"109","article-title":"Prediction of fatal or near fatal cardiac arrhythmia events in patients with depressed left ventricular function after acute myocardial infarction. Results of the cardiac arrhythmias and risk stratification after acute myocardial infarction (CARISMA) study","volume":"10","author":"Huikuri HV","year":"2009","journal-title":"Eur Heart J"},{"key":"e_1_2_11_38_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun350"},{"key":"e_1_2_11_39_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun010"},{"key":"e_1_2_11_40_2","first-page":"241","article-title":"A prospective multicenter comparison trial of home monitoring against regular follow\u2010up in MADIT II","volume":"33","author":"Elsner C","year":"2006","journal-title":"Comput Cardiol"},{"key":"e_1_2_11_41_2","first-page":"131","article-title":"Home telemonitoring in patients with chronic heart failure: A chance to improve patient care?","volume":"107","author":"Schmidt S","year":"2010","journal-title":"Dtsch Arztebl Int"},{"key":"e_1_2_11_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2008.06.028"},{"key":"e_1_2_11_43_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun009"},{"key":"e_1_2_11_44_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehl495"},{"key":"e_1_2_11_45_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-006-0390-y"},{"key":"e_1_2_11_46_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.00083.x"},{"key":"e_1_2_11_47_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02314.x"},{"key":"e_1_2_11_48_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.110.951962"},{"key":"e_1_2_11_49_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.937409"},{"key":"e_1_2_11_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2006.02.011"},{"key":"e_1_2_11_51_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.295.16.1929"},{"key":"e_1_2_11_52_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2001.01046.x"},{"key":"e_1_2_11_53_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2008.02288.x"},{"key":"e_1_2_11_54_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hfc.2010.12.005"},{"key":"e_1_2_11_55_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurjhf\/hfp022"},{"key":"e_1_2_11_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cardfail.2006.12.004"},{"key":"e_1_2_11_57_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.104.492207"},{"key":"e_1_2_11_58_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.107.702191"},{"key":"e_1_2_11_59_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(11)60101-3"},{"key":"e_1_2_11_60_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00648.x"},{"key":"e_1_2_11_61_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000057981.70380.45"},{"key":"e_1_2_11_62_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.109.849638"},{"key":"e_1_2_11_63_2","unstructured":"The IMPACT of Biotronik home monitoring guided anticoagulation on stroke risk in patients with implanted ICD and CRT\u2010D devices.http:\/\/NCT00559988@clinicaltrials.gov."},{"key":"e_1_2_11_64_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.108.838474"},{"key":"e_1_2_11_65_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun250"},{"issue":"1","key":"e_1_2_11_66_2","first-page":"i56","article-title":"Home monitoring for pacemaker follow\u2010up: Results of randomized COMPAS trial","volume":"12","author":"Mabo P","year":"2010","journal-title":"Europace"},{"key":"e_1_2_11_67_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euq046"},{"key":"e_1_2_11_68_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2010.05.015"},{"key":"e_1_2_11_69_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02480.x"},{"key":"e_1_2_11_70_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2006.02.011"},{"key":"e_1_2_11_71_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-006-1302-x"},{"key":"e_1_2_11_72_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun203"},{"key":"e_1_2_11_73_2","doi-asserted-by":"publisher","DOI":"10.1109\/SP.2008.31"},{"key":"e_1_2_11_74_2","unstructured":"Wireless ICD programming vulnerable to hackers report claims.http:\/\/www.theheart.org\/article\/847781.do(accessed date 13 March 2011)."},{"key":"e_1_2_11_75_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehq203"},{"key":"e_1_2_11_76_2","first-page":"596","article-title":"Remote monitoring of cardiovascular implantable electronic devices. Prerequisite or luxury?","volume":"139","author":"Sticherling C","year":"2009","journal-title":"Swiss Med Wkly"},{"key":"e_1_2_11_77_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMp0912062"},{"key":"e_1_2_11_78_2","unstructured":"ColechinE ReayC BousfiledD et al.Implantable cardiac devices with remote monitoring facilities. NHS Purchasing and Supply Agency Centre for Evidence\u2010based Purchasing. 2009. Policy and Innovation Directorate of the NHS Purchasing and Supply Agency CEP09010."},{"key":"e_1_2_11_79_2","volume-title":"Remote Monitoring for Patients with Implanted Defibrillators","author":"Vinck I","year":"2010"},{"key":"e_1_2_11_80_2","unstructured":"Medical Services Advisory Committee. Remote monitoring systems for patients with implanted cardiac devices; June 2008. MSAC Application 1111. Retrieved on February 2011 from:http:\/\/www.health.gov.au\/internet\/msac\/publishing.nsf\/Content\/115CC907F00447B3CA2575AD0082FD6C\/$File\/MSAC%201111%20Report_FINAL%2028%20October%202008.pdf"},{"key":"e_1_2_11_81_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.08.017"},{"key":"e_1_2_11_82_2","doi-asserted-by":"publisher","DOI":"10.1017\/S0266462309990882"}],"container-title":["Annals of Noninvasive Electrocardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1542-474X.2011.00484.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1542-474X.2011.00484.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T00:24:28Z","timestamp":1698711868000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1542-474X.2011.00484.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1]]},"references-count":81,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,1]]}},"alternative-id":["10.1111\/j.1542-474X.2011.00484.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1542-474x.2011.00484.x","archive":["Portico"],"relation":{},"ISSN":["1082-720X","1542-474X"],"issn-type":[{"value":"1082-720X","type":"print"},{"value":"1542-474X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,1]]}}}