{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T16:55:54Z","timestamp":1758905754078},"reference-count":31,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2010,6,25]],"date-time":"2010-06-25T00:00:00Z","timestamp":1277424000000},"content-version":"vor","delay-in-days":24,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Translational Sci"],"published-print":{"date-parts":[[2010,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We evaluated the mechanical properties of a novel fiber reinforced calcium phosphate at time zero and after 12 weeks <jats:italic>in vivo<\/jats:italic> using a sheep long bone osteotomy model. Time zero data were obtained and compared by pullout testing of 4.5 mm bone screws from bone proper and overdrilled defects of 4.5 and 8 mm diameter. Defects were augmented with: polymethylmethacrylate (PMMA), calcium phosphate, and fiber reinforced calcium phosphate using cadaveric sheep tibiae. Twelve\u2010week data were obtained from explanted tibiae of sheep that underwent unilateral tibial osteotomy surgery repaired with a locking compression plate. The most distal hole was overdrilled to 4.5 or 8 mm diameter, filled with fiber reinforced cement, drilled, tapped and a 4.5 mm screw was placed. Screw holding strength at <jats:italic>t<\/jats:italic>= 0 was significantly higher for reinforced when compared to nonreinforced cement, but not different from bone or PMMA in 4.5 mm defects. There was no difference in pullout strength for the 8 mm defect data. After 12 weeks fiber reinforced pullout strength increased by 45% and 8.9% for 4.5 and 8 mm defects, respectively, when compared to <jats:italic>t<\/jats:italic>= 0 testing. Fiber reinforced calcium phosphate bone cement can be drilled and tapped to support orthopedic hardware for trauma applications. Clin Trans Sci 2010; Volume 3: 112\u2013115<\/jats:p>","DOI":"10.1111\/j.1752-8062.2010.00201.x","type":"journal-article","created":{"date-parts":[[2010,6,25]],"date-time":"2010-06-25T14:43:35Z","timestamp":1277477015000},"page":"112-115","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of a Fiber Reinforced Drillable Bone Cement for Screw Augmentation in a Sheep Model\u2014Mechanical Testing"],"prefix":"10.1111","volume":"3","author":[{"given":"Benjamin J.","family":"Ahern","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert D.","family":"Harten","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elliott A.","family":"Gruskin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas P.","family":"Schaer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,6,25]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e31816f6c73"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2007.08.014"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000290899.15567.68"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.3113\/FAI.2006.0804"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e3180616ba5"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e318033093e"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-004-0642-0"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199806150-00015"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199708010-00003"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950x.2005.00034.x"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.prs.0000178402.77445.44"},{"key":"e_1_2_7_13_2","first-page":"327","article-title":"Biomechanical evaluation of vertebroplasty using calcium sulfate cement for thoracolumbar burst fractures","volume":"10","author":"Wu X","year":"2007","journal-title":"Chin J Traumatol."},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1177\/145749690609500205"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.bsd.0000143311.70185.23"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/145749690609500206"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.2005.66.1954"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200205000-00003"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-002-0458-8"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otohns.2005.09.001"},{"key":"e_1_2_7_21_2","doi-asserted-by":"crossref","first-page":"139","DOI":"10.3928\/01477447-20060201-05","article-title":"Graft\u2010supplemented, augmented external fixation in the treatment of intra\u2010articular distal radial fractures","volume":"29","author":"Tyllianakis M","year":"2006","journal-title":"Orthopedics."},{"key":"e_1_2_7_22_2","doi-asserted-by":"crossref","first-page":"311","DOI":"10.3928\/0147-7447-20020301-14","article-title":"Use of injectable calcium phosphate in the treatment of intra\u2010articular distal radius fractures","volume":"25","author":"Tyllianakis M","year":"2002","journal-title":"Orthopedics."},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2007.05.005"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijantimicag.2006.05.024"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100140516"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199306000-00002"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-006-0127-4"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199803000-00009"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2004.09.008"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200311000-00010"},{"key":"e_1_2_7_31_2","unstructured":"ASTM Designation F 543\u201001. Standard Specification and Test Methods for Metallic Metal Bone Screws. Book of ASTM Standards. West Conshohocken PA :American Society for Testing and Materials;2001."},{"key":"e_1_2_7_32_2","unstructured":"Materials ASfTa: ASTM Designation F 543\u201001. Standard Specification and Test Methods for M etallic Metal Bone Screws. Book of ASTM Standards. West Conshohocken PA :American Society for Testing and Materials;2001."}],"container-title":["Clinical and Translational Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1752-8062.2010.00201.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/ascpt.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1752-8062.2010.00201.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T03:02:30Z","timestamp":1697425350000},"score":1,"resource":{"primary":{"URL":"https:\/\/ascpt.onlinelibrary.wiley.com\/doi\/10.1111\/j.1752-8062.2010.00201.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,6]]},"references-count":31,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,6]]}},"alternative-id":["10.1111\/j.1752-8062.2010.00201.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1752-8062.2010.00201.x","archive":["Portico"],"relation":{},"ISSN":["1752-8054","1752-8062"],"issn-type":[{"value":"1752-8054","type":"print"},{"value":"1752-8062","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,6]]}}}