{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T22:09:11Z","timestamp":1793138951165,"version":"4.5.0"},"reference-count":22,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,12,16]],"date-time":"2008-12-16T00:00:00Z","timestamp":1229385600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Ophthalmologica"],"published-print":{"date-parts":[[2010,2]]},"abstract":"<jats:title>Abstract.<\/jats:title><jats:p><jats:bold>Purpose:\u2002<\/jats:bold> This study aimed to evaluate reaction time (RT) in patients with advanced visual field (VF) loss using semi\u2010automated kinetic perimetry (SKP).<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Seventy\u2010eight patients with advanced VF loss caused by glaucoma (31) or retinitis pigmentosa (19), homonymous VF loss caused by post\u2010chiasmal lesions (18) and unilateral anterior ischaemic optic neuropathy (AION) (10) were examined with SKP (Octopus 101 perimeter). One eye in each patient was enrolled. Additionally, VFs in the 10 healthy fellow eyes of the patients with AION were compared with those in the 10 affected eyes. Reaction time was assessed during the SKP session by presenting kinetic stimuli (III4e) with constant angular velocities of 3\u2003\u00b0\/second moving linearly along so\u2010called \u2018RT vectors\u2019 at four different locations inside the III4e isoptre. Each stimulus presentation was repeated four times in randomized order.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> The geometric mean RT was 794\u2003ms (95% reference interval [RI] 391\u20131615\u2003ms) in patients with glaucoma, 702\u2003ms (95% RI 306\u20131608\u2003ms) in patients with retinitis pigmentosa and 675\u2003ms (95% RI 312\u20131460\u2003ms) in patients with hemianopia. Increases in RT for every 1\u2003\u00b0 of eccentricity were 1%, 0.9% and 0.4%, respectively. The geometric mean RT in the 10 patients with unilateral optic neuropathy was 644\u2003ms in affected eyes and 435\u2003ms in unaffected eyes, reflecting an increase of 51% (95% confidence interval 42\u201362%).<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> We found substantial inter\u2010subject variability in RT in patients with advanced VF loss. It is possible to correct the position of the isoptres by assessing individual RT. There were no relevant differences in RT between the disease groups. Reaction time increases with eccentricity. In monocular disease (AION), RT is prolonged, compared with in healthy fellow eyes. However, in clinical routine the RT\u2010related displacement of isoptres is negligible in the vast majority of cases.<\/jats:p>","DOI":"10.1111\/j.1755-3768.2008.01407.x","type":"journal-article","created":{"date-parts":[[2008,12,18]],"date-time":"2008-12-18T02:50:32Z","timestamp":1229568632000},"page":"65-69","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Reaction time during semi\u2010automated kinetic perimetry (SKP) in patients with advanced visual field loss"],"prefix":"10.1111","volume":"88","author":[{"given":"Katarzyna","family":"Nowomiejska","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinhard","family":"Vonthein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Paetzold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zbigniew","family":"Zagorski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Randy","family":"Kardon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich","family":"Schiefer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,1,28]]},"reference":[{"key":"e_1_2_7_2_1","first-page":"78","volume-title":"Testing the Field of Vision","author":"Anderson DR","year":"1982"},{"key":"e_1_2_7_3_1","first-page":"129","article-title":"Response time as a discriminator between true\u2010 and false\u2010positive responses in suprathreshold perimetry","volume":"43","author":"Artes PH","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-1413"},{"key":"e_1_2_7_5_1","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1111\/j.1600-0420.2005.00624.x","article-title":"Scotoma mapping by semi\u2010automated kinetic perimetry \u2013 the effects of stimulus properties and the speed of subjects\u2019 responses","volume":"84","author":"Dolderer J","year":"2006","journal-title":"Acta Ophthalmol"},{"key":"e_1_2_7_6_1","first-page":"14","article-title":"Studies in the reproducibility of visual field areas in normal and glaucomatous subjects","volume":"1","author":"Drance SM","year":"1966","journal-title":"Can J Ophthalmol"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1159\/000305848"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1984.01040030700022"},{"key":"e_1_2_7_9_1","first-page":"1","article-title":"Single and multiple stimulus static perimetry in glaucoma; the two phases of perimetry Thesis","volume":"36","author":"Greve EL","year":"1973","journal-title":"Doc Ophthalmol"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1987.01060010079035"},{"key":"e_1_2_7_11_1","first-page":"25","volume-title":"Perimetrie","author":"Lachenmayr BJ","year":"1992"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2004.12.047"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.1997.tb00120.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1984.01040031217021"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(66)90085-X"},{"key":"e_1_2_7_16_1","first-page":"1","article-title":"Reaction time to retinal stimulation with special reference to the time lost in conduction through nerve centers","volume":"3","author":"Poffenberger AT","year":"1912","journal-title":"Arch Psychol"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(63)90057-9"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(01)00088-8"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.09.030"},{"issue":"1","key":"e_1_2_7_20_1","first-page":"5","article-title":"Auswirkung unterschiedlicher Pr\u00fcfgeschwindigkeiten auf die Ergebnisse der kinetischen Perimetrie","volume":"99","author":"Wabbels BK","year":"1999","journal-title":"Ophthalmologe"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s003470170179"},{"key":"e_1_2_7_22_1","first-page":"878","article-title":"The psychometric function and reaction times of automated perimetry in normal and abnormal areas of the visual field in patients with glaucoma","volume":"37","author":"Wall M","year":"1996","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(01)00311-X"}],"container-title":["Acta Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1755-3768.2008.01407.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1755-3768.2008.01407.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T21:59:39Z","timestamp":1698789579000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1755-3768.2008.01407.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1,28]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,2]]}},"alternative-id":["10.1111\/j.1755-3768.2008.01407.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1755-3768.2008.01407.x","archive":["Portico"],"relation":{},"ISSN":["1755-375X","1755-3768"],"issn-type":[{"value":"1755-375X","type":"print"},{"value":"1755-3768","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1,28]]},"assertion":[{"value":"2010-01-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}