{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,6,30]],"date-time":"2024-06-30T17:12:40Z","timestamp":1719767560092},"reference-count":25,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,5,27]],"date-time":"2009-05-27T00:00:00Z","timestamp":1243382400000},"content-version":"vor","delay-in-days":4378,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Ophthalmologica Scandinavica"],"published-print":{"date-parts":[[1997,6]]},"abstract":"<jats:p>The Grating Disc (GD) is a simplified visual test designed for children 18 months to 4 \u02dc 5 years. Two hundred pediatric patients (103 males, 97 females; aged 5 months to &gt; 6 years) participated in this study to determined how the GD visual acuity (VA) correlates with the Preferential Looking (PL) VA. Forty\u2010six percent of the patients had varying degrees of retinopathy of prematurity. The PL acuity was determined using the up\u2010and\u2010down staircase procedure. To measure GD acuity, six GDs with vertical gratings equivalent to acuities of 20\/1920 to 20\/60 were used. The examiner presented one GD simultaneously with the homogeneous disc from 57 cm. The VA was determined by the finest GD that the child could differentiate from the homogeneous disc. The overall correlation between the PL and the GD acuities was very high (R<jats:sup>2<\/jats:sup> = 0.861). One hundred twenty\u2010eight patients (64.0%) had an acuity agreement within 0.5 octave and 178 (89.0%) patients were within 1.0 octave. When the PL acuity was \u2265 20\/100, the GD and PL acuities showed good agreement. When the PL acuity was poorer, the GD acuity was poorer than the PL acuity. Although the GD acuity tended to be lower than the PL acuity in severely visually impaired patients, the GD acuity agreed with the PL in most visual assessments of young children. GD testing could be a useful alternative when sophisticated assessment systems such as the PL are unavailable.<\/jats:p>","DOI":"10.1111\/j.1600-0420.1997.tb00770.x","type":"journal-article","created":{"date-parts":[[2009,5,28]],"date-time":"2009-05-28T00:00:40Z","timestamp":1243468840000},"page":"266-271","source":"Crossref","is-referenced-by-count":1,"title":["Five years' experience with the Grating Disc"],"prefix":"10.1111","volume":"75","author":[{"given":"Osamu","family":"Katsumi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sachiko","family":"Denno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siham G.","family":"Chedid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuo","family":"Hirose","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,5,27]]},"reference":[{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1964.00970010881017"},{"key":"e_1_2_1_3_1","first-page":"1142","article-title":"A behavioral method for efficient screening of visual acuity in young infants. I. Preliminary laboratory development","volume":"17","author":"Dobson V.","year":"1978","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_4_1","first-page":"43","article-title":"Pattern vision in young infants","volume":"8","author":"Fantz RL","year":"1958","journal-title":"Psychol Res"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02173307"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1986.01050200100060"},{"key":"e_1_2_1_7_1","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1542\/peds.19.6.1088","article-title":"An apparatus for grading the visual acuity of infants on the basis of optokinetic nystagmus","volume":"19","author":"Gormann J.","year":"1957","journal-title":"Pediatrics"},{"key":"e_1_2_1_8_1","first-page":"332","volume-title":"Visual Evoked Potentials in Man: New Developments","author":"Harter MR","year":"1977"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.3109\/13816818309007804"},{"key":"e_1_2_1_10_1","first-page":"420","article-title":"A new method to measure the pattern reversal visual evoked response in infants and young children","volume":"30","author":"Katsumi O.","year":"1987","journal-title":"Jpn J Ophthalmol"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1990.tb01918.x"},{"key":"e_1_2_1_12_1","first-page":"496","article-title":"Use of temporally modulated stripes in measuring visual acuity in infants and young children with severe visual impairment","volume":"34","author":"Katsumi O.","year":"1993","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_13_1","doi-asserted-by":"crossref","first-page":"305","DOI":"10.3928\/0191-3913-19920901-11","article-title":"Visual hand display (VHD) as an introductory procedure for measuring vision in infants and young children","volume":"29","author":"Kronheim JK","year":"1992","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"e_1_2_1_14_1","first-page":"566","article-title":"Assessment of vision in young children: a new operant approach yields estimates of acuity","volume":"19","author":"Mayer DL","year":"1980","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_15_1","first-page":"538","article-title":"Preferential looking acuity obtained with a staircase procedure in pediatric patients","volume":"23","author":"Mayer DL","year":"1982","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_16_1","first-page":"1152","article-title":"The acuity card procedure: a rapid test of infant acuity","volume":"26","author":"McDonald MA","year":"1985","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-349-11188-6_29"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(85)90217-2"},{"key":"e_1_2_1_19_1","first-page":"187","article-title":"The design of a new letter chart for measuring contrast sensitivity","volume":"2","author":"Pelli DG","year":"1988","journal-title":"Clin Vis Sci"},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(71)90147-7"},{"key":"e_1_2_1_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(83)34407-9"},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(78)90074-3"},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(73)90016-3"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(74)90018-2"},{"key":"e_1_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199101000-00006"},{"key":"e_1_2_1_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2044-8317.1965.tb00689.x"}],"container-title":["Acta Ophthalmologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0420.1997.tb00770.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0420.1997.tb00770.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T09:59:18Z","timestamp":1698400758000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0420.1997.tb00770.x"}},"subtitle":["A simplified method of evaluating vision in young children"],"short-title":[],"issued":{"date-parts":[[1997,6]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1997,6]]}},"alternative-id":["10.1111\/j.1600-0420.1997.tb00770.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0420.1997.tb00770.x","archive":["Portico"],"relation":{},"ISSN":["1395-3907","1600-0420"],"issn-type":[{"value":"1395-3907","type":"print"},{"value":"1600-0420","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,6]]}}}