{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T23:16:24Z","timestamp":1794093384961,"version":"4.8.0"},"reference-count":21,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2012,6,14]],"date-time":"2012-06-14T00:00:00Z","timestamp":1339632000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":1174,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["wiley.com"],"crossmark-restriction":true},"short-container-title":["Int J Lab Hematology"],"published-print":{"date-parts":[[2012,12]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p><jats:bold>Introduction:\u00a0<\/jats:bold> The diagnosis of thrombotic microangiopathies (TMA) or disorders that may mimic their features remains difficult. Mechanical hemolytic anemia with the detection of shistocytes on the blood smear is a cornerstone finding to assess the diagnosis, but microscopic evaluation of shistocytes is still problematic with wide interobserver variations. Some of the latest generation automated blood cell counters (ABCC) propose an original quantitative approach of fragmented red cells (FRC), aiming to be equivalent to the microscopic count. This parameter has been poorly evaluated.<\/jats:p><jats:p><jats:bold>Methods:\u00a0<\/jats:bold> To assess the predictive value (PV) of this test, we conducted studies comparing automated and microscopic counts of FRC\/schistocytes, based on the analysis of thousands samples in four university hospitals and using the 2 ABCC currently available (Siemens ADVIA series, Sysmex XE\u20102100).<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Reference range for FRC was &lt;0.3% for the ADVIA and &lt;0.5% for the XE\u20102100. The presence of FRC below a threshold determined at 1% (ADVIA and XE\u20102100) had a negative PV close to 100% to exclude the presence of schistocyte on the blood smear, but in relationship with a poor PV value.<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> Our study validated the utility of the immediately available FRC parameter on ABCC to exclude schistocytes and the diagnosis of TMA.<\/jats:p>","DOI":"10.1111\/j.1751-553x.2012.01434.x","type":"journal-article","created":{"date-parts":[[2012,6,14]],"date-time":"2012-06-14T05:55:06Z","timestamp":1339653306000},"page":"566-576","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Fragmented red blood cells automated measurement is a useful parameter to exclude schistocytes on the blood film"],"prefix":"10.1111","volume":"34","author":[{"given":"J.\u2010F.","family":"Lesesve","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Asnafi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Braun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Zini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,6,14]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1309\/EK3C7CTDKNVPXVTN"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-553X.2011.01380.x"},{"key":"e_1_2_7_4_2","first-page":"505","article-title":"Role du biologiste confront\u00e9\u00e0 la recherche de schizocytes. Texte de synth\u00e8se et de recommendations du Groupe Fran\u00e7ais d\u2019H\u00e9matologie Cellulaire","volume":"61","author":"Lesesve JF","year":"2003","journal-title":"Annales de Biologie Clinique"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-553X.2010.01292.x"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1309\/0GLP-K5NU-N1GD-PR8T"},{"key":"e_1_2_7_7_2","first-page":"167","article-title":"Quantification of red blood cell fragmentation by automated hematology analyser XE\u20102100","volume":"23","author":"Jiang M","year":"2001","journal-title":"Clin Lab Med"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-553X.2006.00829.x"},{"key":"e_1_2_7_9_2","unstructured":"GarziaM Di MarioA RossiE MassiniG BellesiS d\u2019OnofrioG ZiniGAutomated screening for schistocytes with two hematology analyzers. XVIII International ISLH Symposium.2005 Abstract n\u00b0A\u201086."},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-5877(00)00115-X"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2010-07-271445"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2009-09-243790"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1309\/MY7077989KWDYP88"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1532\/LH96.04064"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1309\/AJCPJRH1I0XTNFGA"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2257.2005.00704.x"},{"key":"e_1_2_7_17_2","first-page":"347","article-title":"Usefulness of automated detection of fragmented red cells using an hematology analyzer for diagnosis of thrombotic microangiopathy","volume":"24","author":"Saigo K","year":"2002","journal-title":"Clin Lab Med"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/1076029608319879"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bmt.1704601"},{"key":"e_1_2_7_20_2","first-page":"135","article-title":"Spherocytes, irregularly contracted cells or schistocytes?","volume":"24","author":"Lesesve JF","year":"2002","journal-title":"Clin Lab Med"},{"key":"e_1_2_7_21_2","first-page":"81","article-title":"Clinical utility of new parameters provided by XE\u20102100 RET channel","volume":"17","author":"Saigo K","year":"2007","journal-title":"Sys J Int"},{"key":"e_1_2_7_22_2","first-page":"303","article-title":"[Markedly increased red cell fragmentations counted as platelets in a patient with thrombotic microangiopathy]","volume":"53","author":"Wada H","year":"2005","journal-title":"Rinsho Byori"}],"container-title":["International Journal of Laboratory Hematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1751-553X.2012.01434.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1751-553X.2012.01434.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1751-553X.2012.01434.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T22:16:00Z","timestamp":1698704160000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1751-553X.2012.01434.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6,14]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["10.1111\/j.1751-553X.2012.01434.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1751-553x.2012.01434.x","archive":["Portico"],"relation":{},"ISSN":["1751-5521","1751-553X"],"issn-type":[{"value":"1751-5521","type":"print"},{"value":"1751-553X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6,14]]}}}