{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T09:09:41Z","timestamp":1780564181501,"version":"3.54.1"},"reference-count":39,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2005,2,16]],"date-time":"2005-02-16T00:00:00Z","timestamp":1108512000000},"content-version":"vor","delay-in-days":15,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Ophthalmologica Scandinavica"],"published-print":{"date-parts":[[2005,2]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold>  <jats:bold>To compare posterior capsule opacification (PCO) after cataract surgery with implantation of two silicone intraocular lenses (IOLs) with different designs.<\/jats:bold> <\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold>  <jats:bold>We carried out a prospective, clinical study of 116 patients randomized to standardized phacoemulsification with implantation of CeeOn Edge (<jats:italic>n<\/jats:italic>\u2003=\u200357) or SI40NB (<jats:italic>n<\/jats:italic>\u2003=\u200359) IOLs. The follow\u2010up period was 3\u2003years. To evaluate PCO morphologically, digital images were obtained and analysed using evaluation of posterior capsule opacification computer software (<jats:sc>epco<\/jats:sc>). The neodymium:YAG (Nd:YAG) capsulotomy rate was recorded.<\/jats:bold> <\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold>  <jats:bold>At 2 and 3\u2003years, the eyes with SI40NB IOLs had significantly more PCO than those with the CeeOn Edge IOLs (p\u2003=\u20030.00014 and p\u2003=\u20030.002). Nine Nd:YAG capsulotomies were performed in the SI40NB group and none in the CeeOn Edge group. This difference was statistically significant (p\u2003=\u20030.003). In some patients a regression of PCO was noticed and confirmed using <jats:sc>epco<\/jats:sc>. Statistically less PCO was noted when the capsulorhexis rim was placed so that it covered all 360\u2003degrees of the optic of the IOL.<\/jats:bold> <\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold>  <jats:bold>A clinically and statistically significant difference in PCO development between CeeOn Edge and SI40NB IOLs at 2 and 3\u2003years postoperatively was found. These findings support earlier studies indicating that a sharp edge of the optic is a more important factor in IOL design than IOL material in the prevention of PCO.<\/jats:bold> <\/jats:p>","DOI":"10.1111\/j.1600-0420.2005.00408.x","type":"journal-article","created":{"date-parts":[[2005,2,16]],"date-time":"2005-02-16T22:55:20Z","timestamp":1108594520000},"page":"11-19","source":"Crossref","is-referenced-by-count":14,"title":["Three\u2010year follow\u2010up of posterior capsule opacification with two different silicone intraocular lenses"],"prefix":"10.1111","volume":"83","author":[{"given":"Karin","family":"Sundelin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hossein","family":"Shams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulf","family":"Stenevi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,2,16]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01360-3"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00353-5"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00589-3"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80448-8"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01980-2"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00795-9"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01209-9"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01490-6"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01460-8"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00136-0"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.116.12.1579"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1159\/000309402"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(99)00157-9"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.82.10.1182"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90047-7"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80301-X"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00323-0"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.81.10.862"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80026-0"},{"key":"e_1_2_7_21_1","first-page":"321","article-title":"Relationship between age at time of cataract extraction and time interval before capsulotomy for opacification","volume":"20","author":"Maltzman BA","year":"1989","journal-title":"Ophthalmic Surg"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(89)80110-5"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00050-6"},{"key":"e_1_2_7_24_1","first-page":"397","article-title":"Optic sharp edge or convexity: comparison of effects on posterior capsular opacification","volume":"40","author":"Nagata T","year":"1996","journal-title":"Jpn J Ophthalmol"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.1997.tb00149.x"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)80049-2"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01430-X"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01530-4"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00644-1"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00426-0"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(96)80278-1"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00481-5"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)02051-5"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(96)80277-X"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01019-7"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(98)97023-3"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00522-8"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01116-8"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80022-3"},{"key":"e_1_2_7_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80323-4"}],"container-title":["Acta Ophthalmologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0420.2005.00408.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0420.2005.00408.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T19:50:02Z","timestamp":1696967402000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0420.2005.00408.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,2]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2005,2]]}},"alternative-id":["10.1111\/j.1600-0420.2005.00408.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0420.2005.00408.x","archive":["Portico"],"relation":{},"ISSN":["1395-3907","1600-0420"],"issn-type":[{"value":"1395-3907","type":"print"},{"value":"1600-0420","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,2]]}}}