{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T10:46:02Z","timestamp":1789987562681,"version":"4.0.1"},"reference-count":40,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,1,15]],"date-time":"2008-01-15T00:00:00Z","timestamp":1200355200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Dental Hygiene"],"published-print":{"date-parts":[[2008,2]]},"abstract":"<jats:p><jats:bold>Abstract:\u2002<\/jats:bold><jats:bold> Objective:\u00a0<\/jats:bold> To evaluate by means of Petrifilm\u2122 system (3M, St Paul, MN, USA) the level of bacterial contamination in water from old and new dental units (air\u2013water syringes and high\u2010speed turbines) before and after flushing water through waterlines. The old dental units had been used for 13\u2003years and the new dental units for 1\u2003year. A fast method named Petrifilm\u2122 AC (3M) was employed to evaluate the level of water contamination with total aerobic bacteria and Petrifilm\u2122 EC for <jats:italic>Escherichia coli<\/jats:italic> and coliforms.<\/jats:p><jats:p><jats:bold>Methods:\u00a0<\/jats:bold> Dental unit water were collected before and after flushing of 4 (air\u2013water syringes) and 2\u2003min (high\u2010speed turbines) from 24 old and new dental units. Thereafter, samples were diluted, inoculated onto Petrifilm\u2122 plates and incubated.<\/jats:p><jats:p><jats:bold>Results:\u00a0<\/jats:bold> The filtered tap water that filled up dental unit reservoirs showed a low level of bacterial contamination (4 and 15\u2003CFU\u2003ml<jats:sup>\u22121<\/jats:sup>). However, all water samples from old and new dental units were highly contaminated. The flushing of dental unit waterlines reduced the bacterial count in all dental unit water, but the reduction was better in water from new dental units than from old dental units. <jats:italic>E. coli<\/jats:italic> and coliforms were not detected in any water samples analysed.<\/jats:p><jats:p><jats:bold>Conclusion:\u00a0<\/jats:bold> Flushing water is a simple measure that should do part of dental routine, because it was able to reduce the level of total aerobic bacteria in water from old and new dental units.<\/jats:p>","DOI":"10.1111\/j.1601-5037.2007.00278.x","type":"journal-article","created":{"date-parts":[[2010,8,4]],"date-time":"2010-08-04T10:37:02Z","timestamp":1280918222000},"page":"56-62","source":"Crossref","is-referenced-by-count":9,"title":["Dental unit water: bacterial decontamination of old and new dental units by flushing water"],"prefix":"10.1111","volume":"6","author":[{"given":"E","family":"Watanabe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"AM","family":"Agostinho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W","family":"Matsumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"IY","family":"Ito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,1,15]]},"reference":[{"key":"e_1_2_5_2_2","first-page":"277","volume-title":"Infection Control and Management of Hazardous Materials for the Dental Team","author":"Miller CH","year":"2005"},{"key":"e_1_2_5_3_2","first-page":"621","article-title":"Dental unit water contamination level assessment","volume":"80","author":"Watanabe E","year":"2001","journal-title":"J Dent Res"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1590\/S0103-64402003000100010"},{"key":"e_1_2_5_5_2","unstructured":"AgostinhoAM.Biocides in disinfection of dental unit waterlines: chemical microbiol and by SEM evaluation.PhD Thesis (in Dentistry). Brazil Faculdade de Odontologia de Ribeir\u00e3o Preto Universidade de S\u00e3o Paulo Ribeir\u00e3o Preto 2004 113."},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0722.2004.00151.x"},{"key":"e_1_2_5_7_2","first-page":"87","article-title":"Effects of delayed microbial analysis of dental unit water line specimens","volume":"18","author":"Palenik CJ","year":"2005","journal-title":"Am J Dent"},{"key":"e_1_2_5_8_2","first-page":"413","article-title":"The incidence and control of bacterial infection in dental spray reservoirs","volume":"115","author":"Blake GC","year":"1963","journal-title":"Br Dent J"},{"key":"e_1_2_5_9_2","first-page":"177","article-title":"Microbial aggregate contamination of water lines in dental equipment and its control","volume":"85","author":"Kelstrup J","year":"1977","journal-title":"Acta Pathol Microbiol Scand"},{"key":"e_1_2_5_10_2","first-page":"22","article-title":"Doctor, would you drink water from your dental unit?","volume":"61","author":"Prevost AP","year":"1995","journal-title":"N Y State Dent J"},{"key":"e_1_2_5_11_2","first-page":"389","volume-title":"40 CFR, Chapter I, Subchapter D, Part 124 and 141\u2013148 (July 1, 2002) \u2013 Primary National Drinking Water Regulations","author":"US Environmental Protection Agency","year":"2002"},{"key":"e_1_2_5_12_2","first-page":"9","volume-title":"Standard Methods for the Examination of Water and Wastewater","author":"American Pubic Health Association, American Water Works Association","year":"1999"},{"key":"e_1_2_5_13_2","volume-title":"Estabelece os procedimentos e responsabilidades relativos ao controle e vigil\u00e2ncia da qualidade da \u00e1gua para consumo humano e seu padr\u00e3o de potabilidade, e d\u00e1 outras provid\u00eancias","author":"Brasil. Minist\u00e9rio da Sa\u00fade. Portaria no. 518 de 25 