{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T14:47:02Z","timestamp":1787496422159,"version":"build-2736575974"},"reference-count":16,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,2,22]],"date-time":"2009-02-22T00:00:00Z","timestamp":1235260800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Contact Dermatitis"],"published-print":{"date-parts":[[2009,3]]},"abstract":"<jats:p>\n                    <jats:bold>Background:\u2002<\/jats:bold>\n                    Cobalt, nickel, and chromium are important skin sensitizers. However, knowledge about cobalt exposure and causes of cobalt sensitization is limited.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Objectives:\u2002<\/jats:bold>\n                    To study release of cobalt, nickel, and chromium from some cobalt\u2010containing hard metal alloys and to test reactivity to the materials in cobalt\u2010sensitized patients.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:\u2002<\/jats:bold>\n                    Discs suitable for patch testing were made of some hard metal alloys. Cobalt, nickel, and chromium release from the materials was determined by immersion in artificial sweat (2\u2003min, 1\u2003hr, 1\u2003day, and 1\u2003week). Patch test reactivity to the discs and to serial dilutions of cobalt and nickel was assessed in previously patch\u2010tested dermatitis patients (19 cobalt positive and 18 cobalt\u2010negative controls).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:\u2002<\/jats:bold>\n                    All discs released cobalt, nickel, and chromium. Some discs released large amounts of cobalt (highest concentration: 290\u2003\u03bcg\/cm\n                    <jats:sup>2<\/jats:sup>\n                    \/week). Seven discs elicited three or more positive test reactions.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions:\u2002<\/jats:bold>\n                    The concentration of released cobalt was high enough to elicit allergic contact dermatitis in cobalt\u2010sensitized patients. As the materials in the discs are used in wear parts of hard metal tools, individuals with contact allergy to cobalt may develop hand eczema when handling such materials.\n                  <\/jats:p>","DOI":"10.1111\/j.1600-0536.2008.01497.x","type":"journal-article","created":{"date-parts":[[2009,2,23]],"date-time":"2009-02-23T00:09:58Z","timestamp":1235347798000},"page":"165-170","source":"Crossref","is-referenced-by-count":78,"title":["Cobalt\u2010containing alloys and their ability to release cobalt and cause dermatitis"],"prefix":"10.1111","volume":"60","author":[{"given":"Anneli","family":"Julander","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica","family":"Hinds\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lizbet","family":"Skare","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carola","family":"Lid\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,2,22]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/3-540-31301-X_32"},{"key":"e_1_2_6_3_2","doi-asserted-by":"crossref","first-page":"341","DOI":"10.2340\/0001555574344346","article-title":"Cross\u2010reactivity to metal compounds studied in guinea pigs induced with chromate or cobalt","volume":"74","author":"Lid\u00e9n C","year":"1994","journal-title":"Acta Derm Venereol"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1046-199X(00)90031-9"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2133.1996.tb07601.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2006.01063.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1983.tb04316.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/ajim.4700080419"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1998.tb05861.x"},{"key":"e_1_2_6_10_2","volume-title":"Manual of Contact Dermatitis","author":"Fregert S","year":"1981"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/3-540-31301-X_22"},{"key":"e_1_2_6_12_2","volume-title":"Reference Test Method for Release of Nickel from Products Intended to Come into Direct and Prolonged Contact with the Skin","author":"European Committee for Standardisation (CEN)","year":"1998"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1998.tb05912.x"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0536.2001.044003160.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1046-199X(99)90001-5"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0105-1873.2005.00523.x"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0105-1873.2006.00736.x"}],"container-title":["Contact Dermatitis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0536.2008.01497.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0536.2008.01497.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T20:00:39Z","timestamp":1697486439000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0536.2008.01497.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,2,22]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2009,3]]}},"alternative-id":["10.1111\/j.1600-0536.2008.01497.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0536.2008.01497.x","archive":["Portico"],"relation":{},"ISSN":["0105-1873","1600-0536"],"issn-type":[{"value":"0105-1873","type":"print"},{"value":"1600-0536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,2,22]]}}}