{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T11:08:35Z","timestamp":1791284915040,"version":"4.1.0"},"reference-count":35,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2009,8,6]],"date-time":"2009-08-06T00:00:00Z","timestamp":1249516800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2012,3]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p><jats:bold>Purpose:<\/jats:bold> Panoramic radiography is often used to analyze the anatomical structure of the teeth, jaws, and temporomandibular joints. Cone beam computed tomography (CBCT) imaging allows multiple axial slices of the image to be obtained through these anatomical structures. The aim of this study was to assess CBCT compared with panoramic radiography to verify the presence, location, and dimensions of the mandibular incisive canal.<\/jats:p><jats:p><jats:bold>Materials and Methods:<\/jats:bold> CBCT scan images and panoramic radiographs of 89 subjects were compared for the presence of the mandibular incisive canal, its location, size, and anterior\u2010posterior length. The distance between the incisive canal and the buccal and lingual plate of the alveolar bone, and the distance from the canal to the inferior border of the mandible and the tooth apex were also measured. A paired <jats:italic>t<\/jats:italic>\u2010test was used to calculate any significant difference between the two imaging techniques.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Eighty\u2010three percent of the CBCT scans showed the presence of the incisive canal, as did 11% of the panoramic radiographs. The range of the incisive canal diameter, as seen in the CBCT scans, was from 0.4\u2003\u00d7\u20030.4\u2003mm to 4.6\u2003\u00d7\u20033.2\u2003mm. The mean length of the canal was 7\u2003\u00b1\u20033.8\u2003mm. The distance from the inferior border of the mandible to the canal was 10.2\u2003\u00b1\u20032.4\u2003mm, and the mean distance to the buccal plate was 2.4\u2003mm. The apex\u2013canal distance (in dentate subjects) was 5.3\u2003mm.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> The presence, location, and dimensions of the mandibular incisive canal are better determined by CBCT imaging than by panoramic radiography.<\/jats:p>","DOI":"10.1111\/j.1708-8208.2009.00228.x","type":"journal-article","created":{"date-parts":[[2009,8,6]],"date-time":"2009-08-06T15:39:17Z","timestamp":1249573157000},"page":"67-73","source":"Crossref","is-referenced-by-count":67,"title":["Mandibular Incisive Canal: Cone Beam Computed Tomography"],"prefix":"10.1111","volume":"14","author":[{"given":"Carlos A.","family":"Pires","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nabil F.","family":"Bissada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffery J.","family":"Becker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Kanawati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Landers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,1,24]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-004-0242-2"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(89)90110-8"},{"key":"e_1_2_5_4_2","first-page":"7","article-title":"Radiographic modalities for diagnosis and treatment planning in implant dentistry","volume":"5","author":"Garg AK","year":"1995","journal-title":"Implant Soc"},{"key":"e_1_2_5_5_2","first-page":"428","article-title":"Errors in radiographic assessment of marginal bone height around osseointegrated implants","volume":"98","author":"Sewerin IP","year":"1990","journal-title":"Scand J Dent Res"},{"key":"e_1_2_5_6_2","first-page":"232","article-title":"Considerations in design and fabrication of maxillary implant\u2010supported prostheses","volume":"4","author":"Watson RM","year":"1991","journal-title":"Int J Prosthodont"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-051X.1991.tb00063.x"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.1991.0325"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1067\/moe.2000.106336"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20.1.1884852"},{"key":"e_1_2_5_11_2","first-page":"255","article-title":"Computed tomography in the determination of anatomical landmarks in the perspective of endosseous implant installation","volume":"7","author":"Casselman JW","year":"1988","journal-title":"J Head Neck Pathol"},{"key":"e_1_2_5_12_2","first-page":"137","article-title":"Computed tomography: part 1. Preoperative assessment of the mandible for endosseous implant surgery","volume":"2","author":"Schwarz MS","year":"1987","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_13_2","first-page":"142","article-title":"Computed tomography: part 2. Preoperative assessment of the mandible for endosseous implant surgery","volume":"2","author":"Schwarz MS","year":"1987","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_14_2","first-page":"1","article-title":"Conventional spiral and low\u2010dose computed mandibular tomography for dental implant planning","volume":"138","author":"Ekestubbe A","year":"1991","journal-title":"Swed Dent J Suppl"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1067\/moe.2001.118286"},{"key":"e_1_2_5_16_2","first-page":"455","article-title":"A comparison of the accuracy of periapical panoramic and computerized tomographic radiograph in locating the mandibular canal","volume":"9","author":"Sonick A","year":"1994","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_17_2","volume-title":"Sicher's oral anatomy","author":"DuBrul EL","year":"1980"},{"key":"e_1_2_5_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-4356(97)90043-7"},{"key":"e_1_2_5_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/0266-4356(95)90037-3"},{"key":"e_1_2_5_20_2","first-page":"37","article-title":"Predictable mandibular nerve location: a clinical zone of safety","volume":"7","author":"Misch CE","year":"1990","journal-title":"Int J Oral Implantol"},{"key":"e_1_2_5_21_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.dmfr.4600719"},{"key":"e_1_2_5_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/ca.1080"},{"key":"e_1_2_5_23_2","first-page":"249","article-title":"Radiological examination for location of the mandibular canal: a comparison between panoramic radiography and conventional tomography","volume":"4","author":"Lindh C","year":"1989","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_24_2","first-page":"455","article-title":"A comparison of the accuracy of periapical, panoramic, and computerized tomographic radiographs in locating the mandibular canal","volume":"9","author":"Sonick M","year":"1994","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_25_2","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2006.060197"},{"key":"e_1_2_5_26_2","first-page":"591","article-title":"The intraosseous course of the mandibular incisive nerve in the mandibular symphysis","volume":"21","author":"De Andrade E","year":"2001","journal-title":"Int J Periodontics Restorative Dent"},{"key":"e_1_2_5_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2006.10.015"},{"key":"e_1_2_5_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-000-0157-5"},{"key":"e_1_2_5_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-003-0152-8"},{"key":"e_1_2_5_30_2","first-page":"68","article-title":"Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal regions for prevention of bleeding complications during implant surgery","volume":"16","author":"Tepper G","year":"2001","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_5_31_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-004-0242-2"},{"key":"e_1_2_5_32_2","first-page":"763","article-title":"Diagnostic quality of panoramic views obtained by a newly volumetric digital volume tomography device for maxillofacial imaging","volume":"38","author":"Mischkowski RA","year":"2007","journal-title":"Quintessence Int"},{"key":"e_1_2_5_33_2","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.2004.0179"},{"key":"e_1_2_5_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2004.00991.x"},{"key":"e_1_2_5_35_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.dmfr.4600310"},{"key":"e_1_2_5_36_2","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20.1.1884852"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1708-8208.2009.00228.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1708-8208.2009.00228.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T21:29:12Z","timestamp":1698787752000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1708-8208.2009.00228.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1,24]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,3]]}},"alternative-id":["10.1111\/j.1708-8208.2009.00228.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1708-8208.2009.00228.x","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,1,24]]}}}