{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T03:43:03Z","timestamp":1775274183031,"version":"3.50.1"},"reference-count":30,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2009,9,17]],"date-time":"2009-09-17T00:00:00Z","timestamp":1253145600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Paediatrica"],"published-print":{"date-parts":[[2009,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p><jats:bold>Aim:\u2002<\/jats:bold> To evaluate the performance of the Konica Minolta\/Air\u2010Shields<jats:sup>\u00ae<\/jats:sup> JM\u2010103 jaundice meter on the basis of infant skin tone during the early neonatal period.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Infants were prospectively categorized into light, medium and dark skin tone groups relative to two reference colours. Transcutaneous bilirubin readings were taken at predetermined intervals through the early neonatal period on a convenience sample of 938 healthy infants \u226537\u2003weeks gestation. Serum bilirubin measurements were drawn routinely with metabolic studies and repeated in the presence of an elevated transcutaneous reading or clinically significant jaundice.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Multivariate linear regression analysis showed a significant impact on serum and transcutaneous bilirubin agreement by skin tone. Highest precision and lowest bias were observed for medium skin toned infants. Greater disagreement between serum and transcutaneous measurements was noted at serum bilirubin concentrations &gt;200\u2003\u03bcmol\/L. Insufficient numbers of dark skin toned infants were enroled to evaluate fully the performance of the jaundice meter for this group.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> The JM\u2010103 jaundice meter displayed good correlation with serum bilirubin concentrations in light and medium skin tone infants, although it showed a tendency to under\u2010read in the lighter skin tone group and to over\u2010read in the darker skin tone group. The device shows excellent performance characteristics for use as a screening device.<\/jats:p>","DOI":"10.1111\/j.1651-2227.2009.01497.x","type":"journal-article","created":{"date-parts":[[2009,9,17]],"date-time":"2009-09-17T14:01:31Z","timestamp":1253196091000},"page":"1909-1915","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":53,"title":["Impact of skin tone on the performance of a transcutaneous jaundice meter"],"prefix":"10.1111","volume":"98","author":[{"given":"Stephen","family":"Wainer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yacov","family":"Rabi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seema M.","family":"Parmar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Donna","family":"Allegro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martha","family":"Lyon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,11,2]]},"reference":[{"key":"e_1_2_7_2_2","first-page":"958","article-title":"Hyperbilirubinemia in the newborn","volume":"61","author":"Davidson LT","year":"1941","journal-title":"Am J Dis Child"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/archpedi.154.4.391"},{"key":"e_1_2_7_4_2","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1542\/peds.94.4.558","article-title":"Practice parameter: management of hyperbilirubinemia in the healthy term newborn","volume":"94","author":"American Academy of Pediatrics, Provisional Committee for Quality Improvement and Subcommittee on Hyperbilirubinemia","year":"1994","journal-title":"Pediatrics"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.114.1.297"},{"key":"e_1_2_7_6_2","first-page":"1B","article-title":"Canadian Paediatric Society","volume":"12","author":"Fetus and Newborn Committee","year":"2007","journal-title":"Paediatr Child Health"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1373\/clinchem.2004.037804"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1136\/fn.86.3.F190"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2005-0590"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1093\/pch\/11.2.75"},{"key":"e_1_2_7_11_2","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1542\/peds.69.1.107","article-title":"Evaluation of the Minolta Bilirubin Meter as a screening device in White and Black infants","volume":"69","author":"Hannemann RE","year":"1982","journal-title":"Pediatrics"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.jp.7210592"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.110.1.61"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.106.2.e17"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.113.6.1628"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/adc.2005.090217"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2005-1203"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.113.6.1636"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.107.6.1264"},{"key":"e_1_2_7_20_2","first-page":"93","article-title":"Transcutaneous bilirubinometry in Black infants: improved reliability after correction for the background signal","volume":"4","author":"Wainer S","year":"1989","journal-title":"Pediatr Rev Commun"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1040751"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.1990.tb11406.x"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.1992.tb12281.x"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.jp.7211333"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1515\/JPM.2003.012"},{"key":"e_1_2_7_26_2","first-page":"1533","article-title":"Comparison of two transcutaneous bilirubinometers \u2013 Minolta AirShields Jaundice Meter JM103 and Spectrx BiliCheck \u2013 in Thai neonates","volume":"36","author":"Sanpavat S","year":"2005","journal-title":"Southeast Asian J Trop Med Public Health"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.113.4.775"},{"key":"e_1_2_7_28_2","unstructured":"Jaundice Meter JM\u2010103 Instruction Manual.Konica Minolta Inc. Osaka Japan 2002."},{"key":"e_1_2_7_29_2","unstructured":"Mary Kay Inc. Dallas TX. Available athttp:\/\/www.marykay.com\/color\/foundations\/fullcoveragefoundation\/default.aspx. (accessed August 26 2009)."},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.2307\/2685368"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.2307\/2532051"}],"container-title":["Acta Paediatrica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1651-2227.2009.01497.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1651-2227.2009.01497.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T01:10:22Z","timestamp":1697418622000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1651-2227.2009.01497.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,11,2]]},"references-count":30,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["10.1111\/j.1651-2227.2009.01497.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1651-2227.2009.01497.x","archive":["Portico"],"relation":{},"ISSN":["0803-5253","1651-2227"],"issn-type":[{"value":"0803-5253","type":"print"},{"value":"1651-2227","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,11,2]]},"assertion":[{"value":"2009-11-02","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}