{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T13:20:14Z","timestamp":1792761614772,"version":"4.5.0"},"reference-count":40,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2010,4,23]],"date-time":"2010-04-23T00:00:00Z","timestamp":1271980800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Contact Dermatitis"],"published-print":{"date-parts":[[2010,5]]},"abstract":"<jats:p> <jats:italic>Background:<\/jats:italic> The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine\u2010tuned to estimate nickel release around the limit value of the EU Nickel Directive from products intended to come into direct and prolonged skin contact. Because assessments according to EN 1811 are expensive to perform, time consuming, and may destruct the test item, it should be of great value to know the accuracy of the DMG screening test.<\/jats:p><jats:p> <jats:italic>Objectives:<\/jats:italic> To evaluate the sensitivity and specificity of the DMG test.<\/jats:p><jats:p> <jats:italic>Methods:<\/jats:italic> DMG spot testing, chemical analysis according to the EN 1811 reference method, and X\u2010ray fluorescence spectroscopy (XRF) were performed concomitantly on 96 metallic components from earrings recently purchased in San Francisco.<\/jats:p><jats:p> <jats:italic>Results:<\/jats:italic> The sensitivity of the DMG test was 59.3% and the specificity was 97.5% based on DMG\u2010test results and nickel release concentrations determined by the EN 1811 reference method.<\/jats:p><jats:p> <jats:italic>Conclusions:<\/jats:italic> The DMG test has a high specificity but a modest sensitivity. It may serve well for screening purposes. Past exposure studies may have underestimated nickel release from consumer items.<\/jats:p>","DOI":"10.1111\/j.1600-0536.2010.01709.x","type":"journal-article","created":{"date-parts":[[2010,4,23]],"date-time":"2010-04-23T10:45:20Z","timestamp":1272019520000},"page":"279-288","source":"Crossref","is-referenced-by-count":123,"title":["Sensitivity and specificity of the nickel spot (dimethylglyoxime) test"],"prefix":"10.1111","volume":"62","author":[{"given":"Jacob P.","family":"Thyssen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lizbet","family":"Skare","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lennart","family":"Lundgren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Torkil","family":"Menn\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeanne D.","family":"Johansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Howard I.","family":"Maibach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carola","family":"Lid\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,4,23]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.2310\/6620.2008.06062"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2007.01220.x"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0105-1873.2005.00673.x"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2222.2007.02846.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0736-8046.2004.21306.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1984.tb00059.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0105-1873.2005.00494.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.2310\/6620.2007.07013"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2008.01350.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2008.01487.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2009.06.034"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1998.tb05861.x"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2008.01326.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2008.01363.x"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2133.1999.03106.x"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2009.01625.x"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0105-1873.2003.0128f.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMc0809293"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaad.2009.03.030"},{"key":"e_1_2_6_21_2","first-page":"149","volume-title":"Test for Metals, Cations and Anions of Metallo Acids. Spot Tests in Inorganic Analysis","author":"Feigl F.","year":"1958"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/3-540-31301-X_25"},{"issue":"4","key":"e_1_2_6_23_2","first-page":"128","article-title":"Evaluation of the dimethylglyoxime stick test for the detection of nickel","volume":"35","author":"Menn\u00e9 T","year":"1987","journal-title":"Derm Beruf Umwelt"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1987.tb01448.x"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2007.01096.x"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1990.tb00093.x"},{"key":"e_1_2_6_27_2","unstructured":"European Committee for Standardization.Screening tests for nickel release from alloys and coatings in items that come into direct and prolonged contact with the skin. CR12471 1\u201310 2002."},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1994.tb02023.x"},{"key":"e_1_2_6_29_2","doi-asserted-by":"crossref","first-page":"113","DOI":"10.2340\/000155555113115","article-title":"Leaching of nickel from stainless steel consumer commodities","volume":"55","author":"Katz S A","year":"1975","journal-title":"Acta Derm Venereol"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0048-9697(98)00345-3"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1993.tb03436.x"},{"key":"e_1_2_6_32_2","unstructured":"European Committee for Standardization.Reference test method for release of nickel from products intended to come into direct and prolonged contact with the skin (EN 1811). Ref.No. EN 1811: 1998 E 1998."},{"key":"e_1_2_6_33_2","first-page":"7","article-title":"Commission Regulation (EC) No 552\/2009 of 22 June 2009 amending Regulation (EC) No 1907\/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) as regards Annex XVII","volume":"64","author":"The Commission of the European Communities","year":"2009","journal-title":"Official J Eur Union"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaad.2008.03.017"},{"key":"e_1_2_6_35_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.308.6943.1552"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0536.2001.440102.x"},{"key":"e_1_2_6_37_2","first-page":"301","year":"2004","journal-title":"Official J Eur Union"},{"key":"e_1_2_6_38_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1984.tb00056.x"},{"key":"e_1_2_6_39_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1985.tb01056.x"},{"key":"e_1_2_6_40_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1994.tb01997.x"},{"key":"e_1_2_6_41_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1997.tb00314.x"}],"container-title":["Contact Dermatitis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0536.2010.01709.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0536.2010.01709.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T02:33:40Z","timestamp":1697510020000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0536.2010.01709.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,4,23]]},"references-count":40,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2010,5]]}},"alternative-id":["10.1111\/j.1600-0536.2010.01709.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0536.2010.01709.x","archive":["Portico"],"relation":{},"ISSN":["0105-1873","1600-0536"],"issn-type":[{"value":"0105-1873","type":"print"},{"value":"1600-0536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,4,23]]}}}