{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T10:11:35Z","timestamp":1762251095532},"reference-count":24,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2005,8,5]],"date-time":"2005-08-05T00:00:00Z","timestamp":1123200000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Ophthalmologica Scandinavica"],"published-print":{"date-parts":[[2005,12]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold>  <jats:bold>Visual field testing in children is always a challenge as testing is hampered by fatigue effects, easy distraction and lack of comprehension. For that reason new testing strategies for automated perimetry have mainly been evaluated on adults. We tested the feasibility and outcome of automated static perimetry in children in a standard clinical setting.<\/jats:bold> <\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold>  <jats:bold>Twenty\u2010eight children aged 5\u201314\u2003years were examined at the Twinfield perimeter, including healthy children, children with unilateral pathologies (normal eye tested) and children with strabismus. Fast threshold strategy (FT) and continuous light increment perimetry (CLIP) strategy were used in a randomized order. One eye per subject was examined and each test was performed twice.<\/jats:bold> <\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold>  <jats:bold>Reliable results were obtained in many children starting from the age of 8\u2003years. In children aged 13\u2003years and over, adult testing strategies were possible in most cases with good reproducibility. No significant difference was found between the children with strabismus and the other children. Mean sensitivity (MS) increased and fixation losses decreased as a function of age. Continuous light increment perimetry showed a lower number of abnormal fields and fewer false\u2010positive errors compared to FT.<\/jats:bold> <\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold>  <jats:bold>Automated static perimetry is possible in many children in a clinical setting using a commercially available Twinfield perimeter in a session of clinically practical duration. Test performance was not only dependent on age, but also on the child's maturity and ability to concentrate. Especially in children up to the age of 8\u2003years, testing with the ramp stimulus (CLIP) was easier than with a staircase strategy (FT).<\/jats:bold> <\/jats:p>","DOI":"10.1111\/j.1600-0420.2005.00526.x","type":"journal-article","created":{"date-parts":[[2005,11,28]],"date-time":"2005-11-28T10:24:09Z","timestamp":1133173449000},"page":"664-669","source":"Crossref","is-referenced-by-count":15,"title":["Feasibility and outcome of automated static perimetry in children using continuous light increment perimetry (CLIP) and fast threshold strategy"],"prefix":"10.1111","volume":"83","author":[{"given":"B. K.","family":"Wabbels","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Wilscher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,11,28]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.06.018"},{"key":"e_1_2_6_3_1","doi-asserted-by":"crossref","first-page":"347","DOI":"10.3928\/0191-3913-19971101-06","article-title":"Constriction of the visual field of children after early visual deprivation","volume":"34","author":"Bowering ER","year":"1997","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpa.2001.113840"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.79.3.267"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(69)90008-X"},{"key":"e_1_2_6_7_1","doi-asserted-by":"crossref","first-page":"39","DOI":"10.3928\/0191-3913-20040101-10","article-title":"Peripheral and central visual fields in 11\u2010year\u2010old children who had been born prematurely and at term","volume":"41","author":"Larsson E","year":"2004","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"e_1_2_6_8_1","first-page":"277","article-title":"Perimetry in young children","volume":"17","author":"Liao F","year":"1973","journal-title":"Jap J Ophthalmol"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01203713"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00415-2"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.117.1.94"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200408000-00004"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0420.2001.790508.x"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-0945"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1996.01100130421010"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.6.515"},{"key":"e_1_2_6_17_1","first-page":"266","article-title":"Visual field defects in children with congenital glaucoma","volume":"37","author":"De Souza EC","year":"2000","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1035479"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(97)00368-4"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(97)00369-6"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00180-1"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1528-1157.2002.17801.x"},{"key":"e_1_2_6_23_1","first-page":"177","volume-title":"Perimetry Update 2000\/2001.","author":"Wabbels B","year":"2001"},{"key":"e_1_2_6_24_1","first-page":"135","volume-title":"Perimetry Update 2002\/2003.","author":"Wabbels B","year":"2003"},{"key":"e_1_2_6_25_1","doi-asserted-by":"crossref","first-page":"151","DOI":"10.3928\/0191-3913-19910501-08","article-title":"Normative values for visual fields in 4\u2010 to 12\u2010year\u2010old children using kinetic perimetry","volume":"28","author":"Wilson M","year":"1991","journal-title":"J Pediatr Ophthalmol Strabismus"}],"container-title":["Acta Ophthalmologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0420.2005.00526.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0420.2005.00526.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T00:30:00Z","timestamp":1696984200000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0420.2005.00526.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11,28]]},"references-count":24,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2005,12]]}},"alternative-id":["10.1111\/j.1600-0420.2005.00526.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0420.2005.00526.x","archive":["Portico"],"relation":{},"ISSN":["1395-3907","1600-0420"],"issn-type":[{"value":"1395-3907","type":"print"},{"value":"1600-0420","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,11,28]]}}}