{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T02:33:29Z","timestamp":1787884409107,"version":"build-2784847793"},"reference-count":46,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2008,7,9]],"date-time":"2008-07-09T00:00:00Z","timestamp":1215561600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["European J Oral Sciences"],"published-print":{"date-parts":[[2008,8]]},"abstract":"<jats:p>The purpose of this <jats:italic>in vitro<\/jats:italic> study was to compare the load\u2010bearing capacity of posterior three\u2010unit fixed dental prostheses (FDP) produced with three different all\u2010ceramic framework materials: glass\u2010infiltrated alumina (ICA), glass\u2010infiltrated alumina strengthened with zirconia (ICZ), and yttria\u2010stabilized polycrystalline zirconia (YZ). Additionally, the influence on aging of mechanical cyclic fatigue loading and thermal cycling in water were evaluated. A total of 20 frameworks each were fabricated from ICA, ICZ, and YZ by a computer\u2010aided design (CAD)\/computer\u2010aided manufacturing (CAM) system. The framework designs were identical for all specimens. All frameworks were veneered with porcelain and cemented with glass\u2013ionomer. Prior to fracture testing, 10 FDP of each experimental group were subjected to thermal and mechanical cycling. Additionally, fractographic analysis was performed. Statistical analysis showed that FDP made from YZ had significantly higher load to failure, whereas no difference was found between the other two materials. Aging did not have a significant effect on the fracture load.<\/jats:p>","DOI":"10.1111\/j.1600-0722.2008.00551.x","type":"journal-article","created":{"date-parts":[[2008,7,9]],"date-time":"2008-07-09T15:24:45Z","timestamp":1215617085000},"page":"381-386","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":59,"title":["Load\u2010bearing capacity of all\u2010ceramic three\u2010unit fixed partial dentures with different computer\u2010aided design (CAD)\/computer\u2010aided manufacturing (CAM) fabricated framework materials"],"prefix":"10.1111","volume":"116","author":[{"given":"Florian","family":"Beuer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bastian","family":"Steff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Naumann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John A.","family":"Sorensen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,7,9]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1038\/BDJ.2007.534"},{"key":"e_1_2_6_3_2","first-page":"577","article-title":"Precision of a CAD\/CAM technique for the production of zirconium dioxide copings","volume":"17","author":"Coli P","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2004.02.004"},{"key":"e_1_2_6_5_2","first-page":"508","article-title":"Guidelines for success with zirconia ceramics: the changing standards","volume":"17","author":"Devaud V","year":"2005","journal-title":"Pract Proced Aesthet Dent"},{"key":"e_1_2_6_6_2","first-page":"455","article-title":"Retention of selected core materials to zirconia posts","volume":"27","author":"Edelhoff D","year":"2002","journal-title":"Oper Dent"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.11607\/prd.00.0599"},{"key":"e_1_2_6_8_2","first-page":"249","article-title":"All\u2010ceramic full\u2010coverage restorations: concepts and guidelines for material selection","volume":"17","author":"Raigrodski AJ","year":"2005","journal-title":"Pract Proced Aesthet Dent"},{"key":"e_1_2_6_9_2","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1080\/19424396.1998.12221650","article-title":"IPS Empress crown system: three\u2010year clinical trial results","volume":"26","author":"Sorensen JA","year":"1998","journal-title":"J Calif Dent Assoc"},{"key":"e_1_2_6_10_2","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1080\/19424396.1998.12221659","article-title":"In\u2010Ceram fixed partial dentures: three\u2010year clinical trial results","volume":"26","author":"Sorensen JA","year":"1998","journal-title":"J Calif Dent Assoc"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2003.08.007"},{"key":"e_1_2_6_12_2","first-page":"25","article-title":"Status of current CAD\/CAM technology in dental medicine","volume":"7","author":"Tinschert J","year":"2004","journal-title":"Int J Comput Dent"},{"key":"e_1_2_6_13_2","first-page":"231","article-title":"Fracture resistance of lithium disilicate\u2010, alumina\u2010, and zirconia\u2010based three\u2010unit fixed partial dentures: a laboratory study","volume":"14","author":"Tinschert J","year":"2001","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2005.01604.