{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T15:43:39Z","timestamp":1760888619205},"reference-count":29,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2012,1,17]],"date-time":"2012-01-17T00:00:00Z","timestamp":1326758400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2013,12]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p><jats:bold>Background:<\/jats:bold> During the last decade, high success rates have been reported for implants placed with immediate loading procedures, especially when bone quality and quantity provide good implant stability. In many of these studies, straight\u2010walled implants with moderately rough surfaces were employed. Tapered implants are becoming increasingly more popular due to standardized drilling protocols and reports of high initial primary stability.<\/jats:p><jats:p><jats:bold>Purpose:<\/jats:bold> The aim of the present prospective, single center clinical study was to evaluate surface topographical analysis and the clinical and radiographic outcomes of the NanoTite\u2122 (BIOMET 3i, Palm Beach Gardens, FL, USA) Tapered Implant when used for immediate loading of fixed prostheses and single\u2010tooth restorations.<\/jats:p><jats:p><jats:bold>Materials and Methods:<\/jats:bold> Forty\u2010two patients who needed implant treatment and met admission criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 30\u2003Ncm prior to final seating and an implant stability quotient above 55. A total of 139 NanoTite Tapered implants (112 maxillary and 27 mandibular) were placed by one investigator, and the majority of these implants (<jats:italic>n<\/jats:italic>\u2003=\u200377\/55%) were placed in posterior regions, and in soft bone (<jats:italic>n<\/jats:italic>\u2003=\u200390\/65%). A total of 57 prosthetic constructions were evaluated consisting of 20 single\u2010tooth restorations, 30 fixed partial dentures, and 7 complete, fixed maxillary restorations. Radiographs were taken at baseline and at 12 months of follow\u2010up.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Of the 139 study implants, one implant failure was declared. The overall cumulative survival rate at 1 year is 99.4%. Mean marginal bone resorption is 1.01\u2003mm (SD 0.85) during the first year of function.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> Although limited to the short follow\u2010up, immediate loading of NanoTite Tapered implants seems to be a viable option in implant rehabilitation, when insertion torque of at least 30\u2003Ncm is achieved. Further studies are needed to authenticate the finding of this study.<\/jats:p>","DOI":"10.1111\/j.1708-8208.2011.00437.x","type":"journal-article","created":{"date-parts":[[2012,1,17]],"date-time":"2012-01-17T19:53:19Z","timestamp":1326829999000},"page":"809-818","source":"Crossref","is-referenced-by-count":40,"title":["Immediate Occlusal Loading of NanoTite\u2122 Tapered Implants: A Prospective 1\u2010Year Clinical and Radiographic Study"],"prefix":"10.1111","volume":"15","author":[{"given":"P\u00e4r\u2010Olov","family":"\u00d6stman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ann","family":"Wennerberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annika","family":"Ekestubbe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomas","family":"Albrektsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,1,17]]},"reference":[{"key":"e_1_2_6_2_2","unstructured":"iData Inc.U.S. Market for Dental Implants and Final Abutments 2012 Report. iData Research iData Inc. 2011."},{"key":"e_1_2_6_3_2","unstructured":"iData Inc.European Markets for Dental Implants and Final Abutments 2011. iData Research iData Inc. 2011."},{"issue":"1","key":"e_1_2_6_4_2","first-page":"CD003878","article-title":"Interventions for replacing missing teeth: different times for loading dental implants","author":"Esposito M","year":"2009","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2005.tb00076.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2004.01013.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0757.2007.00244.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2005.04.015"},{"key":"e_1_2_6_9_2","first-page":"77","article-title":"Resonance frequency analysis measurements of implants at placement surgery","volume":"19","author":"\u00d6stman PO","year":"2006","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.5051\/jpis.2010.40.5.239"},{"key":"e_1_2_6_11_2","first-page":"cxxi","article-title":"Nanometer\u2010scale CaP enhances early implant\u2010bone fixation in an animal model","volume":"17","author":"Kenealy JN","year":"2006","journal-title":"Clin Oral Implants Res"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.07.020"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1088\/0957-4484\/18\/24\/245101"},{"key":"e_1_2_6_14_2","first-page":"210","article-title":"Influence of a nanometer\u2010scale surface enhancement on de novo bone formation on titanium implants: a histomorphometric study in human maxillae","volume":"3","author":"Goen\u00e9 RJ","year":"2007","journal-title":"Int J Periodontics Restorative Dent"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2007.060297"},{"key":"e_1_2_6_16_2","first-page":"199","volume-title":"Tissue\u2010integrated prostheses: osseointegration in clinical dentistry","author":"Lekholm U","year":"1985"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2007.00069.x"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2004.tb00027.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00186.x"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2008.00128.x"},{"issue":"8","key":"e_1_2_6_21_2","first-page":"99","article-title":"Influence of the implant cervical topography on the crestal bone resorption and immediate implant survival","volume":"60","author":"Heinemann F","year":"2009","journal-title":"J Physiol Pharmacol"},{"key":"e_1_2_6_22_2","first-page":"63","article-title":"On implant surfaces: a review of current knowledge and opinions","volume":"25","author":"Wennerberg A","year":"2010","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.07.020"},{"key":"e_1_2_6_24_2","first-page":"536","article-title":"Oral implant surfaces: Part 1 \u2013 review focusing on topographic and chemical properties of different surfaces and in vivo responses to them","volume":"17","author":"Albrektsson T","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_25_2","unstructured":"WennerbergA.On surface roughness and implant incorporation. PhD thesis Dept of Biomaterails\/Handicap research University of Gothernburg Sweden 1995:1\u2013212."},{"issue":"1","key":"e_1_2_6_26_2","first-page":"e95","article-title":"Clinical experience of TiUnite implants: a 5\u2010year cross\u2010sectional, retrospective follow\u2010up study","volume":"12","author":"Friberg B","year":"2010","journal-title":"Clin Implant Dent Relat Res"},{"key":"e_1_2_6_27_2","first-page":"1113","article-title":"A retrospective study of the survival of smooth\u2010 and rough\u2010surface dental implants","volume":"24","author":"Balshe AA","year":"2009","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_6_28_2","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1111\/j.1600-051X.2004.00568.x","article-title":"Oral rehabilitation with implant\u2010supported fixed partial dentures in peridontitis\u2010susceptible subjects. A 5\u2010year prospective study","volume":"31","author":"Wennstr\u00f6m J","year":"2004","journal-title":"J Clin Periodontol"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00016.x"},{"key":"e_1_2_6_30_2","first-page":"315","article-title":"Immediate occlusal loading of implants in the partially edentate mandible: a prospective 1\u2010year radiographic and 4\u2010year clinical study","volume":"23","author":"\u00d6stman PO","year":"2008","journal-title":"Int J Oral Maxillofac Implants"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1708-8208.2011.00437.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1708-8208.2011.00437.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T15:57:39Z","timestamp":1696348659000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1708-8208.2011.00437.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1,17]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["10.1111\/j.1708-8208.2011.00437.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1708-8208.2011.00437.x","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,1,17]]}}}