{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,15]],"date-time":"2024-09-15T22:06:06Z","timestamp":1726437966034},"reference-count":23,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2010,4,20]],"date-time":"2010-04-20T00:00:00Z","timestamp":1271721600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2010,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p><jats:bold>Objective: <\/jats:bold> To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre\u2010surgical implant planning using cadavers.<\/jats:p><jats:p><jats:bold>Materials and methods: <\/jats:bold> Six cadavers were used for the study using multi\u2010detector computed tomography (CT) operated at 120\u2003kV and the variable tube current of 80, 40, 20 and 10\u2003mA. A slice thickness of 0.625\u2003mm and pitch 1 were used. Multi\u2010planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours\/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80\u2003mA images based on the criteria: excellent, good, fair or non\u2010diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions.<\/jats:p><jats:p><jats:bold>Results: <\/jats:bold> The 40\u2003mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80\u2003mA images. Even the 20\u2003mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10\u2003mA images may not be accepted because of the obscured contour caused by image noise.<\/jats:p><jats:p><jats:bold>Conclusion: <\/jats:bold> Significant dose reduction by lowering mA can be utilized for pre\u2010surgical implant planning in multi\u2010detector CT.<\/jats:p><jats:p> <jats:bold>To cite this article:<\/jats:bold>\n          \u2028Koizumi H, Sur J, Seki K, Nakajima K, Sano T, Okano T. Effects of dose reduction on multi\u2010detector computed tomographic images in evaluating the maxilla and mandible for pre\u2010surgical implant planning: a cadaveric study.\u2028<jats:italic>Clin. Oral Impl. Res<\/jats:italic>. <jats:bold>21<\/jats:bold>, 2010; 830\u2013834.\u2028doi: 10.1111\/j.1600\u20100501.2010.01925.x<\/jats:p>","DOI":"10.1111\/j.1600-0501.2010.01925.x","type":"journal-article","created":{"date-parts":[[2010,4,20]],"date-time":"2010-04-20T08:49:25Z","timestamp":1271753365000},"page":"830-834","source":"Crossref","is-referenced-by-count":9,"title":["Effects of dose reduction on multi\u2010detector computed tomographic images in evaluating the maxilla and mandible for pre\u2010surgical implant planning: a cadaveric study"],"prefix":"10.1111","volume":"21","author":[{"given":"Hiroshi","family":"Koizumi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaideep","family":"Sur","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenji","family":"Seki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koh","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsukasa","family":"Sano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiro","family":"Okano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,7,7]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.2235592100"},{"key":"e_1_2_7_3_1","first-page":"1758","article-title":"Must radiation dose for CT of the maxilla and mandible be higher than that for conventional panoramic radiography?","volume":"17","author":"Diederichs C.G.","year":"1996","journal-title":"American Journal of Neuroradiology"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0901249"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s003300050062"},{"key":"e_1_2_7_6_1","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1007\/s00330-002-1652-3","article-title":"A new low\u2010dose CT examination compared with standard\u2010dose CT in the diagnosis of acute sinusitis","volume":"13","author":"Hagtvedt T.","year":"2003","journal-title":"European Journal of Radiology"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/01948454"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2263020205"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3057"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0720-048X(03)00002-0"},{"key":"e_1_2_7_11_1","unstructured":"International Commission on Radiological Protection (ICRP). (1990) Amsterdam:Elsevier."},{"volume-title":"Managing patient dose in computed tomography, Annals of the ICRP, Publication 87","year":"2001","author":"International Commission on Radiological Protection (ICRP)","key":"e_1_2_7_12_1"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.594903"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s003300050674"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2303021726"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0b013e318181fab5"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2008.03.018"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2481071451"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1834-7819.2008.00037.x"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.184.5.01841611"},{"key":"e_1_2_7_21_1","first-page":"533","article-title":"Comparison of image quality between conventional and low\u2010dose nonenhanced head CT","volume":"25","author":"Mullins M.E.","year":"2004","journal-title":"American Journal of Neuroradiology"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/14769929"},{"volume-title":"Dental Applications of Computerized Tomography: Surgical Planning for Implant Placement","year":"1998","author":"Rothman S.L.G.","key":"e_1_2_7_23_1"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2322031069"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0501.2010.01925.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0501.2010.01925.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T08:31:20Z","timestamp":1698741080000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0501.2010.01925.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,7]]},"references-count":23,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2010,8]]}},"alternative-id":["10.1111\/j.1600-0501.2010.01925.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0501.2010.01925.x","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"type":"print","value":"0905-7161"},{"type":"electronic","value":"1600-0501"}],"subject":[],"published":{"date-parts":[[2010,7,7]]}}}