{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T02:09:41Z","timestamp":1777514981076,"version":"3.51.4"},"reference-count":29,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2010,1,4]],"date-time":"2010-01-04T00:00:00Z","timestamp":1262563200000},"content-version":"vor","delay-in-days":3,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Radiology Ultrasound"],"published-print":{"date-parts":[[2010,1]]},"abstract":"<jats:p>Intensity\u2010modulated radiation therapy (IMRT) can be employed to yield precise dose distributions that tightly conform to targets and reduce high doses to normal structures by generating steep dose gradients. Because of these sharp gradients, daily setup variations may have an adverse effect on clinical outcome such that an adjacent normal structure may be overdosed and\/or the target may be underdosed. This study provides a detailed analysis of the impact of daily setup variations on optimized IMRT canine nasal tumor treatment plans when variations are not accounted for due to the lack of image guidance. Setup histories of ten patients with nasal tumors previously treated using helical tomotherapy were replanned retrospectively to study the impact of daily setup variations on IMRT dose distributions. Daily setup shifts were applied to IMRT plans on a fraction\u2010by\u2010fraction basis. Using mattress immobilization and laser alignment, mean setup error magnitude in any single dimension was at least 2.5\u2003mm (0\u201310.0\u2003mm). With inclusions of all three translational coordinates, mean composite offset vector was 5.9\u00b13.3\u2003mm. Due to variations, a loss of equivalent uniform dose for target volumes of up to 5.6% was noted which corresponded to a potential loss in tumor control probability of 39.5%. Overdosing of eyes and brain was noted by increases in mean normalized total dose and highest normalized dose given to 2% of the volume. Findings suggest that successful implementation of canine nasal IMRT requires daily image guidance to ensure accurate delivery of precise IMRT distributions when non\u2010rigid immobilization techniques are utilized. Unrecognized geographical misses may result in tumor recurrence and\/or radiation toxicities to the eyes and brain.<\/jats:p>","DOI":"10.1111\/j.1740-8261.2009.01629.x","type":"journal-article","created":{"date-parts":[[2010,1,5]],"date-time":"2010-01-05T00:17:35Z","timestamp":1262650655000},"page":"90-96","source":"Crossref","is-referenced-by-count":19,"title":["DOSIMETRIC IMPACT OF DAILY SETUP VARIATIONS DURING TREATMENT OF CANINE NASAL TUMORS USING INTENSITY\u2010MODULATED RADIATION THERAPY"],"prefix":"10.1111","volume":"51","author":[{"given":"MICHAEL A.","family":"DEVEAU","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ALONSO N.","family":"GUTI\u00c9RREZ","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"THOMAS R.","family":"MACKIE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"WOLFGANG A.","family":"TOM\u00c9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LISA J.","family":"FORREST","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,1,4]]},"reference":[{"key":"e_1_2_7_2_2","first-page":"126","article-title":"Spatial accuracy of fractionated IMRT delivery studies in canine paraspinal irradiation","volume":"34","author":"Kippenes H","year":"1993","journal-title":"Vet Radiol Ultrasound"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.2007.00282.x"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.07.796"},{"key":"e_1_2_7_5_2","first-page":"R363","article-title":"IMRT","volume":"51","author":"Bortfeld T.","year":"2006","journal-title":"a review and preview"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/cncr.21284"},{"key":"e_1_2_7_7_2","first-page":"199","article-title":"Dose\u2010volume specification","volume":"12","author":"Purdy JA.","year":"2002","journal-title":"new challenges with intensity-modulated radiation therapy"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(03)00090-7"},{"key":"e_1_2_7_9_2","unstructured":"ICRU.Prescribing recording and reporting photon beam therapy. ICRU report no. 50 Bethesda MD.1993"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0167-8140(88)90167-3"},{"key":"e_1_2_7_11_2","first-page":"465","article-title":"Clinical implementation of adaptive helical tomotherapy","volume":"5","author":"Welsh JS","year":"2006","journal-title":"a unique approach to image-guided intensity modulated radiotherapy"},{"key":"e_1_2_7_12_2","first-page":"1","article-title":"Intensity\u2010modulated radiotherapy of head\u2010and\u2010neck cancer","volume":"53","author":"Eisbruch A.","year":"2002","journal-title":"encouraging early results"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2004.07.696"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(93)90257-V"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2005.02.029"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(01)01740-0"},{"key":"e_1_2_7_17_2","first-page":"303","article-title":"Systematic set\u2010up errors in IMRT in the head and neck region","volume":"66","author":"Samuelsson A","year":"2003","journal-title":"effect on dose distribution"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.2000.tb02090.x"},{"key":"e_1_2_7_19_2","first-page":"476","article-title":"A vacuum\u2010formable mattress for veterinary radiotherapy positioning","volume":"44","author":"Green EM","year":"2003","journal-title":"comparison with conventional methods"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.2003.tb00487.x"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.1998.tb01637.x"},{"key":"e_1_2_7_22_2","first-page":"103","article-title":"Reporting and analyzing dose distributions","volume":"24","author":"Niemierko A.","year":"1997","journal-title":"a concept of equivalent uniform dose"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/0167-8140(92)90244-O"},{"key":"e_1_2_7_24_2","first-page":"45","article-title":"The simultaneous boost technique","volume":"22","author":"Lebesque JV","year":"1991","journal-title":"the concept of relative normalized total dose"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1740-8261.2007.00304.x"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1118\/1.2826558"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1118\/1.1485060"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(97)00055-2"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(00)00502-2"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(01)00414-5"}],"container-title":["Veterinary Radiology &amp; Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1740-8261.2009.01629.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1740-8261.2009.01629.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T13:23:11Z","timestamp":1697289791000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1740-8261.2009.01629.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["10.1111\/j.1740-8261.2009.01629.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1740-8261.2009.01629.x","archive":["Portico"],"relation":{},"ISSN":["1058-8183","1740-8261"],"issn-type":[{"value":"1058-8183","type":"print"},{"value":"1740-8261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1]]}}}