{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T06:53:27Z","timestamp":1774421607136,"version":"3.50.1"},"reference-count":22,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2008,9,22]],"date-time":"2008-09-22T00:00:00Z","timestamp":1222041600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2009,11]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold>We aimed to determine normal macular thickness values, assessed with optical coherence tomography (OCT)<jats:italic>,<\/jats:italic>in a population of full\u2010term children of normal birthweight.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold>A total of 56 children, aged 5\u201316\u2003years, randomly chosen from the population register, were examined with Stratus OCT. Only children with visual acuity &lt;\u20030.2 logMAR, spherical equivalent of \u2212\u20033 to +\u20033\u2003D and astigmatism &lt;\u20032\u2003D were included. The fast macular map protocol was used and three examinations were performed in each eye. One eye was then randomized for further analyses. Mean values for the nine ETDRS areas, foveal minimum thickness and macular volume were calculated for 55 eyes. Coefficients of variance and intraclass correlations were calculated for each area.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold>All children co\u2010operated well and no child was excluded for lack of concentration. Mean\u2003\u00b1\u2003standard deviation central macular thickness was 204\u2003\u00b1\u200319\u2003\u03bcm. Mean total macular volume was 7.11\u2003\u00b1\u20030.35\u2003mm<jats:sup>3<\/jats:sup>. No correlations were found between age, gender and macular thickness. Coefficients of variance were &lt;\u20032% and intraclass correlations were &gt;\u20030.9 in all areas, except the foveal minimum.<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold>Normal values for macular thickness in healthy full\u2010term children were reported. As the Stratus OCT provides normal values only for adults, these data are a better alternative for comparison with children with retinal abnormalities. We concluded that OCT is suitable for examining the retina in children aged 5\u201316\u2003years and has the same high level of repeatability as in adults.<\/jats:p>","DOI":"10.1111\/j.1755-3768.2008.01357.x","type":"journal-article","created":{"date-parts":[[2008,9,22]],"date-time":"2008-09-22T10:00:34Z","timestamp":1222077634000},"page":"741-745","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["A population\u2010based study of macular thickness in full\u2010term children assessed with Stratus OCT: normative data and repeatability"],"prefix":"10.1111","volume":"87","author":[{"given":"Urban","family":"Eriksson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerd","family":"Holmstr\u00f6m","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert","family":"Alm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eva","family":"Larsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,10,20]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.87.7.899"},{"key":"e_1_2_6_3_1","doi-asserted-by":"crossref","first-page":"216","DOI":"10.3928\/01913913-20050701-03","article-title":"Thickness of nerve fibre layer, macular thickness and macular volume in patients with strabismic amblyopia","volume":"42","author":"Altintas \u00d6","year":"2005","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"e_1_2_6_4_1","volume-title":"Manual for Stratus OCT, Model 3000","author":"Carl Zeiss Meditec AG","year":"2004"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.124.2.193"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-1199"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2004.00227.x"},{"key":"e_1_2_6_8_1","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1111\/j.1600-0420.2004.00227.x","article-title":"Optical coherence tomography in the diagnosis of juvenile X\u2010linked retinoschisis","volume":"84","author":"Eriksson U","year":"2004","journal-title":"Acta Ophthalmol Scand"},{"key":"e_1_2_6_9_1","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1001\/archopht.1995.01100080071031","article-title":"Quantitative assessment of macular oedema with optical coherence tomography","volume":"113","author":"Hee MR","year":"1995","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.10.047"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-1396"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2007.01009.x"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2007.01009.x"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1177\/112067210201200205"},{"key":"e_1_2_6_15_1","doi-asserted-by":"crossref","first-page":"159","DOI":"10.3928\/0191-3913-20040501-08","article-title":"Use of optical coherence tomography in myopia","volume":"41","author":"Mrugacz M","year":"2004","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"e_1_2_6_16_1","doi-asserted-by":"crossref","first-page":"1716","DOI":"10.1167\/iovs.03-0514","article-title":"Reproducibility of nerve fibre thickness, macular thickness and optic nerve head measurements using Stratus OCT","volume":"45","author":"Panescu LA","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_17_1","doi-asserted-by":"crossref","first-page":"1581","DOI":"10.1136\/bjo.2005.069815","article-title":"Comparison of optical coherence tomography models OCT\u20031 and Stratus OCT for macular and retinal thickness measurement","volume":"89","author":"Pierre\u2010Kahn V","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_6_18_1","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1001\/archopht.123.10.1330","article-title":"Repeatability and reproducibility of fast macular thickness mapping with Stratus optical coherence tomography","volume":"123","author":"Polito A","year":"2005","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_6_19_1","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/S0161-6420(95)31032-9","article-title":"Imaging of macular diseases with optical coherence tomography","volume":"102","author":"Puliafito CA","year":"1995","journal-title":"Ophthalmology"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.03.032"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2007.00917.x"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2007.00917.x"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.11.042"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1755-3768.2008.01357.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1755-3768.2008.01357.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,29]],"date-time":"2024-02-29T22:15:55Z","timestamp":1709244955000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1755-3768.2008.01357.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,10,20]]},"references-count":22,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2009,11]]}},"alternative-id":["10.1111\/j.1755-3768.2008.01357.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1755-3768.2008.01357.x","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,10,20]]},"assertion":[{"value":"2009-10-20","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}