{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T00:19:22Z","timestamp":1789517962422,"version":"build-2803163510"},"reference-count":26,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":1431,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011,10]]},"DOI":"10.1111\/j.1754-9485.2011.02283.x","type":"journal-article","created":{"date-parts":[[2011,10,18]],"date-time":"2011-10-18T12:59:10Z","timestamp":1318942750000},"page":"474-478","source":"Crossref","is-referenced-by-count":25,"title":["Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung"],"prefix":"10.1111","volume":"55","author":[{"given":"Megumi","family":"Nakamura","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Yoshizako","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shingo","family":"Koyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hajime","family":"Kitagaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,10,18]]},"reference":[{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB1|cit1","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1378\/chest.126.3.748","article-title":"Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies","volume":"126","author":"Yeow","year":"2004","journal-title":"Chest"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB2|cit2","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1148\/radiology.198.2.8596834","article-title":"Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung","volume":"198","author":"Kazerooni","year":"1996","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB3|cit3","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.2214\/ajr.172.4.10587145","article-title":"Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors","volume":"172","author":"Laurent","year":"1999","journal-title":"AJR"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB4|cit4","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1097\/01.RVI.0000124951.24134.50","article-title":"Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients","volume":"15","author":"Covey","year":"2004","journal-title":"J Vasc Interv Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB5|cit5","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0720-048X(03)00058-5","article-title":"Transthoracic needle biopsy: factors effecting risk of pneumothorax","volume":"48","author":"Topal","year":"2003","journal-title":"Eur J Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB6|cit6","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1148\/radiology.218.2.r01fe33491","article-title":"Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?","volume":"218","author":"Ko","year":"2001","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB7|cit7","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/S0009-9260(03)00221-6","article-title":"CT-guided lung biopsy: factors influencing diagnostic yield and complication rate","volume":"58","author":"Anderson","year":"2003","journal-title":"Clin Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB8|cit8","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1378\/chest.121.5.1521","article-title":"The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor","volume":"121","author":"Saji","year":"2002","journal-title":"Chest"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB9|cit9","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/S1051-0443(07)61556-5","article-title":"Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions","volume":"12","author":"Yeow","year":"2001","journal-title":"J Vasc Interv Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB10|cit10","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1148\/radiology.212.1.r99jl33165","article-title":"Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax","volume":"212","author":"Cox","year":"1999","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB11|cit11","doi-asserted-by":"crossref","first-page":"71","DOI":"10.2214\/ajr.150.1.71","article-title":"Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests","volume":"150","author":"Fish","year":"1988","journal-title":"AJR"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB12|cit12","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1148\/radiology.210.1.r99ja1759","article-title":"Pneumothorax and dependent versus nondependent patient position after needle biopsy of the lung","volume":"210","author":"Collings","year":"1999","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB13|cit13","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.2291020499","article-title":"CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate","volume":"229","author":"Geraghty","year":"2003","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB14|cit14","doi-asserted-by":"crossref","first-page":"1516","DOI":"10.1378\/chest.126.5.1516","article-title":"Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung","volume":"126","author":"Choi","year":"2004","journal-title":"Chest"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB15|cit15","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.ejrad.2008.01.006","article-title":"CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications","volume":"70","author":"Yildirim","year":"2009","journal-title":"Eur J Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB16|cit16","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.rmed.2008.09.010","article-title":"Risk assessment of pneumothorax and pulmonary haemorrhage complicating percutaneous co-axial cutting needle lung biopsy","volume":"103","author":"Chakrabarti","year":"2009","journal-title":"Respir Med"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB17|cit17","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1007\/s00330-008-0893-1","article-title":"Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy","volume":"18","author":"Khan","year":"2008","journal-title":"Eur Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB18|cit18","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.2214\/ajr.180.6.1801665","article-title":"CT-guided transthoracic needle aspiration biopsy of small (\u226420\u2003mm) solitary pulmonary nodules","volume":"180","author":"Ohno","year":"2003","journal-title":"AJR"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB19|cit19","doi-asserted-by":"crossref","first-page":"809","DOI":"10.2214\/AJR.09.3224","article-title":"Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period","volume":"194","author":"Hiraki","year":"2010","journal-title":"AJR"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB20|cit20","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0720-048X(01)00391-6","article-title":"Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy","volume":"42","author":"Froelich","year":"2002","journal-title":"Eur J Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB21|cit21","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/S1051-0443(07)61805-3","article-title":"Value of CT fluoroscopy for percutaneous biopsy procedures","volume":"11","author":"Gianfelice","year":"2000","journal-title":"J Vasc Interv Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB22|cit22","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1053\/crad.2001.0716","article-title":"CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial","volume":"57","author":"Kirchner","year":"2002","journal-title":"Clin Radiol"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB23|cit23","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1148\/radiology.219.2.r01ma41515","article-title":"Benefits and safety of CT fluoroscopy in interventional radiologic procedures","volume":"219","author":"Carlson","year":"2001","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB24|cit24","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1148\/radiology.144.4.7111716","article-title":"Determining the size of pneumothorax in the upright patient","volume":"144","author":"Rhea","year":"1982","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB25|cit25","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1148\/radiology.181.2.1924776","article-title":"Effect of patient positioning after needle aspiration lung biopsy","volume":"181","author":"Moore","year":"1991","journal-title":"Radiology"},{"key":"10.1111\/j.1754-9485.2011.02283.x-BIB26|cit26","doi-asserted-by":"crossref","first-page":"926","DOI":"10.2214\/AJR.05.0226","article-title":"CT-guided transthoracic needle biopsy using a puncture site-down positioning technique","volume":"187","author":"Kinoshita","year":"2006","journal-title":"AJR"}],"container-title":["Journal of Medical Imaging and Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1754-9485.2011.02283.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1111\/j.1754-9485.2011.02283.x\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,6]],"date-time":"2021-07-06T16:13:03Z","timestamp":1625587983000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1754-9485.2011.02283.x"}},"subtitle":["Risk factors influencing chest tube placement for pneumothorax because of CT-guided needle biopsy of the lung"],"short-title":[],"issued":{"date-parts":[[2011,10]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011,10]]}},"URL":"https:\/\/doi.org\/10.1111\/j.1754-9485.2011.02283.x","relation":{},"ISSN":["1754-9477"],"issn-type":[{"value":"1754-9477","type":"print"}],"subject":[],"published":{"date-parts":[[2011,10]]}}}