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8240.2002.tb00518.x"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8240.2002.tb00527.x"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-5712(00)00030-0"},{"key":"e_1_2_6_18_2","first-page":"150","article-title":"A long\u2010term retrospective and clinical follow\u2010up study of In\u2010Ceram Alumina FPDs","volume":"16","author":"Olsson KG","year":"2003","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_19_2","first-page":"379","article-title":"Five\u2010year evaluation of posterior all\u2010ceramic three\u2010unit (In\u2010Ceram) FPDs","volume":"14","author":"Vult von Steyern P","year":"2001","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2004.11.012"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0722.2007.00429.x"},{"key":"e_1_2_6_22_2","first-page":"731","article-title":"Fracture strength of artificially aged 3\u2010unit adhesive fixed partial dentures made of fiber\u2010reinforced composites and ceramics: an in vitro study","volume":"37","author":"Kolbeck C","year":"2006","journal-title":"Quintessence Int"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016350500331120"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2006.03.003"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2005.04.024"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2005.04.040"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.1994.tb00144.x"},{"key":"e_1_2_6_28_2","doi-asserted-by":"crossref","first-page":"54","DOI":"10.5005\/jcdp-6-4-54","article-title":"Load\u2010to\u2010fracture value of different all\u2010ceramic crown systems","volume":"6","author":"Snyder MD","year":"2005","journal-title":"J Contemp Dent Pract"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2004.07.013"},{"key":"e_1_2_6_30_2","first-page":"462","article-title":"The fracture resistance of all\u2010ceramic crowns on supporting structures with different elastic moduli","volume":"6","author":"Scherrer SS","year":"1993","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2004.01437.x"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1007\/s007840050041"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1177\/154405910308200317"},{"key":"e_1_2_6_34_2","first-page":"89","article-title":"Three\u2010dimensional finite element analyses of all\u2010ceramic posterior fixed partial dentures with different designs","volume":"20","author":"Molin M","year":"2007","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_35_2","doi-asserted-by":"publisher","DOI":"10.1177\/00220345950740060301"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2006.02.002"},{"key":"e_1_2_6_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2004.03.001"},{"key":"e_1_2_6_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2005.07.009"},{"key":"e_1_2_6_39_2","first-page":"183","article-title":"Flexural strength of In\u2010Ceram alumina and In\u2010Ceram zirconia core materials","volume":"15","author":"Chong KH","year":"2002","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0109-5641(00)00080-4"},{"key":"e_1_2_6_41_2","first-page":"487","article-title":"Probability of failure of veneered glass fiber\u2010reinforced composites and glass\u2010infiltrated alumina with or without zirconia reinforcement","volume":"16","author":"Chong KH","year":"2003","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(89)90075-9"},{"key":"e_1_2_6_43_2","first-page":"430","article-title":"Fracture surface analysis of dental ceramics: clinically failed restorations","volume":"3","author":"Kelly JR","year":"1990","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_44_2","first-page":"55","article-title":"Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen. [Maximal biteforce, a factor in designing dental constructions]","volume":"31","author":"K\u00f6rber K","year":"1983","journal-title":"Dent Lab"},{"key":"e_1_2_6_45_2","first-page":"35","article-title":"Three\u2010year clinical evaluation of In\u2010Ceram Zirconia posterior FPDs","volume":"17","author":"Suarez MJ","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2006.08.010"},{"key":"e_1_2_6_47_2","first-page":"685","article-title":"Prospective clinical study of zirconia posterior fixed partial dentures: 3\u2010year follow\u2010up","volume":"37","author":"Sailer I","year":"2006","journal-title":"Quintessence Int"}],"container-title":["European Journal of Oral Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0722.2008.00551.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0722.2008.00551.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T00:23:24Z","timestamp":1696983804000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0722.2008.00551.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,7,9]]},"references-count":46,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2008,8]]}},"alternative-id":["10.1111\/j.1600-0722.2008.00551.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0722.2008.00551.x","archive":["Portico"],"relation":{},"ISSN":["0909-8836","1600-0722"],"issn-type":[{"value":"0909-8836","type":"print"},{"value":"1600-0722","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,7,9]]},"assertion":[{"value":"2008-07-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}