{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T17:01:03Z","timestamp":1751734863272},"reference-count":15,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2006,4,27]],"date-time":"2006-04-27T00:00:00Z","timestamp":1146096000000},"content-version":"vor","delay-in-days":3495,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dental Traumatology"],"published-print":{"date-parts":[[1996,10]]},"abstract":"<jats:p><jats:bold>Abstract<\/jats:bold> Twenty samples of each size designation of finger spreaders and accessory gutta\u2010percha cones were randomly selected from a proprietary standardized system currently used for lateral condensation procedures. Their diameters were measured with a calliper and their morphological variations at the areas of their apical thirds were analized with the scanning electron microscope. Results of the measurements indicated that there were high degrees of variation between all spreaders and their corresponding accessory gutta\u2010pereha cones (p&lt;0.001). SEM examination showed the presence of many morphologic irregularities and lack of uniformity between spreaders and cones of the same size. Our results emphasize the need for more precise criteria to fulfill the requirements of standardization by the manufacturer to provide an accurate method for root canal obturation.<\/jats:p>","DOI":"10.1111\/j.1600-9657.1996.tb00521.x","type":"journal-article","created":{"date-parts":[[2006,4,28]],"date-time":"2006-04-28T17:45:38Z","timestamp":1146246338000},"page":"237-239","source":"Crossref","is-referenced-by-count":4,"title":["Compatibility between standardized endodontic finger spreaders and accessory gutta\u2010percha cones"],"prefix":"10.1111","volume":"12","author":[{"given":"Osvaldo","family":"Zmener","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rodoflo","family":"Hilu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rosa","family":"Scavo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,4,27]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/S0011-8532(22)03244-X","article-title":"Filling root canals in three dimensions","author":"Schilder H.","year":"1967","journal-title":"Dent Clin North Am"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(77)80091-5"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(81)80214-2"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(85)80122-9"},{"key":"e_1_2_1_6_2","first-page":"312","article-title":"Opinions and practices of American Endodontic Diplomates","volume":"44","author":"Taintor JF","year":"1978","journal-title":"Dent J"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1959.0048"},{"key":"e_1_2_1_8_2","first-page":"341","article-title":"Gutta\u2010percha versus silver points in the practice of endodontics","volume":"31","author":"Luks S.","year":"1965","journal-title":"NY State Dent J"},{"key":"e_1_2_1_9_2","first-page":"pp 239","volume-title":"Eudodontics","author":"Ingle JI","year":"1976"},{"key":"e_1_2_1_10_2","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/S0011-8532(22)02207-8","article-title":"Advanced techniques for intracanal preparation and filling in routine endodountic therapy","volume":"28","author":"Taylor GN.","year":"1984","journal-title":"Dent Clin North Am"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(88)80130-4"},{"key":"e_1_2_1_12_2","first-page":"27","article-title":"Modern endodontic therapy","author":"Ingle JL","year":"1985","journal-title":"Philadelphia Lea & Fabiger"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0030-4220(79)90153-1"},{"key":"e_1_2_1_14_2","unstructured":"American National Standards Institute\/American Dental Association.Specification No 57 for endodontic filling materials 1984."},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(06)81625-0"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-9657.1991.tb00177.x"}],"container-title":["Dental Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-9657.1996.tb00521.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-9657.1996.tb00521.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,26]],"date-time":"2023-10-26T16:46:27Z","timestamp":1698338787000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-9657.1996.tb00521.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,10]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1996,10]]}},"alternative-id":["10.1111\/j.1600-9657.1996.tb00521.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-9657.1996.tb00521.x","archive":["Portico"],"relation":{},"ISSN":["1600-4469","1600-9657"],"issn-type":[{"value":"1600-4469","type":"print"},{"value":"1600-9657","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,10]]}}}