{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T03:07:39Z","timestamp":1772766459563,"version":"3.50.1"},"reference-count":33,"publisher":"Wiley","issue":"s1","license":[{"start":{"date-parts":[[2012,4,5]],"date-time":"2012-04-05T00:00:00Z","timestamp":1333584000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Implant Dent Rel Res"],"published-print":{"date-parts":[[2012,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p><jats:bold>Background:<\/jats:bold>Various designs of dental implants representing different geometries and surface technologies are commercially available and clinically used in patients. However, data with regard to bone tissue responses and stability for comparison of their biologic performances are rare.<\/jats:p><jats:p><jats:bold>Purpose:<\/jats:bold>The aim of the present experimental investigation was to compare the bone tissue responses and implant stability between two commonly used dental implants representing different geometries and surface characteristics.<\/jats:p><jats:p><jats:bold>Materials and Methods:<\/jats:bold>A total of 90 dental implants (4.3\u2003mm in diameter, 10\u2003mm long) with an oxidized surface (Replace Select Tapered, TiUnite, Nobel Biocare AB, Gothenburg, Sweden) (OX) and 90 implants (4.1\u2003mm in diameter, 10\u2003mm total length) with a hydrophilic sand\u2010blasted and acid etched surface (Standard Plus, SLActive, Institut Straumann AG, Basel, Switzerland) (HSBA) were placed in the distal femur (<jats:italic>n<\/jats:italic>\u2003=\u20031) and tibia (<jats:italic>n<\/jats:italic>\u2003=\u20032) of 30 rabbits. The implants were analyzed with implant stability quotient (ISQ) measurements, removal torque (RTQ) and histomorphometry (bone\u2013implant contact, BIC) after 10 days, 3, and 6 weeks. Moreover, RTQ values were corrected for differences in surface area by calculating the shear strength for each implant.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold>RTQ and ISQ measurements showed an increase with time for both implant types. A significantly higher RTQ value was observed for the HSBA implant at 3 weeks (<jats:italic>p<\/jats:italic>\u2003=\u2003.05). A lower ISQ value was seen for HSBA than for OX implants at placement in the tibia (<jats:italic>p<\/jats:italic>\u2003&lt;\u20030.001). HSBA implants showed higher shear strength values than OX implants after 3 weeks (<jats:italic>p<\/jats:italic>\u2003&lt;\u2003.001), and 6 weeks (<jats:italic>p<\/jats:italic>\u2003&lt;\u2003.01). The morphometric measurements showed significantly higher BIC for HSBA implants after 10 days (<jats:italic>p<\/jats:italic>\u2003&lt;\u2003.01), similar values after 3 weeks and significantly higher BIC for OX implants after 6 weeks (<jats:italic>p<\/jats:italic>\u2003&lt;\u2003.001).<\/jats:p><jats:p><jats:bold>Conclusions:<\/jats:bold>Both HSBA and OX implants were well integrated in bone and showed firm and increased stability from placement to after 6 weeks of healing. The HSBA implant showed more BIC after 10 days and the OX implant more BIC after 6 weeks of healing. The HSBA implant showed significantly higher shear strength after 3 and 6 weeks and higher RTQ values after 3 weeks than the OX implant. The results may be due to differences in surface roughness and hydrophilic properties.<\/jats:p>","DOI":"10.1111\/j.1708-8208.2012.00439.x","type":"journal-article","created":{"date-parts":[[2012,4,5]],"date-time":"2012-04-05T20:58:13Z","timestamp":1333659493000},"source":"Crossref","is-referenced-by-count":44,"title":["An Experimental Comparison of Two Different Clinically Used Implant Designs and Surfaces"],"prefix":"10.1111","volume":"14","author":[{"given":"Jan","family":"Gottlow","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sargon","family":"Barkarmo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars","family":"Sennerby","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,4,5]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"536","article-title":"Oral implant surfaces: part 1 \u2013 review focusing on topographic and chemical properties of different surfaces and in vivo responses to them","volume":"17","author":"Albektsson T","year":"2004","journal-title":"Int J Prosthodont"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1834-7819.2008.00038.x"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2000.tb00110.x"},{"key":"e_1_2_6_5_2","first-page":"111","volume-title":"Dental implants: materials and systems","author":"Osborn JF","year":"1980"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/j.0022-0337.2003.67.8.tb03681.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2003.140203.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2001.012002128.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2007.00074.x"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1177\/154405910408300704"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2007.070157"},{"key":"e_1_2_6_12_2","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1111\/j.1600-051X.2007.01159.x","article-title":"Bone regeneration in dehiscence\u2010type defects at non\u2010submerged and submerged chemically modified (SLActive) and conventional SLA titanium implants: an immunohistochemical study in dogs","volume":"35","author":"Schwarz F","year":"2008","journal-title":"J Clin Periodontol"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2009.03.662"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2008.01651.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(07)60003-1"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2008.00096.x"},{"key":"e_1_2_6_17_2","first-page":"325","article-title":"Technique for placement of oxidized titanium implants in compromised maxillary bone: prospective study of 290 implants in 126 consecutive patients followed for a minimum of 3 years after loading","volume":"24","author":"Bahat O","year":"2009","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2008.01626.x"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2010.090727"},{"key":"e_1_2_6_20_2","doi-asserted-by":"crossref","first-page":"59","DOI":"10.2147\/CCIDE.S15949","article-title":"Current knowledge about the hydrophilic and nanostructured SLActive surface","volume":"3","author":"Wennerberg A","year":"2011","journal-title":"Clin Cosmetic Inv Dent"},{"key":"e_1_2_6_21_2","first-page":"5","article-title":"Properties of a new porous oxide surface on titanium implants","volume":"1","author":"Hall J","year":"2000","journal-title":"Appl Osseointegration Res"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0901-5027(05)80837-9"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0901-5027(96)80036-1"},{"key":"e_1_2_6_24_2","first-page":"631","article-title":"Surface characteristics of electrochemically oxidized implants and acid\u2010etched implants: surface chemistry, prophology, pore configurations, oxide thickness, crystal structure and roughness","volume":"23","author":"Sul YT","year":"2008","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0757.2008.00267.x"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820250708"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2004.tb00213.x"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2004.01028.x"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2001.tb00142.x"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00015.x"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00016.x"},{"key":"e_1_2_6_32_2","first-page":"315","article-title":"Immediate occlusal loading of implants in the partially edentate mandible: a prospective 1\u2010year radiographic and 4\u2010year clinical study","volume":"23","author":"Ostman PO","year":"2008","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2005.tb00079.x"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2010.02050.x"}],"container-title":["Clinical Implant Dentistry and Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1708-8208.2012.00439.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1708-8208.2012.00439.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T21:48:16Z","timestamp":1713822496000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1708-8208.2012.00439.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,4,5]]},"references-count":33,"journal-issue":{"issue":"s1","published-print":{"date-parts":[[2012,5]]}},"alternative-id":["10.1111\/j.1708-8208.2012.00439.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1708-8208.2012.00439.x","archive":["Portico"],"relation":{},"ISSN":["1523-0899","1708-8208"],"issn-type":[{"value":"1523-0899","type":"print"},{"value":"1708-8208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,4,5]]}}}