{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T06:44:36Z","timestamp":1697006676341},"reference-count":24,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2007,9,21]],"date-time":"2007-09-21T00:00:00Z","timestamp":1190332800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Deutsche Derma Gesell"],"published-print":{"date-parts":[[2007,12]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p> <jats:italic>Background:<\/jats:italic> Adequate peripheral venous access is crucial for successful extracorporeal photopheresis (ECP). As this approach is not always feasible in older patients and patients with graft\u2010versus\u2010host disease, central venous catheters play an increasing role in providing long\u2010term vascular access for ECP.However, not all catheters are able to deliver the minimum flow rate of 7 ml\/min for ECP.<\/jats:p><jats:p> <jats:italic>Patients and Methods:<\/jats:italic> Eight different permanent subcutaneous right atrial catheters were connected in vitro to the UVAR<jats:sup>\u00ae<\/jats:sup>\u2010XTS\u2122 photopheresis system and median flow rates were determined. In addition, in vivo flow rates of patients who received ECP, using either peripheral or central venous access, were determined.<\/jats:p><jats:p> <jats:italic>Results:<\/jats:italic> Hemodialysis catheters with an internal diameter of 2.0 or 1.5 \u00d7 3.5 mm and a length up to 48 cm provided in vitro flow rates of 27\u201328 ml\/min, almost identical to a peripheral access needle. Central venous catheters with a length of over 90 cm reached flow rates below 7 ml\/min and are impractical for ECP. The analysis of 308 ECP collection cycles with peripheral vascular access revealed an average flow rate of 31.5 \u00b1 6.4 ml\/min. Only permanent subcutaneous right atrial catheters made for hemodialysis provided similar flow rates (Quinton PermCath Dual Lumen) (33.7 \u00b1 4.7 ml\/min, n = 198).<\/jats:p><jats:p> <jats:italic>Conclusions:<\/jats:italic> Permanent subcutaneous hemodialysis catheters with a length of maximally 48 cm achieve optimal flow rates for ECP. They represent therefore the central venous access of choice in patients with inadequate peripheral vascular access.<\/jats:p>","DOI":"10.1111\/j.1610-0387.2007.06524.x","type":"journal-article","created":{"date-parts":[[2007,9,22]],"date-time":"2007-09-22T07:11:09Z","timestamp":1190445069000},"page":"1112-1118","source":"Crossref","is-referenced-by-count":4,"title":["Extracorporeal photopheresis with permanent subcutaneous right atrial catheters"],"prefix":"10.1111","volume":"5","author":[{"given":"Hartmut","family":"St\u00e4nder","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Neugebauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan W.","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas A.","family":"Luger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meinhard","family":"Schiller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,9,28]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1001\/archderm.137.10.1309"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/archderm.1992.01680130051005"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaad.2005.11.1091"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2036.2001.01054.x"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/adc.85.2.149"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199812103392404"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2133.2005.06857.x"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/1523-1747.ep12329711"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-1097.1997.tb01895.x"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.4049\/jimmunol.174.10.5968"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdermsci.2006.05.004"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2004-813258"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bmt.1704851"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1473-0502(02)00102-7"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2003-36895"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-139x.2001.00109.x"},{"key":"e_1_2_7_18_2","first-page":"907","article-title":"Pr\u00e4vention Gef\u00e4\u00dfkatheter\u2010assoziierter Infektionen","volume":"45","author":"Empfehlung der Kommission f\u00fcr Krankenhaushygiene und der Infektionspr\u00e4vention beim Robert Koch\u2010Institut (RKI)","year":"2002","journal-title":"Bundesgesundheitsbl Gesundheitsforsch Besundheitsschutz"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1492-7535.2003.00024.x"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1523-1755.2001.00947.x"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.6004\/jnccn.2006.0074"},{"key":"e_1_2_7_22_2","first-page":"88","article-title":"Venenkatheter\u2010assoziierte Infektionen: Pr\u00e4ventionspotenziale werden oft noch nicht ausgesch\u00f6pft","volume":"58","author":"Panknin HT","year":"2005","journal-title":"Pflege Z"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MAT.0000093969.27009.AB"},{"key":"e_1_2_7_24_2","doi-asserted-by":"crossref","unstructured":"ShahCB MittelmanMW CostertonJW ParenteauS PelakM ArsenaultR MermelLA.Antimicrobial activity of a novel catheter lock solution.Antimicrob Agents Chemother2002;46:1674\u20101679.","DOI":"10.1128\/AAC.46.6.1674-1679.2002"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.ackd.2006.04.003"}],"container-title":["JDDG: Journal der Deutschen Dermatologischen Gesellschaft"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1610-0387.2007.06524.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1610-0387.2007.06524.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T22:58:19Z","timestamp":1696978699000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1610-0387.2007.06524.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,9,28]]},"references-count":24,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2007,12]]}},"alternative-id":["10.1111\/j.1610-0387.2007.06524.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1610-0387.2007.06524.x","archive":["Portico"],"relation":{},"ISSN":["1610-0379","1610-0387"],"issn-type":[{"value":"1610-0379","type":"print"},{"value":"1610-0387","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,9,28]]}}}