{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T18:46:41Z","timestamp":1791139601366,"version":"4.1.0"},"reference-count":30,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2012,1,23]],"date-time":"2012-01-23T00:00:00Z","timestamp":1327276800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J of Clinical Hypertension"],"published-print":{"date-parts":[[2012,3]]},"abstract":"<jats:p><jats:italic>J Clin Hypertens (Greenwich)<\/jats:italic>. 2012;14:139\u2013143. \u00a92012 Wiley Periodicals, Inc.<\/jats:p><jats:p>Self blood pressure measurement (SBPM) improves the overall management of hypertension provided it is implemented with methodologic care. This concerns especially the accuracy and technical requirements of blood pressure (BP) measuring devices that should be validated according to internationally accepted protocols. The use of memory\u2010equipped automatic home monitors is strongly recommended because they reduce observer bias, avoid patients\u2019 misreporting, and allow fully automatic analysis by software. For current use, simple software should be worked out that allow for analysis of readings in an objective manner. Miscuffing is also a frequent source of measurement error in obese arms when oscillometric devices are used. Modern automatic devices can overcome this problem because of special software algorithms that can provide accurate measurements over a wide range of arm circumferences when coupled with a single cuff of standard dimensions. Tronco\u2010conical\u2013shaped cuffs are a key component of this instrumentation because they better fit on large conical arms frequently present in obese individuals. Semi\u2010rigid cuffs should be increasingly used because they ensure that the proper amount of tension is applied without the intervention of the user. Continuous technology improvement of instrumentation for SBPM can be achieved through close cooperation between manufacturers and validation centers.<\/jats:p>","DOI":"10.1111\/j.1751-7176.2011.00586.x","type":"journal-article","created":{"date-parts":[[2012,1,23]],"date-time":"2012-01-23T12:14:48Z","timestamp":1327320888000},"page":"139-143","source":"Crossref","is-referenced-by-count":22,"title":["Techniques for Self\u2010Measurement of Blood Pressure: Limitations and Needs for Future Research"],"prefix":"10.1111","volume":"14","author":[{"given":"Paolo","family":"Palatini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerhard N.","family":"Frick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,1,23]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-200305000-00001"},{"key":"e_1_2_8_3_2","first-page":"255","article-title":"How common is white coat hypertension?","volume":"259","author":"Pickering TG","year":"1988","journal-title":"JAMA"},{"key":"e_1_2_8_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200112000-00005"},{"key":"e_1_2_8_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.0000150859.47929.8e"},{"key":"e_1_2_8_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.111.184184"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e328308da66"},{"key":"e_1_2_8_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200106000-00005"},{"key":"e_1_2_8_9_2","volume-title":"European Standard EN 1060\u20103 1997 (British Standard BSEN 1060\u20103: 1997). Specification for Noninvasive Sphygmomanometers. Part 3. Supplementary Requirements for Electro\u2010Mechanical Blood Pressure Measuring Systems","author":"European Committee for Standardization","year":"1997"},{"key":"e_1_2_8_10_2","volume-title":"American National Standard for Electronic or Automated Sphygmomanometers: ANSI\/AAMI SP10\u20101993","author":"Association for the Advancement of Medical Instrumentation","year":"1993"},{"issue":"2","key":"e_1_2_8_11_2","first-page":"S43","article-title":"The British Hypertension Society protocol for the evaluation of blood pressure measuring devices","volume":"11","author":"O\u2019Brien E","year":"1993","journal-title":"J Hypertens"},{"key":"e_1_2_8_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200202000-00002"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283360e98"},{"key":"e_1_2_8_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283057ad0"},{"key":"e_1_2_8_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0895-7061(98)00241-6"},{"key":"e_1_2_8_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.107.104620"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e3283260681"},{"key":"e_1_2_8_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e32809efa38"},{"key":"e_1_2_8_19_2","first-page":"565","article-title":"A century of confusion: which bladder for accurate blood pressure measurement?","volume":"10","author":"O\u2019Brien E","year":"1996","journal-title":"J Hum Hypertens"},{"key":"e_1_2_8_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e3283435b65"},{"key":"e_1_2_8_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200006000-00001"},{"key":"e_1_2_8_22_2","first-page":"87","article-title":"Reliability of blood pressure measurement on fat upper arms","volume":"39","author":"Huige MC","year":"1982","journal-title":"Ther Umsch"},{"key":"e_1_2_8_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/ije\/14.3.468"},{"key":"e_1_2_8_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jopan.2011.02.001"},{"key":"e_1_2_8_25_2","article-title":"Rectangular cuffs may overestimate blood pressure in subjects with large conical arms","author":"Palatini P","journal-title":"J Hypertens"},{"key":"e_1_2_8_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e32834192ef"},{"key":"e_1_2_8_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e328330d3f8"},{"key":"e_1_2_8_28_2","doi-asserted-by":"publisher","DOI":"10.1038\/jhh.2008.70"},{"key":"e_1_2_8_29_2","doi-asserted-by":"publisher","DOI":"10.1038\/hr.2010.146"},{"key":"e_1_2_8_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2011.06.006"},{"key":"e_1_2_8_31_2","first-page":"344","article-title":"Hypertension in obesity","volume":"11","author":"Redon J","year":"2001","journal-title":"Nutr Metab Cardiovasc Dis."}],"container-title":["The Journal of Clinical Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1751-7176.2011.00586.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1751-7176.2011.00586.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T22:08:15Z","timestamp":1698703695000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1751-7176.2011.00586.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1,23]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,3]]}},"alternative-id":["10.1111\/j.1751-7176.2011.00586.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1751-7176.2011.00586.x","archive":["Portico"],"relation":{},"ISSN":["1524-6175","1751-7176"],"issn-type":[{"value":"1524-6175","type":"print"},{"value":"1751-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,1,23]]}}}