{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T04:26:34Z","timestamp":1776399994856,"version":"3.51.2"},"reference-count":11,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2008,11,18]],"date-time":"2008-11-18T00:00:00Z","timestamp":1226966400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Paediatrica"],"published-print":{"date-parts":[[2009,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Aim: To quantify the number of chest and abdominal radiograms performed in surviving singleton extremely low birth weight (ELBW) infants in order to examine whether changes in imaging application occurred during the last 21 years (1987\u20132007).<\/jats:p><jats:p>Methods: Clinical and radiological data of 225 out of 229 surviving infants were obtained and associations with time and clinical variables were evaluated.<\/jats:p><jats:p>Results: The number of chest X\u2010Rays performed per infant was 10.3 \u00b1 11.1 (mean \u00b1 SD), median = 7; range = 0\u201377 and the number of abdominal radiograms was 5.6 \u00b1 7.1, median = 3; range = 0\u201361. The number of chest and abdominal X\u2010Rays performed per patient during 1987\u20131996 was very similar to that of 1997\u20132007, and no appreciable change of trend was observed along the years. There were negative and statistically significant correlations between the gestational age and the number of radiograms performed per patient (chest X\u2010Rays: r =\u20130.402; p &lt; 0.001, abdominal X\u2010Rays: r =\u20130.182; p = 0.006). Controlling for gestational age, reduced numbers of radiograms per patient (abdominal: b =\u20131.20, p = 0.235; chest: b =\u20133.08, p = 0.035) were demonstrated in the second period.<\/jats:p><jats:p>Patients with complicated clinical course were exposed to significantly more radiograms.<\/jats:p><jats:p>Conclusion: Controlling for gestational age, a reduced number of exposures to chest radiograms was demonstrated during 1997\u20132007 compared with 1987\u20131996. Measures to reduce radiation, especially in complicated cases, are advocated.<\/jats:p>","DOI":"10.1111\/j.1651-2227.2008.01087.x","type":"journal-article","created":{"date-parts":[[2008,12,3]],"date-time":"2008-12-03T19:28:10Z","timestamp":1228332490000},"page":"266-269","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Exposure of extremely low birth weight infants to diagnostic X\u2010Rays: a longitudinal study"],"prefix":"10.1111","volume":"98","author":[{"given":"Ilan","family":"Arad","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Natalia","family":"Simanovsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rony","family":"Braunstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,1,12]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1542\/peds.97.3.369","article-title":"Radiation exposure from diagnostic radiographs in extremely low birth weight infants","volume":"97","author":"Wilson\u2010Costello D","year":"1996","journal-title":"Pediatrics"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2005-0817"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/fn.78.3.F227"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/fn.88.3.F237"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.328.7430.19"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0221-0363(05)81334-4"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1080\/02841859809172217"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.rpd.a006127"},{"key":"e_1_2_6_10_2","volume-title":"Radiation exposure of the UK population\u20131993 review","author":"Hughes JS"},{"key":"e_1_2_6_11_2","volume-title":"Recommendations of the ICRP","author":"International Commission on Radiation Protection","year":"1990"},{"key":"e_1_2_6_12_2","first-page":"1555","article-title":"Reduction of patient exposure by the use of digital luminescence radiography","volume":"80","author":"Seifert H","year":"1999","journal-title":"J Radiol"}],"container-title":["Acta Paediatrica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1651-2227.2008.01087.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1651-2227.2008.01087.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T18:45:24Z","timestamp":1697395524000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1651-2227.2008.01087.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,1,12]]},"references-count":11,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2009,2]]}},"alternative-id":["10.1111\/j.1651-2227.2008.01087.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1651-2227.2008.01087.x","archive":["Portico"],"relation":{},"ISSN":["0803-5253","1651-2227"],"issn-type":[{"value":"0803-5253","type":"print"},{"value":"1651-2227","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,1,12]]},"assertion":[{"value":"2009-01-12","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}