{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T19:20:47Z","timestamp":1788549647700,"version":"build-2803163510"},"reference-count":25,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2007,4,10]],"date-time":"2007-04-10T00:00:00Z","timestamp":1176163200000},"content-version":"vor","delay-in-days":2474,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2000,7]]},"abstract":"<jats:sec><jats:title>ABSTRACT<\/jats:title><\/jats:sec><jats:sec><jats:title>Purpose:<\/jats:title><jats:p>To study the bone response around implants placed in tibia of rabbits that supported misfitting superstructures secured with different degrees of preload.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods:<\/jats:title><jats:p>Twelve rabbits were provided with two terminal 10\u2010mm and one intermediate 7\u2010mm\u2010long implant in each tibia. After an integration time of about 9 weeks, nine of the animals received one control framework each (n = 9), designed with good fit to all three implants. In the other tibia of these animals, and in both tibias in the remaining three rabbits, test frameworks (n = 15) were connected with a vertical misfit of about 1 mm to the intermediate implant. The intermediate set screws were tightened with a torque ranging from 15 Ncm to 26 Ncm in the different test frameworks. The fascia and skin was then sutured back over the implants. After a loading period of 2 to 3 weeks, the animals were sacrificed, and histomorphometric measurements were made and correlated to the different levels of preload of the central implant.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p>The mean bone\u2010to\u2010metal contact for the three best consecutive threads of the central implant was 40% for both test and control sites (<jats:italic>p<\/jats:italic> &gt; .05). Compared to the other regions of the implant thread, less bone\u2010to\u2010metal contact was found at the tip of the test implant threads in the low preload group (<jats:italic>p<\/jats:italic> &lt; .05). However, the same relation was not observed in the high preload group. A significant correlation was observed between increasing degree of preload in the central screw joint and increasing bone\u2010to\u2010metal contact, most obviously noticed at the tip of the implant thread (<jats:italic>p<\/jats:italic> &lt; .01).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions:<\/jats:title><jats:p>Misfit stress levels of clinical magnitudes do not seem to jeopardize osseointegration per se. On the contrary, clinical levels of preload stress seem to significantly promote bone remodeling at the tip of the implant thread.<\/jats:p><\/jats:sec>","DOI":"10.1111\/j.1708-8208.2000.tb00003.x","type":"journal-article","created":{"date-parts":[[2007,4,10]],"date-time":"2007-04-10T11:03:05Z","timestamp":1176202985000},"page":"129-137","source":"Crossref","is-referenced-by-count":51,"title":["Bone Response to Implant\u2010Supported Frameworks with Differing Degrees of Misfit Preload: In Vivo Study in Rabbits"],"prefix":"10.1111","volume":"2","author":[{"given":"Torsten","family":"Jemt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulf","family":"Lekholm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carina B.","family":"Johansson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,4,10]]},"reference":[{"key":"e_1_2_1_2_2","volume-title":"Osseointegrated implants in the treatment of edentulous jaws: experience from a 10\u2010year period","author":"Br\u00e5nemark P\u2010I","year":"1977"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(83)90361-X"},{"key":"e_1_2_1_4_2","first-page":"63","article-title":"Design of superstructures for osseointegrated fixtures: prosthetic reconstructions on osseointegrated implants. Proceedings of the Gothenburg conference September","volume":"28","author":"Klineberg I","year":"1983","journal-title":"Swed Dent J Suppl"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1998.090408.x"},{"key":"e_1_2_1_6_2","first-page":"169","article-title":"Loose gold screws frequently occur in full\u2010arch fixed prostheses supported by osseointegrated implants after 5 years","volume":"9","author":"Kallus T","year":"1994","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_1_7_2","first-page":"620","article-title":"Prosthesis misfit and marginal bone loss in edentulous implant patients","volume":"11","author":"Jemt T","year":"1996","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(96)90008-6"},{"key":"e_1_2_1_9_2","first-page":"211","volume-title":"Tissue\u2010integrated prostheses: osseointegration in clinical dentistry","author":"Adell R","year":"1985"},{"key":"e_1_2_1_10_2","unstructured":"ForsmalmG.F\u00f6rh\u00e5llandet mellan \u00e5tdragningsmoment och f\u00f6rsp\u00e4nningskraft i distansskruvf\u00f6rbandet \u00f8 3 mm. Gothenburg Sweden T94\/00877: Nobel Biocare AB 1994."},{"key":"e_1_2_1_11_2","first-page":"1","volume-title":"Preparations of histological sections. Nordstedt","author":"Donath K.","year":"1988"},{"key":"e_1_2_1_12_2","first-page":"241","volume-title":"Statistics in medicine","author":"Colton T.","year":"1974"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.3109\/02844318009106712"},{"key":"e_1_2_1_14_2","first-page":"282","article-title":"Mechanical response to functional loading around the threads of retromolar endosseous implants utilized for orthodontic anchorage: coordinated histomorphometric and finite element analysis","volume":"14","author":"Chen J","year":"1999","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(84)90003-4"},{"key":"e_1_2_1_16_2","first-page":"270","article-title":"Failures and complications in 391 consecutively inserted fixed prostheses supported by Br\u00e5nemark implants in edentulous jaws. A study of treatment from the time of prosthesis placement to the first annual check\u2010up","volume":"6","author":"Jemt T.","year":"1991","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_1_17_2","unstructured":"TrogenA.Detektering av felaktig passning f\u00f6r k\u00e4kbens\u2010f\u00f6rankrad protetik.MSc thesis Chalmers University of Technology Gothenburg Sweden 1994."},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1996.070107.x"},{"key":"e_1_2_1_19_2","first-page":"511","article-title":"Inaccurate fit of implant superstructures. Part 1: stress generated on the superstructure relative to size of fit discrepancy","volume":"8","author":"Millington N","year":"1995","journal-title":"Int J Prosthodont"},{"key":"e_1_2_1_20_2","first-page":"17","volume-title":"Passive fit of implant supported superstructures: \u201cfiction or reality?\u201d","author":"Patterson EA","year":"1995"},{"key":"e_1_2_1_21_2","first-page":"7","article-title":"Screws and cylinders in the Nobelpharma implant system","volume":"1","author":"J\u00f6rneus L.","year":"1987","journal-title":"Nobelpharma News"},{"key":"e_1_2_1_22_2","first-page":"5","article-title":"Occlusal forces and chewing ability in dentitions with cross\u2010arch bridges","volume":"26","author":"Laurell L.","year":"1985","journal-title":"Swed Dent J Suppl"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.1997.tb00001.x"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.1999.tb00091.x"},{"key":"e_1_2_1_25_2","first-page":"103","article-title":"Influence of bicortical or monocortical anchorage on maxillary implant stability. A 15\u2010year retrospective study of Br\u00e5nemark System implants","volume":"14","author":"Ivanoff C\u2010J","year":"1999","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_1_26_2","unstructured":"EspositoM.On biological failures of osseointegrated oral implants.Odont Dr thesis Gothenburg University Gothenburg Sweden 1999."}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1708-8208.2000.tb00003.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1708-8208.2000.tb00003.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T09:43:36Z","timestamp":1698572616000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1708-8208.2000.tb00003.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,7]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2000,7]]}},"alternative-id":["10.1111\/j.1708-8208.2000.tb00003.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1708-8208.2000.tb00003.x","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,7]]}}}