{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T20:35:15Z","timestamp":1793824515612,"version":"4.6.1"},"reference-count":28,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2009,10,26]],"date-time":"2009-10-26T00:00:00Z","timestamp":1256515200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Radiology Ultrasound"],"published-print":{"date-parts":[[2009,11]]},"abstract":"<jats:p>The purpose of this study was to describe relevant canine brain structures as seen on T2\u2010weighted images following magnetic resonance (MR) imaging at 7\u2003T and to compare the results with imaging at 1.5\u2003T. Imaging was performed on five healthy laboratory beagle dogs using 1.5 and 7\u2003T clinical scanners. At 1.5\u2003T, spin echo images were acquired, while gradient echo images were acquired at 3\u2003T. Image quality and conspicuity of anatomic structures were evaluated qualitatively by direct comparison of the images obtained from the two different magnetic fields. The signal\u2010to\u2010nose ratio (SNR) and contrast\u2010to\u2010noise ratio (CNR) were calculated and compared between 1.5 and 7\u2003T. The T2\u2010weighted images at 7\u2003T provided good spatial and contrast resolution for the identification of clinically relevant brain anatomy; these images provided better delineation and conspicuity of the brain stem and cerebellar structures, which were difficult to unequivocally identify at 1.5\u2003T. However, frontal and parietal lobe and the trigeminal nerve were difficult to identify at 7\u2003T due to susceptibility artifact. The SNR and CNR of the images at 7\u2003T were significantly increased up to 318% and 715% compared with the 1.5\u2003T images. If some disadvantages of 7\u2003T imaging, such as susceptibility artifacts, technical difficulties, and high cost, can be improved, 7\u2003T clinical MR imaging could provide a good experimental and diagnostic tool for the evaluation of canine brain disorders.<\/jats:p>","DOI":"10.1111\/j.1740-8261.2009.01591.x","type":"journal-article","created":{"date-parts":[[2009,10,26]],"date-time":"2009-10-26T14:25:00Z","timestamp":1256567100000},"page":"615-621","source":"Crossref","is-referenced-by-count":30,"title":["MAGNETIC RESONANCE IMAGING OF THE CANINE BRAIN AT 7\u2003T"],"prefix":"10.1111","volume":"50","author":[{"given":"BYEONG\u2010TECK","family":"KANG","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KI\u2010JIN","family":"KO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DONG\u2010PYO","family":"JANG","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JAE\u2010YONG","family":"HAN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"CHAE\u2010YOUNG","family":"LIM","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"CHUL","family":"PARK","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JONG\u2010HYUN","family":"YOO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JU\u2010WON","family":"KIM","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DONG\u2010IN","family":"JUNG","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"YOUNG\u2010BO","family":"KIM","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"EUNG\u2010JE","family":"WOO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ZANG\u2010HEE","family":"CHO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"HEE\u2010MYUNG","family":"PARK","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,10,26]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.0610821104"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.2006.00135.x"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/69317841"},{"key":"e_1_2_6_5_2","first-page":"e1812","article-title":"Magnetic resonance imaging of neonatal encephalopathy at 4.7 tesla","volume":"118","author":"De Vita E","year":"2006","journal-title":"initial experiences"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0b013e31817e9b2c"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/hipo.20487"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.2003.tb00504.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2008.01.069"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-007-0095-x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-7216-6706-5.00002-0"},{"key":"e_1_2_6_12_2","volume-title":"Miller's anatomy of the dog","author":"Evans HE.","year":"1993"},{"key":"e_1_2_6_13_2","volume-title":"MRI and CT Atlas of the dog","author":"Assheuer J","year":"1997"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.1989.tb00767.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.2008.00336.x"},{"key":"e_1_2_6_16_2","volume-title":"Magnetic resonance imaging","author":"Stark DD","year":"1999"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910320309"},{"key":"e_1_2_6_18_2","first-page":"10","article-title":"Imaging of brain iron by magnetic resonance","volume":"134","author":"Schenck JF.","year":"1995","journal-title":"T2 relaxation at different field strengths"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/WCO.0b013e3283168df0"},{"key":"e_1_2_6_20_2","first-page":"266","article-title":"Cerebral white matter","volume":"1142","author":"Schmahmann JD","year":"2008","journal-title":"neuroanatomy, clinical neurology, and neurobehavioral correlates"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.nlm.2007.01.001"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0197-4580(98)00084-0"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.1339-04.2004"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1471-4159.2002.00969.x"},{"key":"e_1_2_6_25_2","first-page":"521","article-title":"Ischaemic stroke in dogs and humans","volume":"46","author":"Garosi LS","year":"2005","journal-title":"a comparative review"},{"key":"e_1_2_6_26_2","first-page":"24","article-title":"7\u2003T vs. 4\u2003T","volume":"46","author":"Vaughan JT","year":"2001","journal-title":"RF power, homogeneity, and signal-to-noise comparison in head images"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21073"},{"key":"e_1_2_6_28_2","first-page":"415","article-title":"3\u2003T MRI","volume":"67","author":"Alvarez\u2010Linera J.","year":"2008","journal-title":"advances in brain imaging"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002142-199902000-00004"}],"container-title":["Veterinary Radiology &amp; Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1740-8261.2009.01591.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1740-8261.2009.01591.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T23:23:55Z","timestamp":1697498635000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1740-8261.2009.01591.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,10,26]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2009,11]]}},"alternative-id":["10.1111\/j.1740-8261.2009.01591.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1740-8261.2009.01591.x","archive":["Portico"],"relation":{},"ISSN":["1058-8183","1740-8261"],"issn-type":[{"value":"1058-8183","type":"print"},{"value":"1740-8261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,10,26]]}}}