{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,12]],"date-time":"2025-07-12T01:30:02Z","timestamp":1752283802962},"reference-count":31,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2011,4,26]],"date-time":"2011-04-26T00:00:00Z","timestamp":1303776000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2011,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p><jats:bold>Background:<\/jats:bold> Thin bioceramic coatings have been regarded as potential substitutes for plasma\u2010sprayed hydroxyapatite coatings.<\/jats:p><jats:p><jats:bold>Purpose:<\/jats:bold> This study tested the hypothesis that a thin bioactive ceramic coating deposition on an alumina\u2010blasted\/acid\u2010etched (AB\/AE) surface would positively affect the biomechanical fixation and bone\u2010to\u2010implant contact (BIC) of plateau root form implants.<\/jats:p><jats:p><jats:bold>Materials and Methods:<\/jats:bold> Implants of two different lengths (i.e., 4.5\u2003\u00d7\u200311\u2003mm long, <jats:italic>n<\/jats:italic>\u2003=\u200336) and 4.5\u2003\u00d7\u20036\u2003mm (short, <jats:italic>n<\/jats:italic>\u2003=\u200336) and two different surfaces, that is, control (AB\/AE) and test (AB\/AE\u2003+\u2003300\u2003\u2013\u2003500\u2003nm bioactive ceramic coating), were placed in the proximal tibiae of six beagle dogs. The implants were retrieved for analyses 2 and 4 weeks after placement. The implants in bone specimens were subjected to torque loads until a 10% drop of the maximum torque was recorded. The specimens were evaluated under optical microscopy for bone morphology and percent BIC. Statistical analysis was performed by a generalized linear mixed effects analysis of variance model and statistical significance set at <jats:italic>p<\/jats:italic>\u2003&lt;\u20030.05.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Significantly higher torque\u2010to\u2010interface fracture levels for test surface groups of both lengths when compared to control surfaces were observed. No significant difference in BIC was observed between test and control implants of equal length. Histomorphological analysis showed higher degrees of bone organization between the plateaus of test implant surfaces at both implantation times.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> Because the presence of a thin bioactive ceramic coating on the surface did not affect BIC, but positively affected implant biomechanical fixation, the hypothesis was partially validated.<\/jats:p>","DOI":"10.1111\/j.1708-8208.2009.00186.x","type":"journal-article","created":{"date-parts":[[2009,8,3]],"date-time":"2009-08-03T16:43:47Z","timestamp":1249317827000},"page":"87-94","source":"Crossref","is-referenced-by-count":17,"title":["Thin Bioactive Ceramic\u2010Coated Alumina\u2010Blasted\/Acid\u2010Etched Implant Surface Enhances Biomechanical Fixation of Implants: An Experimental Study in Dogs"],"prefix":"10.1111","volume":"13","author":[{"given":"Rodrigo","family":"Granato","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Marin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jose N.","family":"Gil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung\u2010Kiang","family":"Chuang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas B.","family":"Dodson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcelo","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulo G.","family":"Coelho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,4,26]]},"reference":[{"key":"e_1_2_7_2_2","first-page":"536","article-title":"Oral implant surfaces: Part 1 \u2013 review focusing on topographic and chemical properties of different surfaces and in vivo responses to them","volume":"17","author":"Albrektsson T","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_7_3_2","first-page":"544","article-title":"Oral implant surfaces: Part 2 \u2013 review focusing on clinical knowledge of different surfaces","volume":"17","author":"Albrektsson T","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.07.020"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/154405910408300704"},{"key":"e_1_2_7_6_2","volume-title":"IBAD nanothick bioceramic incorporation on metallic implants for bone healing enhancement. From physico\/chemical characterization to in\u2010vivo performance evaluation","author":"Coelho PG","year":"2005"},{"key":"e_1_2_7_7_2","first-page":"17","volume-title":"Handbook of bioactive ceramics","author":"deGroot KKC","year":"1990"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1997.080601.x"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1563\/0712.1"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2003.11.053"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2006.060181"},{"key":"e_1_2_7_12_2","first-page":"31","article-title":"The effects of ion beam\u2010assisted deposition of hydroxyapatite on the grit\u2010blasted surface of endosseous implants in rabbit tibiae","volume":"20","author":"Park YS","year":"2005","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"e_1_2_7_13_2","first-page":"427","article-title":"Fabrication and characterization of functionally graded nano\u2010micro porous titanium surface by anodizing","volume":"88","author":"Kim HS","year":"2008","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1166\/jnn.2002.116"},{"key":"e_1_2_7_15_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0011-8532(22)02451-X","article-title":"Calcium phosphate coatings for dental implants","volume":"36","author":"Kay J","year":"1992","journal-title":"Dental Clin North Am"},{"key":"e_1_2_7_16_2","first-page":"271","volume-title":"Contemporary implant denstistry","author":"Lemons J","year":"1999"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1590\/S1678-77572005000100018"},{"key":"e_1_2_7_18_2","first-page":"253","volume-title":"5th World Congress of Biomechanics, 2006, Munich, Germany","author":"Coelho PG","year":"2006"},{"key":"e_1_2_7_19_2","first-page":"581","article-title":"Bone response to plasma\u2010sprayed hydroxyapatite and radiofrequency\u2010sputtered calcium phosphate implants in vivo","volume":"17","author":"Ong JL","year":"2002","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_7_20_2","article-title":"Physico\/chemical characterization and in vivo evaluation of nanothickness bioceramic depositions on alumina\u2010blasted\/acid\u2010etched Ti\u20106Al\u20104V implant surfaces","author":"Coelho PG","year":"2008","journal-title":"J Biomed Mater Res A"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0714.1982.tb00172.x"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.3109\/02844316909036699"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453678108991776"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1177\/154405910608500616"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1988.tb38501.x"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00008505-199807040-00010"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200202000-00009"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.02.029"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1590\/S1678-77572005000100018"},{"key":"e_1_2_7_30_2","article-title":"Discrete calcium phosphate nanocrystalline deposition enhances osteoconduction on titanium\u2010based implant surfaces","author":"Mendes VC","year":"2008","journal-title":"J Biomed Mater Res A"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2003.00972.x"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31264"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1708-8208.2009.00186.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1708-8208.2009.00186.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T03:58:25Z","timestamp":1697428705000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1708-8208.2009.00186.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,4,26]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,6]]}},"alternative-id":["10.1111\/j.1708-8208.2009.00186.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1708-8208.2009.00186.x","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,4,26]]}}}