{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T13:41:37Z","timestamp":1782826897619,"version":"3.54.5"},"reference-count":27,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2009,12,10]],"date-time":"2009-12-10T00:00:00Z","timestamp":1260403200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Forensic Sciences"],"published-print":{"date-parts":[[2010,1]]},"abstract":"<jats:p><jats:bold>Abstract:\u2002<\/jats:bold> A significant amount of research has been conducted into the use of stable isotopes to assist in determining the origin of various materials. The research conducted in the forensic field shows the potential of isotope ratio mass spectrometry (IRMS) to provide a level of discrimination not achievable utilizing traditional forensic techniques. Despite the research there have been few, if any, publications addressing the validation and measurement uncertainty of the technique for forensic applications. This study, the first in a planned series, presents validation data for the measurement of bulk nitrogen isotope ratios in ammonium nitrate (AN) using the DELTA<jats:sup>plus<\/jats:sup>XP (Thermo Finnigan) IRMS instrument equipped with a ConFlo III interface and FlashEA\u2122 1112 elemental analyzer (EA). Appropriate laboratory standards, analytical methods and correction calculations were developed and evaluated. A validation protocol was developed in line with the guidelines provided by the National Association of Testing Authorities, Australia (NATA). Performance characteristics including: accuracy, precision\/repeatability, reproducibility\/ruggedness, robustness, linear range, and measurement uncertainty were evaluated for the measurement of nitrogen isotope ratios in AN. AN (99.5%) and ammonium thiocyanate (99.99+%) were determined to be the most suitable laboratory standards and were calibrated against international standards (certified reference materials). All performance characteristics were within an acceptable range when potential uncertainties, including the manufacturer\u2019s uncertainty of the technique and standards, were taken into account. The experiments described in this article could be used as a model for validation of other instruments for similar purposes. Later studies in this series will address the more general issue of demonstrating that the IRMS technique is scientifically sound and fit\u2010for\u2010purpose in the forensic explosives analysis field.<\/jats:p>","DOI":"10.1111\/j.1556-4029.2009.01241.x","type":"journal-article","created":{"date-parts":[[2009,12,10]],"date-time":"2009-12-10T18:04:03Z","timestamp":1260468243000},"page":"193-204","source":"Crossref","is-referenced-by-count":21,"title":["Forensic Analysis of Explosives Using Isotope Ratio Mass Spectrometry (IRMS)\u2014Part 1: Instrument Validation of the DELTA<sup>plus<\/sup>XP IRMS for Bulk Nitrogen Isotope Ratio Measurements"],"prefix":"10.1111","volume":"55","author":[{"given":"Sarah J.","family":"Benson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Lennard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David M.","family":"Hill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"Maynard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claude","family":"Roux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,1,4]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.forsciint.2005.03.012"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1080\/00085030.2006.10757136"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00442-004-1813-y"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1556-4029.2006.00123.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1520\/JFS2005077"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.2088"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.2424"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.1896"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.2153"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1520\/JFS2004513"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1080\/15275920500506964"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.forsciint.2006.06.013"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.forsciint.2005.11.008"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.2000"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.forsciint.2005.08.011"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1080\/15275920303485"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1255\/ejms.747"},{"key":"e_1_2_6_19_2","unstructured":"National Association of Testing Authorities Australia (NATA).Requirements for the format and content of test methods and recommended procedures for the validation of chemical test methods. Technical Note 17 December 1998http:\/\/www.nata.com.au\/index.cfm?objectid=DBCABA6C\u2010B07C\u2010AD52\u20100EB6E2E877F61885&productId=0870D30D\u2010BFF6\u20108A3C\u20104DC15F62FD07C8D4."},{"key":"e_1_2_6_20_2","volume-title":"Data analysis for chemistry","author":"Hibbert B","year":"2006"},{"key":"e_1_2_6_21_2","unstructured":"National Institute of Standards and Technology Report of Investigation Reference Materials 8547\u20108552.http:\/\/www.srmors.nist.gov\/tables\/view_table.cfm?table=104\u201010.htm."},{"key":"e_1_2_6_22_2","volume-title":"Reference and intercomparison materials for stable isotopes of light elements","author":"B\u00f6hlke JK","year":"1995"},{"key":"e_1_2_6_23_2","volume-title":"1112 Elemental analyser operating manual","author":"FlashEATM","year":"2001"},{"key":"e_1_2_6_24_2","unstructured":"International Standard ISO13528 Statistical methods for use in proficiency testing by interlaboratory comparisons. ISO First Edition 2005\u201009\u201001. Reference number: ISO 13528:2005(E) http:\/\/www.iso.org\/iso\/home.htm."},{"key":"e_1_2_6_25_2","unstructured":"National Association of Testing Authorities Australia (NATA).Guidelines for estimating and reporting measurement uncertainty of chemical test results. Technical Note 33\u2014June 2006.http:\/\/www.nata.asn.au\/index.cfm?objectid=DBCABA6C\u2010B07C\u2010AD52\u20100EB6E2E877F61885&productId=372DE8CF\u201008C7\u2010B791\u201082D9BCFE521BC83E."},{"key":"e_1_2_6_26_2","volume-title":"Guide to the expression of uncertainty in measurement (GUM)","author":"International Organization for Standardization (ISO)","year":"1993"},{"key":"e_1_2_6_27_2","volume-title":"Quantifying uncertainty in analytical measurement","author":"Eurachem CITAC","year":"2002"},{"key":"e_1_2_6_28_2","unstructured":"Thermo Finnigan Acceptance Protocol Issue December 2002."}],"container-title":["Journal of Forensic Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1556-4029.2009.01241.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1556-4029.2009.01241.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T21:20:41Z","timestamp":1697318441000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1556-4029.2009.01241.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["10.1111\/j.1556-4029.2009.01241.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1556-4029.2009.01241.x","archive":["Portico"],"relation":{},"ISSN":["0022-1198","1556-4029"],"issn-type":[{"value":"0022-1198","type":"print"},{"value":"1556-4029","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1]]}}}