de mar\u00e7o de 2004","year":"2004"},{"key":"e_1_2_5_14_2","first-page":"11","volume-title":"VII Congresso nazionale del \u2018collegio dei docenti di odontoiatria\u2019. Proceedings from a Symposium in Rome, Italy","author":"Dolci G","year":"2000"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1875-595X.1998.tb00697.x"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0011-8532(03)00019-3"},{"key":"e_1_2_5_17_2","first-page":"237","article-title":"Dental waterlines and biofilm\u2010searching for solutions","volume":"23","author":"Mills SE","year":"2002","journal-title":"Compend Contin Educ Dent"},{"key":"e_1_2_5_18_2","doi-asserted-by":"publisher","DOI":"10.1128\/CMR.15.2.167-193.2002"},{"key":"e_1_2_5_19_2","first-page":"5","volume-title":"Dental Plaque Revisited: Oral Biofilms in Health and Disease","author":"Costerton JW","year":"1999"},{"key":"e_1_2_5_20_2","first-page":"1","article-title":"Recommended infection\u2010control practices for dentistry","volume":"28","author":"CDC \u2013 Centers for Disease Control and Prevention","year":"1993","journal-title":"Morb Mortal Wkly Rep"},{"key":"e_1_2_5_21_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1996.0280"},{"key":"e_1_2_5_22_2","first-page":"1653","article-title":"Dental unit waterlines: approaching the year 2000","volume":"130","author":"ADA Council on Scientific Affairs","year":"1999","journal-title":"J Am Dent Assoc"},{"key":"e_1_2_5_23_2","first-page":"9","article-title":"Reduction of CFUs in high\u2010speed handpiece water lines over time","volume":"12","author":"Scheid RC","year":"1990","journal-title":"Clin Prev Dent"},{"key":"e_1_2_5_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0300-5712(91)90075-A"},{"key":"e_1_2_5_25_2","first-page":"262","article-title":"An evaluation of sampling and laboratory procedures for determination of heterotrophic plate counts in dental unit waterlines","volume":"66","author":"Noce L","year":"2000","journal-title":"J Can Dent Assoc"},{"key":"e_1_2_5_26_2","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2001.72.3.393"},{"key":"e_1_2_5_27_2","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2001.72.3.401"},{"key":"e_1_2_5_28_2","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1002\/j.0022-0337.2002.66.4.tb03534.x","article-title":"How does time\u2010dependent dental unit waterline flushing affect planktonic bacteria levels?","volume":"66","author":"Cobb CM","year":"2002","journal-title":"J Dent Educ"},{"key":"e_1_2_5_29_2","volume-title":"Nonparametric Methods for the Behavioral Sciences","author":"Siegel S","year":"1956"},{"key":"e_1_2_5_30_2","first-page":"41","article-title":"A pilot study of 2 methods for control of dental unit biofilms","volume":"31","author":"Kim PJ","year":"2000","journal-title":"Quintessence Int"},{"key":"e_1_2_5_31_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.4801651"},{"key":"e_1_2_5_32_2","first-page":"755","article-title":"Clearance of biofilms from dental unit waterlines through the use of hydroperoxide ion\u2010phase transfer catalysts","volume":"32","author":"Shepherd PA","year":"2001","journal-title":"Quintessence Int"},{"key":"e_1_2_5_33_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.4801635"},{"key":"e_1_2_5_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1875-595X.2002.tb00626.x"},{"key":"e_1_2_5_35_2","first-page":"256","article-title":"Effect of in\u2010line bacteriological filters on numbers of heterotrophic bacteria in water emitted from non\u2010autoclavable dental air\u2013water syringes","volume":"12","author":"Mayo JA","year":"1999","journal-title":"Am J Dent"},{"key":"e_1_2_5_36_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1994.0164"},{"key":"e_1_2_5_37_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.5005\/jcdp-3-3-1","article-title":"Reducing bacterial counts in dental unit waterlines: tap waters vs. distilled water","volume":"3","author":"Kettering JD","year":"2002","journal-title":"J Contemp Dent Pract"},{"key":"e_1_2_5_38_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.2002.0361"},{"key":"e_1_2_5_39_2","doi-asserted-by":"publisher","DOI":"10.1177\/00220345710500063601"},{"key":"e_1_2_5_40_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1993.0205"},{"key":"e_1_2_5_41_2","first-page":"528","article-title":"Microbial contamination of dental unit water lines: short and long\u2010term effects of flushing","volume":"45","author":"Santiago JI","year":"1994","journal-title":"Gen Dent"}],"container-title":["International Journal of Dental Hygiene"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1601-5037.2007.00278.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1601-5037.2007.00278.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T19:46:32Z","timestamp":1697053592000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1601-5037.2007.00278.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,1,15]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,2]]}},"alternative-id":["10.1111\/j.1601-5037.2007.00278.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1601-5037.2007.00278.x","archive":["Portico"],"relation":{},"ISSN":["1601-5029","1601-5037"],"issn-type":[{"value":"1601-5029","type":"print"},{"value":"1601-5037","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,1,15]]}}}