{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T03:09:07Z","timestamp":1795144147937,"version":"4.10.3"},"reference-count":26,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,11,4]],"date-time":"2009-11-04T00:00:00Z","timestamp":1257292800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Neuroimaging"],"published-print":{"date-parts":[[2010,7]]},"abstract":"<jats:sec><jats:title>ABSTRACT<\/jats:title><\/jats:sec><jats:sec><jats:title>BACKGROUND<\/jats:title><jats:p> <jats:bold>Transcranial Doppler (TCD) is widely applied to evaluate the intracranial large artery stenosis. We aimed to evaluate the accuracy of TCD in detecting siphon internal carotid artery (SICA) stenosis against digital subtraction angiography (DSA).<\/jats:bold> <\/jats:p><\/jats:sec><jats:sec><jats:title>METHODS<\/jats:title><jats:p> <jats:bold>A total of 145 patients with TCD and DSA performed were recruited. The SICA and other intracranial arteries were evaluated through transorbital and transtemporal acoustic window by TCD. We defined the best cutoff value for significant SICA stenosis by receiver\u2010operating characteristic (ROC) curve analyses and calculated the sensitivity, specificity, and positive and negative predictive values (PPV and NPV).<\/jats:bold> <\/jats:p><\/jats:sec><jats:sec><jats:title>RESULTS<\/jats:title><jats:p> <jats:bold>Mean age of the patients was 65.7 years (range 28\u201088 years) and 75.1% (109\/145) were men. The peak systolic velocity (PSV) = 120 cm\/second had the largest area under the ROC curve (area under the ROC curve = .868) compared with the MFV = 70 cm\/second and MFV = 80 cm\/second (area under the ROC curve = .822 and .845). So the criteria for SICA stenoses were defined as PSV = 120 cm\/second plus additional parameters (abnormal spectrum, circumscribed velocity changes, or side\u2010to\u2010side difference). Twenty\u2010nine patients were diagnosed with SICA stenosis or occlusion on TCD. Fourteen patients had abnormal TCD findings that were not confirmed by DSA. One patient with normal TCD but DSA showed mild (40%) stenoses. Accuracy parameters for TCD were as follows: sensitivity = 96.7% (95% confidence interval [CI]= 80.9\u201099.8), specificity = 93.9% (95% CI = 89.9\u201096.4), PPV = 65.9% (95% CI = 50.0\u201079.1), NPV = 99.6% (95% CI = 97.2\u20101.0). Most false\u2010positive patients (11 of 15 patients) had other significant intracranial large arteries lesions.<\/jats:bold> <\/jats:p><\/jats:sec><jats:sec><jats:title>CONCLUSIONS<\/jats:title><jats:p> <jats:bold>The criteria have limited but acceptable sensitivity and specificity in detecting SICA stenoses. Abnormal findings of siphon carotid on TCD require further clarification.<\/jats:bold> <\/jats:p><\/jats:sec>","DOI":"10.1111\/j.1552-6569.2009.00434.x","type":"journal-article","created":{"date-parts":[[2009,11,4]],"date-time":"2009-11-04T16:02:01Z","timestamp":1257350521000},"page":"234-239","source":"Crossref","is-referenced-by-count":13,"title":["Detection of the Siphon Internal Carotid Artery Stenosis: Transcranial Doppler versus Digital Subtraction Angiography"],"prefix":"10.1111","volume":"20","author":[{"given":"Yong","family":"You","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qing","family":"Hao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Leung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent","family":"Mok","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangyan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alex","family":"Lau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Howan","family":"Leung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ka Sing","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,7,12]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.31.11.2641"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/jon199444182"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/hs1201.099652"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/hs0202.102602"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.29.6.1144"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/jon199334242"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/jon20001011"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1552-6569.2004.tb00256.x"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0404.1999.tb00660.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1552-6569.2006.00088.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/ana.410280507"},{"key":"e_1_2_6_13_2","first-page":"26","volume-title":"Transcranial Doppler","author":"Fujioko KA","year":"1992"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0301-5629(90)90039-F"},{"key":"e_1_2_6_15_2","first-page":"591","article-title":"Transorbital color Doppler flow imaging of the carotid siphon and major arteries at the base of the brain","volume":"16","author":"Hu HH","year":"1995","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_2_6_16_2","first-page":"75","volume-title":"Non\u2010Invasive Assessment of the Cerebral Circulation in Cerebrovascular Disease. Frontiers of Clinical Neuroscience Series","author":"Angelstein EB","year":"1988"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.20.1.1"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.17.5.913"},{"key":"e_1_2_6_19_2","first-page":"A16","article-title":"Transcranial Doppler sonography in cerebrovascular disease","volume":"16","author":"Von Reuten GM","year":"1985","journal-title":"Stroke"},{"key":"e_1_2_6_20_2","first-page":"108","article-title":"Comparison of cerebral angiography and transcranial Doppler sonography in acute stroke","volume":"88","author":"Carmelingo M","year":"1993","journal-title":"Acta Neurol Scand"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.25.10.1931"},{"key":"e_1_2_6_22_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/j.1552-6569.2002.tb00083.x","article-title":"Screening for intracranial stenosis with transcranial Doppler: the accuracy of mean flow velocity thresholds","volume":"12","author":"Felberg RA","year":"2002","journal-title":"J Neuroimaging"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/jcu.10150"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.19.11.1445"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.21.11.1573"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.22.4.533"},{"key":"e_1_2_6_27_2","first-page":"113","volume-title":"Recent Advances in Neurosonology","author":"Wong WJ","year":"1992"}],"container-title":["Journal of Neuroimaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1552-6569.2009.00434.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1552-6569.2009.00434.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,2]],"date-time":"2023-11-02T16:05:33Z","timestamp":1698941133000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1552-6569.2009.00434.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,7]]}},"alternative-id":["10.1111\/j.1552-6569.2009.00434.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1552-6569.2009.00434.x","archive":["Portico"],"relation":{},"ISSN":["1051-2284","1552-6569"],"issn-type":[{"value":"1051-2284","type":"print"},{"value":"1552-6569","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7]]}}}