{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T09:41:28Z","timestamp":1773308488427,"version":"3.50.1"},"reference-count":28,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2011,3,17]],"date-time":"2011-03-17T00:00:00Z","timestamp":1300320000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Lab Hematology"],"published-print":{"date-parts":[[2011,10]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p><jats:bold>Introduction:\u2002<\/jats:bold> The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near\u2010infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in patients with difficult or small veins, such as children. This study was aimed to evaluate whether a transillumination device can advantageously replace the use of the tourniquet during the procedure for collection of blood specimens for RHT and thereby eliminating the discomfort and risk of spurious results caused by excessive or prolonged venous stasis.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Two hundred and fifty volunteers were divided into five groups (G1, G2, G3, G4 and G5) to compare the results of RHT between blood sample collected with transilluminator device (left arm) and with tourniquet application (right arm) for 30\u2003s(G1), 60\u2003s(G2), 90\u2003s(G3), 120\u2003s(G4) and 180\u2003s(G5).<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> No significant increases were observed in any of the haematological parameters tested in G1 when compared with blood collected by the transilluminator device. From G2 to G5, significant increases were observed for the platelet count, red blood cell count, haemoglobin, haematocrit, white blood cell count, neutrophils, monocytes and eosinophils. From G3\u2013G5, further increases were observed for lymphocytes. Clinically significant variations were, however, observed for basophils in G2; red blood cell count, haemoglobin, haematocrit and basophils in G3 and eosinophils in G3 only.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> As such, considering that inappropriate use of the tourniquet is commonplace, we conclude that transillumination devices can represent a suitable tool to eliminate the venous stasis and to improve the quality of phlebotomy procedures.<\/jats:p>","DOI":"10.1111\/j.1751-553x.2011.01305.x","type":"journal-article","created":{"date-parts":[[2011,3,18]],"date-time":"2011-03-18T03:00:41Z","timestamp":1300417241000},"page":"457-462","source":"Crossref","is-referenced-by-count":32,"title":["Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing"],"prefix":"10.1111","volume":"33","author":[{"given":"G.","family":"LIMA\u2010OLIVEIRA","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"LIPPI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. L.","family":"SALVAGNO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"MONTAGNANA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"SCARTEZINI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. C.","family":"GUIDI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"PICHETH","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,3,17]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-553X.2009.01160.x"},{"key":"e_1_2_7_3_1","volume-title":"Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture","author":"CLSI","year":"2007"},{"key":"e_1_2_7_4_1","volume-title":"Procedures for the Handling and Processing of Blood Specimens for Common Laboratory Tests","author":"CLSI","year":"2010"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006565-200104000-00013"},{"key":"e_1_2_7_6_1","volume-title":"Diagnostic Samples: From the Patient to the Laboratory: the Impact of Preanalytical Variables on the Quality of Laboratory Results","author":"Guder W.G.","year":"2009"},{"key":"e_1_2_7_7_1","article-title":"Benefits and risks of red blood cell transfusion in pediatric patients undergoing cardiac surgery","author":"Guzzetta N.A.","year":"2010","journal-title":"Paediatric Anaesthesia"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1148\/116.3.734"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.blre.2010.09.002"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2141.2009.07600.x"},{"key":"e_1_2_7_11_1","first-page":"37","article-title":"The effects of tourniquet application vs. subcutaneous tissue transilluminator device in blood sample collection on hematological parameters. Award Recipient at the XXth ISLH Symposium","volume":"29","author":"Lima\u2010Oliveira G.S.","year":"2007","journal-title":"International Journal of Laboratory Hematology"},{"issue":"6","key":"e_1_2_7_12_1","first-page":"123","article-title":"The effects of tourniquet application during 1\u2003minute versus subcutaneous tissue transilluminator device in blood sample collection on biochemical parameters","volume":"53","author":"Lima\u2010Oliveira G.S.","year":"2007","journal-title":"Clinical Chemistry"},{"issue":"6","key":"e_1_2_7_13_1","first-page":"205","article-title":"Phlebotomists performance during blood sample collection in public and private clinical laboratories in s\u00e3o paulo city, Brazil","volume":"53","author":"Lima\u2010Oliveira G.S.","year":"2007","journal-title":"Clinical Chemistry"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1590\/S1676-24442009000600002"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1515\/CCLM.2005.146"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.mbc.0000178828.59866.03"},{"key":"e_1_2_7_17_1","first-page":"217","article-title":"Phlebotomy issues and quality improvement in results of laboratory testing","volume":"52","author":"Lippi G.","year":"2006","journal-title":"Clinical Laboratory"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2257.2006.00818.x"},{"key":"e_1_2_7_19_1","first-page":"94","article-title":"Influence of a light meal on routine haematological tests","volume":"8","author":"Lippi G.","year":"2010","journal-title":"Blood Transfusion"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cca.2010.10.022"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3181844677"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0736-4679(00)00314-0"},{"key":"e_1_2_7_23_1","doi-asserted-by":"crossref","first-page":"56","DOI":"10.55460\/YIEG-FXLT","article-title":"Tourniquets for the control of traumatic hemorrhage: a review of the literature","volume":"9","author":"Richey S.L.","year":"2009","journal-title":"Journal of Special Operations Medicine"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1080\/00365519950185229"},{"key":"e_1_2_7_25_1","first-page":"646","article-title":"[EDTA\u2010dependent pseudothrombocytopenia: clinical aspects and laboratory tests]","volume":"53","author":"Saigo K.","year":"2005","journal-title":"Rinsho Byori"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.CCM.0000259538.02375.A5"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1742-1241.2008.01981.x"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1524-4725.1998.tb04186.x"},{"key":"e_1_2_7_29_1","volume-title":"Effects of Preanalytical Variables on Clinical Laboratory Tests","author":"Young D.S.","year":"2007"}],"container-title":["International Journal of Laboratory Hematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1751-553X.2011.01305.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1751-553X.2011.01305.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T22:11:16Z","timestamp":1697321476000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1751-553X.2011.01305.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3,17]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["10.1111\/j.1751-553X.2011.01305.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1751-553x.2011.01305.x","archive":["Portico"],"relation":{},"ISSN":["1751-5521","1751-553X"],"issn-type":[{"value":"1751-5521","type":"print"},{"value":"1751-553X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,3,17]]}}}